Fully automated determination of eserine N-oxide in human plasma using on-line solid-phase extraction with liquid chromatography coupled with electrospray ionization tandem mass spectrometry

被引:0
|
作者
Pruvost, A
Ragueneau, I
Ferry, A
Jaillon, P
Grognet, JM
Benech, H [1 ]
机构
[1] CEA Saclay, DRM, DSV, Serv Pharmacol & Immunol, F-91191 Gif Sur Yvette, France
[2] St Antoine Univ Hosp, Clin Pharmacol Unit, Paris, France
[3] Labs AMIDO, F-92500 Rueil Malmaison, France
来源
JOURNAL OF MASS SPECTROMETRY | 2000年 / 35卷 / 05期
关键词
eserine N-oxide; liquid chromatography/tandem mass spectrometry; automation; prospekt; pharmacokinetics;
D O I
10.1002/(SICI)1096-9888(200005)35:5<625::AID-JMS988>3.0.CO;2-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N-oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for use in pharmacokinetic studies, ENO is light-sensitive and the use of a fully on-line process increased the reliability of the assay, Plasma samples previously mixed with neostigmine bromide to prevent in vitro degradation, and tacrine as internal standard (IS), were directly injected into the SPE/LC/ESI-MS/MS system. MS software piloted the overall system. MS/MS detection of ENO and the IS was performed in the positive ion ESI mode using multiple reaction monitoring. The linear calibration curve for ENO ranged from 25 pg ml(-1) to 12.5 ng ml(-1). The limit of quantitation was 25 pg ml(-1) with 250 mu l of plasma injected. Precision, accuracy and stability tests were within the acceptable range and just one analyst is required to analyze 50 unknown samples a day five days per week, from the preparation of the samples (i.e. thawing and centrifugation) to data processing. A pilot pharmacokinetic study in three healthy volunteers treated with 4.5 mg of ENO (Geneserine3(R)) showed that the method was suitable for pharmacokinetic studies in humans. Copyright (C) 2000 John Wiley & Sons, Ltd.
引用
收藏
页码:625 / 633
页数:9
相关论文
共 50 条
  • [21] Simultaneous determination of gentisic, salicyluric and salicylic acid in human plasma using solid-phase extraction, liquid chromatography and electrospray ionization mass spectrometry
    Pirker, R
    Huck, CW
    Popp, M
    Bonn, GK
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (02): : 257 - 264
  • [22] Determination of the glucocorticoid fluticasone propionate in plasma by automated solid-phase extraction and liquid chromatography tandem mass spectrometry
    Callejas, SL
    Biddlecombe, RA
    Jones, AE
    Joyce, KB
    Pereira, AI
    Pleasance, S
    JOURNAL OF CHROMATOGRAPHY B, 1998, 718 (02): : 243 - 250
  • [23] Determination of talinolol in human plasma using automated on-line solid phase extraction combined with atmospheric pressure chemical ionization tandem mass spectrometry
    Bourgogne, E
    Grivet, C
    Hopfgartner, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (01): : 103 - 110
  • [24] Determination of pesticide residues in wine by solid-phase extraction on-line combined with liquid chromatography tandem mass spectrometry
    Perez-Mayan, L.
    Ramil, M.
    Cela, R.
    Rodriguez, I.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2021, 104
  • [25] Determination of several pesticides in water by solid-phase extraction, liquid chromatography and electrospray tandem mass spectrometry
    Rodrigues, Alexandre Mourao
    Ferreira, Vera
    Cardoso, Vitor Vale
    Ferreira, Elisabete
    Benoliel, Maria Joao
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) : 267 - 278
  • [26] Picogram per liter level determination of estrogens in natural waters and waterworks by a fully automated on-line solid-phase extraction-liquid chromatography-electrospray tandem mass spectrometry method
    Rodriguez-Mozaz, S
    de Alda, MJL
    Barceló, D
    ANALYTICAL CHEMISTRY, 2004, 76 (23) : 6998 - 7006
  • [27] Fully automated multianalyte determination of different classes of pesticides, at picogram per litre levels in water, by on-line solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry
    Kampioti, AA
    da Cunha, ACB
    de Alda, ML
    Barceló, D
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (08) : 1815 - 1825
  • [28] Determination of higenamine in human plasma and urine using liquid chromatography coupled to positive electrospray ionization tandem mass spectrometry
    Feng, Sheng
    Hu, Pei
    Jiang, Ji
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (11-12): : 763 - 768
  • [29] Automated solid-phase extraction and liquid chromatography-electrospray ionization-mass spectrometry for the determination of flunitrazepam and its metabolites in human urine and plasma samples
    Jourdil, N
    Bessard, J
    Vincent, F
    Eysseric, H
    Bessard, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (02): : 207 - 219
  • [30] Quantitative determination of the diastereoisomers of hexabromocyclododecane in human plasma using liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Tang, Caiming
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (31): : 3317 - 3322