An electromyography-assisted biomechanical cervical spine model: Model development and validation

被引:6
|
作者
Alizadeh, Mina [1 ]
Aurand, Alexander [1 ]
Knapik, Gregory G. [1 ]
Dufour, Jonathan S. [1 ]
Mendel, Ehud [2 ]
Bourekas, Eric [3 ]
Marras, William S. [1 ]
机构
[1] Ohio State Univ, Spine Res Inst, 520 Baker Syst,1971 Neil Ave, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Neurol Surg, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
关键词
Computational model; Neck model; Multi-body dynamics; Curved muscle model; Occupational neck injury; HEAD-NECK MODEL; MUSCLE MODEL; MOMENT ARMS; FORCE; JOINT; IMPACT; PAIN;
D O I
10.1016/j.clinbiomech.2020.105169
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: In spite of the prevalence of occupational neck disorders as a result of work force fluctuating from industry to sedentary office work, most cervical spine computational models are not capable of simulating occupational and daily living activities whereas majority of cervical spine models specialized to simulate crash and impact scenarios. Therefore, estimating spine tissue loads accurately to quantify the risk of neck disorders in occupational environments within those models is not possible due to the lack of muscle models, dynamic simulation and passive spine structures. Methods: In this effort the structure, logic, and validation process of an electromyography-assisted cervical biomechanical model that is capable of estimating neck loading under three-dimensional complex motions is described. The developed model was designed to simulate complex dynamic motions similar to work place exposure. Curved muscle geometry, personalized muscle force parameters, and separate passive and (electromyography-driven) active muscle force components are implemented in this model. Findings: Calibration algorithms were able to reverse-engineer personalized muscle properties to calculate active and passive muscle forces of each individual. Interpretation: This electromyography-assisted cervical spine model with curved muscle model is capable to accurately predict spinal tissue loads during isometric and dynamic head and neck activities. Personalized active and passive muscle force algorithms will help to more robustly investigate person-specific muscle forces and spinal tissue loads.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] ELECTROMYOGRAPHY OF THE DIAPHRAGM IN PATIENTS WITH CERVICAL-SPINE LESIONS NECESSITATING ASSISTED VENTILATION
    LESOIN, F
    DELANDSHEER, E
    LOZES, G
    HURTEVENT, JF
    JOMIN, M
    GUIEU, JD
    LANCET, 1983, 1 (8338): : 1385 - 1386
  • [32] The importance of modal validation for biomechanical models, demonstrated by application to the cervical spine
    Meyer, F
    Willinger, R
    Legall, F
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2004, 40 (13-14) : 1835 - 1855
  • [33] A subject-specific biomechanical control model for the prediction of cervical spine muscle forces
    Van den Abbeele, Maxim
    Li, Fan
    Pomero, Vincent
    Bonneau, Dominique
    Sandoz, Baptiste
    Laporte, Sebastien
    Skalli, Wafa
    CLINICAL BIOMECHANICS, 2018, 51 : 58 - 66
  • [34] Development of a virtual model and experimental simulator for the human cervical spine
    Ahn, Hyung Soo
    DiAngelo, Denis
    Experimental Mechanics in Nano and Biotechnology, Pts 1 and 2, 2006, 326-328 : 769 - 772
  • [35] Development of a Ligamentous Finite Element Model of the Human Cervical Spine
    Tongprapai, Worakan
    Rattanapan, Nichapat
    Torudom, Yingyong
    Sukjamsri, Chamaiporn
    1ST NATIONAL BIOMEDICAL ENGINEERING CONFERENCE (NBEC 2021): ADVANCED TECHNOLOGY FOR MODERN HEALTHCARE, 2021, : 122 - 126
  • [36] A musculoskeletal model of the lumbar spine using ArtiSynth - development and validation
    Malakoutian, Masoud
    Street, John
    Wilke, Hans-Joachim
    Stavness, Ian
    Fels, Sidney
    Oxland, Thomas
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2018, 6 (05): : 483 - 490
  • [37] A dynamic finite element model of human cervical spine with in vivo kinematic validation
    Wang, Jiajia
    Qian, Zhihui
    Ren, Lei
    Ren, Luquan
    CHINESE SCIENCE BULLETIN, 2014, 59 (33): : 4578 - 4588
  • [38] Biomechanical evaluation of cervical spine fixation after healing in a destabilized cervical spine model in sheep: A comparison of the anterior plating and posterior wiring techniques
    Lee, Ming-Yang
    Chang, Guan-Liang
    Chang, Jia-Hao
    Hung, Yu-Chang
    Chang, Ching-Hong
    Lee, E-Jian
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (06): : 1307 - 1314
  • [39] Some Observations on the Biomechanical Model of the Spine.
    Rizzi, Mario A.
    Whitman, Alan B.
    De Silva, Carl N.
    Zeitschrift fuer Angewandte Mathematik und Mechanik, 1975, 55 (12): : 739 - 746
  • [40] The Biomechanical Effect of Transverse Connectors Use in a Pre- and Postlaminectomy Model of the Posterior Cervical Spine
    Majid, Kamran
    Gudipally, Manasa
    Hussain, Mir
    Moldavsky, Mark
    Khalil, Saif
    SPINE, 2011, 36 (26) : E1694 - E1701