A new portable chest drainage device

被引:14
|
作者
Lodi, R [1 ]
Stefani, A [1 ]
机构
[1] Univ Modena, Dept Cardiothorac Surg, I-41100 Modena, Italy
来源
ANNALS OF THORACIC SURGERY | 2000年 / 69卷 / 04期
关键词
D O I
10.1016/S0003-4975(99)01567-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. persistent air leak is a frequent complication in lung operation. The Heimlich valve is the standard system for venting the pleural cavity. The device achieves good results and is well tolerated, but the main problem is when air leak is associated with fluid leakage. Methods. In order to improve the outpatient management of persistent air and fluid drainage after resectional procedures, we developed an original device. It is a portable system provided with a one-way valve connected to the chest tube for drainage of air and fluid, a reservoir for collecting fluid, and a one-way exhaust valve to evacuate air from the bag. Results. We analyze the advantages of our device versus the Heimlich valve in the first series of 18 selected patients. Our system is drier and cleaner, easier to manage, and ambulatory visits are seldom needed. There is also a cost savings. Conclusions. Our device enhances ambulation, independence, and the quality of life of the patients, and decreases the need for hospital and outpatient care. (C) 2000 by The Society of Thoracic Surgeons.
引用
收藏
页码:998 / 1001
页数:4
相关论文
共 50 条
  • [21] Ambulatory treatment of persistent air leaks using a portable chest drainage system: Preliminary results
    Martinez Somolinos, Sandra
    Marmol Cazas, Edwin Emilio
    Sebastian Quetglas, Fernando
    Rubio Garay, Matilde Magdalena
    Baldo Padro, Xavier
    Penagos Tafurt, Juan Carlos
    CIRUGIA ESPANOLA, 2010, 88 (06): : 398 - 403
  • [22] PORTABLE CHEST RADIOGRAPHY
    ALTER, AJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 134 (01) : 203 - 203
  • [23] Development of FORGE, a new glaucoma drainage device
    Orge, Faruk H.
    Salem, Zeina
    Toris, Carol B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [24] Performance Validation of a new portable ophthalmic ultrasound device
    Venkataraju, Kannan Umadevi
    Belenje, Akash
    Das, Taraprasad
    Hansraj, Saarang
    Kannan, Kiruthika
    Pandya, Dhanush
    Kondusamy, Ravichandran
    Pappuru, Rajeev Reddy
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [25] The history of chest drainage
    Guijarro, R
    Cantó, A
    ARCHIVOS DE BRONCONEUMOLOGIA, 2002, 38 (10): : 489 - 491
  • [26] PROBLEMS WITH CHEST DRAINAGE
    EASTWOOD, N
    ANAESTHESIA, 1994, 49 (01) : 89 - 89
  • [27] CHEST DRAINAGE TUBES
    SYMBAS, PN
    SURGICAL CLINICS OF NORTH AMERICA, 1989, 69 (01) : 41 - 46
  • [28] A NEW, PORTABLE ELECTRONIC DEVICE FOR THE EARLY DIAGNOSIS OF MASTITIS
    FACSAR, I
    BAN, I
    MAGYAR ALLATORVOSOK LAPJA, 1992, 47 (08) : 418 - 422
  • [29] Monitoring the effects of heparin: evaluation of a new portable device
    Cavanagh, SP
    Haine, L
    Ammori, B
    Tate, G
    Braithwaite, P
    Gough, MJ
    Homer-Vanniasinkam, S
    CARDIOVASCULAR SURGERY, 1998, 6 (05): : 496 - 499
  • [30] The Chest Tube Drainage
    Klopp, Michael
    Hoffmann, Hans
    Dienemann, Hendrik
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2015, 140 (05) : 338 - 342