IVBT-documented platelet function correlates with flow cytometric data

被引:2
|
作者
Hoffmann, J [1 ]
Bonacker, G [1 ]
Kretschmer, V [1 ]
Schulzki, T [1 ]
Heimanns, J [1 ]
机构
[1] UNIV KLINIKUM MARBURG, ABT TRANSFUS MED & GERINNUNGSPHYSIOL, DEPT TRANSFUS MED & HAEMOSTASEOL, D-35033 MARBURG, GERMANY
来源
TRANSFUSION SCIENCE | 1996年 / 17卷 / 04期
关键词
D O I
10.1016/S0955-3886(96)90091-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Thrombocytopenic patients with identical platelet counts often show different bleeding tendencies owing to significant differences in the platelet function. This could be demonstrated by the in vitro bleeding test (IVBT). Using flow cytometry, we tried to find characteristics of platelet antigen expression in order to explain these differences in function. Thirty patients with bone marrow hypoplasia receiving 65 platelet transfusions (mainly from a cell separator) were observed for 3 to 29 days. Size, granulation and fluorescence of platelet-rich plasma (n = 522 samples) were evaluated using monoclonal antibodies against CP IIIb (collagen receptor), GP IIb/IIIa (fibrinogen receptor) and GP Ib (thrombin receptor). We defined separate gates for each antibody using the results from 50 normals and by laying an orthograde cross over the gate to divide the gate into four equal quadrants. The platelet populations were divided into four different groups according to the occlusion time (OT) of the IVBT and the Simplate(R) time (ST). The thrombocytes with the most impaired function (OT greater than or equal to 485 s/ST > 30 min) had significantly less platelet fluorescence when marked with antibodies against GP IIIb and GP Ib than those with short OT and ST (OT < 100 s/ST < 15 min). Similar results were obtained when evaluating the data relative to the bone marrow status: patients with < WBC/mu l showed significantly platelet fluorescence when marked with anti-GP IIIb and anti-GP Ib than thrombocytopenic patients, who had a spontaneous platelet rise beyond 30,000 platelets/mu l a few days later. One day after platelet transfusion, significantly more, platelets with high GP IIIb and Ib expression could be found. We were also able to document better transfusion efficacy of platelet concentrates with high GP IIIb and Ib expression. Finally, patients with high bleeding scores showed less GP Ib expression on the platelets than patients with low bleeding scores. In summary, the IVBT-documented platelet: function clearly corresponded to an increased expression of the collagen receptor and the thrombin receptor of platelets. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:553 / 558
页数:6
相关论文
共 50 条
  • [21] Standardization and reference ranges for whole blood platelet function measurements using a flow cytometric platelet activation test
    Huskens, Dana
    Sang, Yaqiu
    Konings, Joke
    van der Vorm, Lisa
    de laat, Bas
    Kelchtermans, Hilde
    Roest, Mark
    PLOS ONE, 2018, 13 (02):
  • [22] EASY SCREENING OF THE PLATELET-FUNCTION USING THE INVITRO-BLEEDING-TEST (IVBT)
    DIETRICH, G
    KRETSCHMER, V
    THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 1330 - 1330
  • [23] FLOW CYTOMETRIC ASSESSMENT OF PLATELET-FUNCTION IN PATIENTS WITH PERIPHERAL ARTERIAL OCCLUSIVE DISEASE
    GALT, SW
    MCDANIEL, MD
    AULT, KA
    MITCHELL, J
    CRONENWETT, JL
    JOURNAL OF VASCULAR SURGERY, 1991, 14 (06) : 747 - 756
  • [24] EVALUATION OF A FLOW CYTOMETRIC PLATELET COUNT METHOD
    Ben Naoum, M. N.
    Lazreg, H.
    Adda, A.
    Hamadi, M.
    HAEMATOLOGICA, 2015, 100 : 772 - 772
  • [25] FLOW-CYTOMETRIC DETECTION OF PLATELET ANTIBODIES
    LAZARCHICK, J
    HALL, S
    GENCO, PV
    PONZIO, AD
    BURDASH, NM
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1985, 15 (04): : 336 - 336
  • [26] DETECTION OF PLATELET ANTIBODIES BY FLOW CYTOMETRIC ANALYSIS
    LAZARCHICK, J
    GENCO, PV
    HALL, SA
    PONZIO, AD
    BURDASH, NM
    DIAGNOSTIC IMMUNOLOGY, 1984, 2 (04): : 238 - 241
  • [27] FLOW CYTOMETRIC MEASUREMENT OF THE PLATELET SHAPE CHANGE
    RUF, A
    PATSCHEKE, H
    THROMBOSIS AND HAEMOSTASIS, 1993, 69 (06) : 702 - 702
  • [28] Platelet cold agglutinins: a flow cytometric analysis
    Schimmer, A
    Mody, M
    Sager, M
    Garvey, MB
    Hogarth, M
    Freedman, J
    TRANSFUSION SCIENCE, 1998, 19 (03): : 217 - 224
  • [29] Flow cytometric detection of intracellular platelet antigens
    Sedlmayr, P
    Grosshaupt, B
    Muntean, W
    CYTOMETRY, 1996, 23 (04): : 284 - 289
  • [30] Analysis of flow cytometric data
    Quinn, J
    Loo, LH
    Capocasale, R
    Bugelski, P
    Kam, M
    Hrebien, L
    PROCEEDINGS OF THE IEEE 29TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2003, : 244 - 245