High Performance Partial Coherent X-Ray Ptychography

被引:5
|
作者
Enfedaque, Pablo [1 ]
Chang, Huibin [1 ,2 ]
Enders, Bjoern [3 ]
Shapiro, David [4 ]
Marchesini, Stefano [1 ]
机构
[1] Lawrence Berkeley Natl Lab, Computat Res Div, Berkeley, CA 94720 USA
[2] Tianjin Normal Univ, Sch Math Sci, Tianjin, Peoples R China
[3] Lawrence Berkeley Natl Lab, Natl Energy Res Sci Comp Ctr, Berkeley, CA USA
[4] Lawrence Berkeley Natl Lab, Adv Light Source, Berkeley, CA USA
来源
基金
中国国家自然科学基金;
关键词
PHASE RETRIEVAL; RESOLUTION;
D O I
10.1007/978-3-030-22734-0_4
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
During the last century, X-ray science has enabled breakthrough discoveries in fields as diverse as medicine, material science or electronics, and recently, ptychography has risen as a reference imaging technique in the field. It provides resolutions of a billionth of a meter, macroscopic field of view, or the capability to retrieve chemical or magnetic contrast, among other features. The goal of ptychography is to reconstruct a 2D visualization of a sample from a collection of diffraction patterns generated from the interaction of a light source with the sample. Reconstruction involves solving a nonlinear optimization problem employing a large amount of measured data-typically two orders of magnitude bigger than the reconstructed sample-so high performance solutions are normally required. A common problem in ptychography is that the majority of the flux from the light sources is often discarded to define the coherence of an illumination. Gradient Decomposition of the Probe (GDP) is a novel method devised to address this issue. It provides the capability to significantly improve the quality of the image when partial coherence effects take place, at the expense of a three-fold increase of the memory requirements and computation. This downside, along with the fine-grained degree of parallelism of the operations involved in GDP, makes it an ideal target for GPU acceleration. In this paper we propose the first high performance implementation of GDP for partial coherence X-ray ptychography. The proposed solution exploits an efficient data layout and multi-gpu parallelism to achieve massive acceleration and efficient scaling. The experimental results demonstrate the enhanced reconstruction quality and performance of our solution, able process up to 4 million input samples per second on a single high-end workstation, and compare its performance with a reference HPC ptychography pipeline.
引用
收藏
页码:46 / 59
页数:14
相关论文
共 50 条
  • [21] The influence of strain on image reconstruction in Bragg coherent X-ray diffraction imaging and ptychography
    Kim, Chan
    Scholz, Markus
    Madsen, Anders
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 1159 - 1165
  • [22] X-ray imaging microscope with a partial coherent illumination
    Takeuchi, A
    Takano, H
    Uesugi, K
    Suzuki, Y
    X-RAY MICRO- AND NANO-FOCUSING: APPLICATIONS AND TECHNIQUES II, 2001, 4499 : 29 - 37
  • [23] Continuous motion scan ptychography: characterization for increased speed in coherent x-ray imaging
    Deng, Junjing
    Nashed, Youssef S. G.
    Chen, Si
    Phillips, Nicholas W.
    Peterka, Tom
    Ross, Rob
    Vogt, Stefan
    Jacobsen, Chris
    Vine, David J.
    OPTICS EXPRESS, 2015, 23 (05): : 5438 - 5451
  • [24] Hard X-ray ptychography for optics characterization using a partially coherent synchrotron source
    Moxham, Thomas E. J.
    Parsons, Aaron
    Zhou, Tunhe
    Alianelli, Lucia
    Wang, Hongchang
    Laundy, David
    Dhamgaye, Vishal
    Fox, Oliver J. L.
    Sawhney, Kawal
    Korsunsky, Alexander M.
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 1688 - 1695
  • [25] On-the-fly scans for X-ray ptychography
    Pelz, Philipp M.
    Guizar-Sicairos, Manuel
    Thibault, Pierre
    Johnson, Ian
    Holler, Mirko
    Menzel, Andreas
    APPLIED PHYSICS LETTERS, 2014, 105 (25)
  • [26] Chemical Contrast in Soft X-Ray Ptychography
    Beckers, Mike
    Senkbeil, Tobias
    Gorniak, Thomas
    Reese, Michael
    Giewekemeyer, Klaus
    Gleber, Sophie-Charlotte
    Salditt, Tim
    Rosenhahn, Axel
    PHYSICAL REVIEW LETTERS, 2011, 107 (20)
  • [27] Multiscale X-ray imaging using ptychography
    Sala, Simone
    Kuppili, Venkata S. C.
    Chalkidis, Stefanos
    Batey, Darren J.
    Shi, Xiaowen
    Rau, Christoph
    Thibault, Pierre
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1214 - 1221
  • [28] Soft X-ray ptychography method at SSRF
    Chun-Peng Wang
    Zi-Jian Xu
    Hai-Gang Liu
    Xulei Tao
    Ren-Zhong Tai
    Nuclear Science and Techniques, 2017, 28
  • [29] Precession x-ray ptychography with multislice approach
    Shimomura, Kei
    Suzuki, Akihiro
    Hirose, Makoto
    Takahashi, Yukio
    PHYSICAL REVIEW B, 2015, 91 (21):
  • [30] High-performance 4-nm-resolution X-ray tomography using burst ptychography
    Aidukas, Tomas
    Phillips, Nicholas W.
    Diaz, Ana
    Poghosyan, Emiliya
    Muller, Elisabeth
    Levi, A. F. J.
    Aeppli, Gabriel
    Guizar-Sicairos, Manuel
    Holler, Mirko
    NATURE, 2024, 632 (8023) : 81 - +