Measurements and analysis of temperature rise at electrodes of a vacuum interrupter for high current applications

被引:0
|
作者
Yamano, Y [1 ]
Kobayashi, S [1 ]
Matsukawa, M [1 ]
机构
[1] Saitama Univ, Dept Elect & Elect Syst, Saitama 3388570, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High current switching technology is required for protection of large superconducting coil in the field of nuclear fusion research. Temperature rise of the contacts and temperature distribution along the current feeding electrodes were measured. The contact diameter was 25 mm, and the tested material was Cu-Cr with different mixing ratios. Effect of a heat pipe was investigated as well. Measurements revealed that for the heat pipe installed case the temperature at the contact reached about 130 degreesC after the current conducting test of 2000 A for 120 min, while for non heat pipe case the temperature reached 185 degreesC.
引用
收藏
页码:419 / 422
页数:4
相关论文
共 50 条
  • [41] High temperature pH measurements using novel pH electrodes
    Electric Power Research Institute, (Report) EPRI TR, 1996, (105974s):
  • [42] Investigation of CuCr Electrodes Microstructure After Effect of a High Current Vacuum Arc
    Schneider, Anton V.
    Yakolev, Evgeniy V.
    Popov, Sergey A.
    Batrakov, Alexander V.
    PROCEEDINGS OF THE 2018 28TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2018), VOL 1, 2018, : 235 - 238
  • [43] POSSIBILITY OF HIGH-CURRENT INTERRUPTION OF VACUUM INTERRUPTER WITH LOW SURGE CONTACT MATERIAL - IMPROVED AG-WC
    KANEKO, E
    YOKOKURA, K
    HOMMA, M
    SATOH, Y
    OKAWA, M
    OKUTOMI, I
    OHSHIMA, I
    IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (02) : 797 - 803
  • [44] Measurements and modeling in the current zero region of vacuum circuit breakers for high current interruption
    Kaumanns, J
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1997, 25 (04) : 632 - 636
  • [45] Research on temperature rise of high current switchgear in distribution system
    Wang, Xiaorui
    Cai, Suxiong
    Peng, Zhaowei
    Yu, Zhanqing
    Gao, Shisen
    Huang, Zerong
    Guan, Yonggang
    Xia, Haotian
    Zeng, Rong
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2931 - 2934
  • [46] Measurements and modeling in the current zero region of vacuum circuit breakers for high current interruption
    Hochspannungstechnik der RWTH Aachen, Aachen, Germany
    IEEE Trans Plasma Sci, 4 (632-636):
  • [47] Measurements and modelling in the current zero region of vacuum circuit breakers for high current interruption
    Kaumanns, J
    ISDEIV - XVIITH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, PROCEEDINGS, VOLS I AND II, 1996, : 276 - 280
  • [48] The Threshold Welding Current for Closed Vacuum Interrupter Contacts with 'n' Regions of Contact for Short Duration, High Fault Currents
    Slade, Paul G.
    Taylor, Erik D.
    Lawall, Andreas
    28TH INTERNATIONAL CONFERENCE ON ELECTRIC CONTACTS (ICEC2016), 2016, : 51 - 56
  • [49] The Applications of Current Comparators in the Measurements on High Voltage Insulation
    Fei, Yi-jun
    Dong, Xu
    Chen, Jie
    Zheng, Huan
    Cao, Jing-ying
    Li, Zhong-hua
    2015 INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING AND ELECTRICAL SYSTEMS (ICMES 2015), 2016, 40
  • [50] A VACUUM SEAL BETWEEN METALS AND CERAMICS FOR HIGH TEMPERATURE APPLICATIONS
    SODERSTROM, HW
    MCPHEE, KH
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1950, 38 (02): : 210 - 210