A New Type of Large-Surface Bismuth Film Electrode on a Silver Solid Amalgam Substrate and its Application for the Voltammetric Determination of 5-Nitrobenzimidazole

被引:0
|
作者
Deylova, Dana [1 ]
Vyskocil, Vlastimil [1 ]
Economou, Anastasios [2 ]
Mansfeldova, Vera [3 ]
Barek, Jiri [1 ]
机构
[1] Charles Univ Prague, Fac Sci, Univ Res Ctr UNCE Supramol Chem, Dept Analyt Chem,UNESCO Lab Environm Electrochem, Prague 12843 2, Czech Republic
[2] Univ Athens, Dept Chem, Analyt Chem Lab, Athens 15771, Greece
[3] J Heyrovsky Inst Phys Chem, AS CR, Vvi, Prague 18223 8, Czech Republic
来源
关键词
Large-surface bismuth film electrode; Silver solid amalgam substrate; Atomic force microscopy; 5-Nitrobenzimidazole; Direct current voltammetry; Differential pulse voltammetry; Tap and mineral water; ADSORPTIVE STRIPPING VOLTAMMETRY; 4-NITROPHENOL; NITROPHENOLS; DERIVATIVES; NITRO;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel type of large-surface bismuth film electrode prepared by electrochemical deposition of bismuth on a silver solid amalgam electrode (LSBiF-AgSAE) was developed. A silver solid amalgam substrate with a diameter of 2.64 mm was used to achieve larger surface of this electrode resulting in higher sensitivity in the voltammetric analysis. The larger electrode surface required longer time (i.e., 1800 s) for the electrochemical deposition of the bismuth film. The electrode surface of thus prepared electrode was characterized by atomic force microscopy (AFM) which confirmed that the bismuth film was not grown uniformly over the supporting surface, but created three-dimensional higher formations which cover only a fraction of the surface. To verify the practical application of the new LSBiF-AgSAE, the voltammetric behavior of genotoxic 5-nitrobenzimidazole (5-NBIA) was investigated using direct current voltammetry (DCV) and differential pulse voltammetry (DPV), and optimum conditions were found for its determination in the concentration range from 0.2 to 1000 mu mol L-1 in the Britton-Robinson buffer solution (pH 7.0), with the limits of quantification (L(Q)s) 0.37 mu mol L-1 (DCV) and 0.07 mu mol L-1 (DPV). An attempt to increase the sensitivity using adsorptive stripping DCV or DPV at the BiF-AgSAE was not successful. The practical applicability of the newly developed electrode was verified on direct determination of 5-NBIA in tap and mineral water model samples, with L(Q)s approximate to 0.1 mu mol L-1 mol L-1.
引用
收藏
页码:4653 / 4664
页数:12
相关论文
共 24 条
  • [1] Voltammetric Determination of 5-Nitrobenzimidazole at a Carbon Film Electrode Deposited on a Silver Solid Amalgam Electrode
    Deylova, Dana
    Barek, Jiri
    XXXII. MODERNI ELEKTROCHEMICKE METODY, 2012, : 27 - 31
  • [2] Bismuth film electrode at a silver solid amalgam substrate as a new tool for voltammetric determination of electrochemically reducible organic compounds
    Deylova, Dana
    Vyskocil, Vlastimil
    Barek, Jiri
    Economou, Anastasios
    TALANTA, 2012, 102 : 68 - 74
  • [3] Voltammetric Determination of 4-Nitrophenol and 5-Nitrobenzimidazole Using Different Types of Silver Solid Amalgam Electrodes - A Comparative Study
    Deylova, Dana
    Yosypchuk, Bogdan
    Vyskocil, Vlastimil
    Barek, Jiri
    ELECTROANALYSIS, 2011, 23 (07) : 1548 - 1555
  • [4] Voltammetric determination of 2-amino-6-nitrobenzothiazole and 5-nitrobenzimidazole using a silver solid amalgam electrode modified by a microcrystalline natural graphite-polystyrene composite film
    Deylova, Dana
    Vyskocil, Vlastimil
    Barek, Jiri
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 717 : 237 - 242
  • [5] Voltammetric Determination of Chlorpromazine Hydrochloride Using a Large-Surface Carbon Film Electrode
    Nemcova, Vendula
    Vyskocil, Vlastimil
    Barek, Jiri
    XXXVII MODERNI ELEKTROCHEMICKE METODY, 2017, : 155 - 157
  • [6] VOLTAMMETRIC DETERMINATION OF 4-NITROPHENOL ON LARGE-SURFACE CARBON FILM ELECTRODE
    Smejkalova, Hana
    Vyskocil, Vlastimil
    CHEMICKE LISTY, 2013, 107 : S265 - S269
  • [7] A Large-Surface Carbon Film Electrode Used for Voltammetric Determination of Imipramine Hydrochloride
    Nemcova, Vendula
    Vyskocil, Vlastimil
    Barek, Jiri
    PROCEEDINGS OF THE 13TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2017, : 111 - 115
  • [8] Electrochemical Study of Moroxydine and its Voltammetric Determination with a Silver Amalgam Film Electrode
    Skrzypek, S.
    ELECTROANALYSIS, 2011, 23 (12) : 2781 - 2788
  • [9] Large-Surface Carbon Film Electrode - A Simple Sensor for Voltammetric Determination of Electrochemically Reducible Organic Compounds
    Smejkalova, Hana
    Vyskocil, Vlastimil
    CHEMICKE LISTY, 2014, 108 (03): : 264 - 270
  • [10] Reduction behavior of insecticide azoxystrobin and its voltammetric determination using silver solid amalgam electrode
    Renáta Šelešovská
    Marie Herynková
    Jana Skopalová
    Pavlína Kelíšková-Martinková
    Lenka Janíková
    Jaromíra Chýlková
    Monatshefte für Chemie - Chemical Monthly, 2019, 150 : 419 - 428