Hurricane vulnerability of multi-story residential buildings in Florida

被引:0
|
作者
Pita, G. L. [1 ]
Pinelli, J. -P. [1 ]
Subramanian, C. S. [1 ]
Gurley, K. [1 ]
Hamid, S.
机构
[1] Florida Inst Technol, Melbourne, FL 32901 USA
关键词
PROJECTION; MODEL;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In recent years, a multi-disciplinary team has developed the Florida Public Hurricane Loss Model. The model combines state-of-the-art technology in the fields of meteorology, engineering, actuarial science, and computer science to predict hurricane-induced losses for single-family homes. The model is now being extended to cover multi-family buildings ranging from a few stories to the high rise condominiums typically found lining the beaches of South Florida. These are engineered structures with a large variety of structural types, shapes, and heights. To address the challenge of predicting hurricane losses for these structures, the meteorologists are developing a new 3D model of the wind field, and the engineers are working on a new vulnerability model to incorporate the effects of height and associated air jets on the buildings' vulnerabilities. The first step in this process is to carry out a comprehensive survey of the multi-family buildings stock in Florida, to identify the most prevalent characteristics of the structures, their relationship to hurricane risk, and their geographic distribution. This paper describes the outcome of the exposure study, with an analysis of the hurricane risk attached to multi-family, multi-story buildings and a comparison to single-family homes. The authors conclude with a description of the strategy developed to quantify the potential hurricane losses associated with a portfolio of multi-unit structures including building and contents losses, and additional living expenses.
引用
收藏
页码:2453 / +
页数:2
相关论文
共 50 条
  • [21] Effects of Story-by-Story Post-Tensioning on Multi-Story Buildings
    Guo, Guohui
    Joseph, Leonard M.
    Darwin, David
    ACI STRUCTURAL JOURNAL, 2013, 110 (04) : 649 - 657
  • [22] Effects of story-by-story post-tensioning on multi-story buildings
    1600, American Concrete Institute (110):
  • [23] Estimation of earthquake induced story hysteretic energy of multi-Story buildings
    Wang, Feng
    Zhang, Ning
    Huang, Zhiyu
    EARTHQUAKES AND STRUCTURES, 2016, 11 (01) : 165 - 178
  • [24] Unsymmetricity effects on seismic performance of multi-story buildings
    Pandian, Antony Vimal Paul
    Arunachalam, Krishna Prakash
    Bahrami, Alireza
    Romero, Lenin Miguel Bendezu
    Avudaiappan, Siva
    Awoyera, Paul O.
    DISCOVER APPLIED SCIENCES, 2024, 6 (09)
  • [26] Distribution of heating costs in multi-story apartment buildings
    Rose, Jorgen
    Kragh, Jesper
    11TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB2017), 2017, 132 : 1012 - 1017
  • [27] Seismic performance of multi-story modular box buildings
    Feng, Ruoqiang
    Shen, Liu
    Yun, Qiu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 168 (168)
  • [28] New directions in seismic monitoring of multi-story buildings
    Safak, E
    STRUCTURAL HEALT H MONITORING: CURRENT STATUS AND PERSPECTIVES, 1997, : 418 - 429
  • [29] Modular standardization criteria applied in multi-story residential buildings in Cross-Laminated Timber (CLT)
    Vargas-Mosqueda, M.
    Saelzer-Fuica, G.
    Pereira, M. E.
    Navarro-Ortiz, A. M.
    Garcia-Alvarado, R.
    REVISTA INGENIERIA DE CONSTRUCCION, 2023, 38 (01): : 186 - 203
  • [30] Hurricane vulnerability model for mid/high-rise residential buildings
    Pita, Gonzalo L.
    Pinelli, Jean-Paul
    Gurley, Kurt
    Weekes, Johann
    Cocke, Steve
    Hamid, Shahid
    WIND AND STRUCTURES, 2016, 23 (05) : 449 - 464