A review on impedimetric biosensors

被引:198
|
作者
Bahadir, Elif Burcu [1 ]
Sezginturk, Mustafa Kemal [2 ]
机构
[1] Namik Kemal Univ, Sci & Technol Res Ctr, Tekirdag, Turkey
[2] Namik Kemal Univ, Dept Chem, Div Biochem, Fac Sci, Tekirdag, Turkey
关键词
biosensor; electrochemical impedance spectroscopy; impedance-based biosensor; LABEL-FREE DETECTION; GOLD NANOPARTICLES; SENSITIVE DETECTION; ELECTROCHEMICAL DETECTION; IMPEDANCE SPECTROSCOPY; SIGNAL AMPLIFICATION; ULTRASENSITIVE DETECTION; DISPOSABLE IMMUNOSENSOR; SALMONELLA-TYPHIMURIUM; DNA HYBRIDIZATION;
D O I
10.3109/21691401.2014.942456
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Electrochemical impedance spectroscopy (EIS) is a sensitive technique for the analysis of the interfacial properties related to biorecognition events such as reactions catalyzed by enzymes, biomolecular recognition events of specific binding proteins, lectins, receptors, nucleic acids, whole cells, antibodies or antibody-related substances, occurring at the modified surface. Many studies on impedimetric biosensors are focused on immunosensors and aptasensors. In impedimetric immunosensors, antibodies and antigens are bound each other and thus immunocomplex is formed and the electrode is coated with a blocking layer. As a result of that electron transfer resistance increases. In impedimetric aptasensors, impedance changes following the binding of target sequences, conformational changes, or DNA damages. Impedimetric biosensors allow direct detection of biomolecular recognition events without using enzyme labels. In this paper, impedimetric biosensors are reviewed and the most interesting ones are discussed.
引用
收藏
页码:248 / 262
页数:15
相关论文
共 50 条
  • [21] Impedimetric graphene-based biosensors for the detection of polybrominated diphenyl ethers
    Gutes, Albert
    Lee, Byung-Yang
    Carraro, Carlo
    Mickelson, Willi
    Lee, Seung-Wuk
    Maboudian, Roya
    NANOSCALE, 2013, 5 (13) : 6048 - 6052
  • [22] Roles of Interdigitated Electrode Geometry in Non-Faradaic Impedimetric Biosensors
    Assaifan, Abdulaziz K.
    Almansour, Rawan A.
    Alessa, Jana A.
    Alhudaithy, Soliman
    Fakhouri, Abdulaziz S.
    Alsaleh, Ahmad A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (08)
  • [23] Impedimetric immunosensors-A review
    Prodromidis, Mamas I.
    ELECTROCHIMICA ACTA, 2010, 55 (14) : 4227 - 4233
  • [24] Performance Improvement by Layout Designs of Conductive Polymer Microelectrode Based Impedimetric Biosensors
    Rosati, Giulio
    Dapra, Johannes
    Cherre, Solene
    Rozlosnik, Noemi
    ELECTROANALYSIS, 2014, 26 (06) : 1400 - 1408
  • [25] Graphene Oxide as a Novel Signal Enhancer for Cell-Based Impedimetric Biosensors
    Tra Nguyen
    Viet Duc Nguyen
    TrongBinh Tran
    Kim, Jaekwang
    Yoon, Songhun
    Min, Junhong
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2017, 17 (11) : 7991 - 7995
  • [26] Electrochemical biosensors for SARS-CoV-2 detection: Voltametric or impedimetric transduction?
    Antiochia, Riccarda
    Bioelectrochemistry, 2022, 147
  • [27] Electrochemical biosensors for SARS-CoV-2 detection: Voltametric or impedimetric transduction?
    Antiochia, Riccarda
    BIOELECTROCHEMISTRY, 2022, 147
  • [28] Impedimetric biosensors for detecting VEGF based on PEDOT carboxylic acid/ PEDOT copolymer
    Kim, Minsoo
    Iezzi, Raymond
    Martin, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [29] Effect of Applied AC Voltage on the Performance of Non-Faradaic Impedimetric Biosensors
    Alzahrani, Khalid E.
    Almansour, Meshael J.
    Qurayshan, Shahad M.
    Albrithen, Hamad
    Fakhouri, Abdulaziz S.
    Alhussaini, Khalid
    Assaifan, Abdulaziz K.
    Alodhayb, Abdullah N.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (03)
  • [30] Certain Methods of Electrode Pretreatment Create Misleading Responses in Impedimetric Aptamer Biosensors
    Ho, Lance St John
    Limson, Janice L.
    Fogel, Ronen
    ACS OMEGA, 2019, 4 (03): : 5839 - 5847