Indirect spray evaporative thermal management for semiconductor burn-in

被引:0
|
作者
Benjamin, Michael A. [1 ]
Odar, Andrew M. [1 ]
Steinthorsson, Erlendur [1 ]
Cotten, Charles B. [1 ]
机构
[1] Parker Hannifin Corp, Mentor, OH USA
来源
Advances in Electronic Packaging 2005, Pts A-C | 2005年
关键词
liquid cooling; spray cooling; spray evaporative cooling; multipoint spray cooling; semiconductor test;
D O I
10.1115/IPACK2005-73189
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Semiconductor bum-in testing is one of several quality assurance tests conducted during High Volume Manufacturing (HVM) of semiconductor logic devices. The goal of bum-in is to induce "infant mortality" component failures. To accelerate infant mortality defects, semiconductor devices are subjected to stressing techniques that induce heat levels, typically, 100%-300% greater than end use environment heat loads. For this work, an indirect spray cooling method was developed and experimentally evaluated. In the indirect method, sprays are sealed within a spraycap (evaporator) that is thermally connected with the heated surface by way of a thermal interface material. The test fluid is the perfluorocarbon HFE-7000 that has a boiling point of 34 degrees C at 1 atm. pressure. Experiments were run at a spraycap nominal pressure of I atm. with about 16 degrees C of liquid subcooling at the inlet. Tests were performed on a lidded Thermal Test Vehicle (TTV) device (1.2 cm(2) die size) to measure the thermal solution maximum power, dynamic control, repeatability, and the effect of applied force. Time varying test patterns (thermal loads) are simulated by changing TTV power in 20 W steps up to 200 W. The pertinent output measurements for performance evaluation are TTV power and junction temperatures (Tj), thermocouple measurements in the heat path, coolant flow rate, and applied force to the TTV. From these measurements, resultant parameters of thermal resistance and heat transfer coefficients are calculated. Maximum TTV power maintaining Tj at or below 105 degrees C was shown to approach 240 W. Thermal controllability of the system was demonstrated for a Tj of 105 degrees C over the TTV power range of 30 W to 200 W. Performance was extremely stable and very repeatable even when the spraycap exit quality was 100%. The thermal solution demonstrated good repeatability during a limited cycle test. Contact force of approximately 10 lb(f) (45 N) was found to minimize the thermal resistance of the solution, and no significant improvement is realized beyond that force level.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 50 条
  • [41] Adaptive Management Techniques for Optimized Burn-in of Safety-Critical SoC
    Appello, Davide
    Bernardi, Paolo
    Bugeja, Conrad
    Cantoro, Riccardo
    Pollaccia, Giorgio
    Restifo, Marco
    Venini, Federico
    JOURNAL OF ELECTRONIC TESTING-THEORY AND APPLICATIONS, 2018, 34 (01): : 43 - 52
  • [42] A DYNAMIC BIAS SYSTEM FOR BURN-IN OR THERMAL ENDURANCE TREATMENTS OF 8085A MICROPROCESSORS
    SHAW, RN
    MICROELECTRONICS AND RELIABILITY, 1982, 22 (01): : 117 - 130
  • [43] Thermal analysis on the impact of spray charactristics on evaporative cooling process
    Amoli, Behzad Siavash
    Ajarostaghi, Seyed Soheil Mousavi
    Sedighi, Kurosh
    Delavar, Mojtaba Aghajani
    JOURNAL OF THERMAL ENGINEERING, 2022, 8 (01): : 90 - 102
  • [44] A wafer-level burn-in technology using the contactor controlled thermal expansion
    Nakata, Y
    Miyanaga, I
    Oki, S
    Fujimoto, H
    1997 INTERNATIONAL CONFERENCE ON MULTICHIP MODULES - PROCEEDINGS, 1997, : 259 - 264
  • [45] Two-level differential burn-in policy for spatially heterogeneous defect units in semiconductor manufacturing
    Chen, Yuan
    Yuan, Tao
    Bae, Suk Joo
    Kuo, Yue
    COMPUTERS & INDUSTRIAL ENGINEERING, 2021, 162
  • [46] The Possibility of Intermittent Water Spray Implementation in a Non-Porous Indirect Evaporative Cooler
    Stefaniak, Lukasz
    Walaszczyk, Juliusz
    Karpuk, Michal
    Rajski, Krzysztof
    Danielewicz, Jan
    ENERGIES, 2025, 18 (04)
  • [47] Spray cooling thermal management of a semiconductor chip undergoing probing, diagnostics, and failure analysis
    Ansari, S
    Cader, T
    Frank, J
    Cotton, D
    Wong, T
    Pakdaman, N
    ADVANCES IN ELECTRONIC PACKAGING 2003, VOL 1, 2003, : 73 - 80
  • [48] Spray parameter analysis and performance optimization of indirect evaporative cooler considering surface wettability
    Ma, Xiaochen
    Shi, Wenchao
    Yang, Hongxing
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [49] Thermal performance analysis of a mixed-flow indirect evaporative cooler
    Deepak, C.
    Naik, Rudra
    Godi, Sangamesh C.
    Mangrulkar, Chidanand K.
    Prashanth, H. K.
    APPLIED THERMAL ENGINEERING, 2022, 217
  • [50] Burn-in test and thermal performance evaluation of Silicon Photomultipliers for the JUNO-TAO experiment
    Chen, X.
    Cao, G. F.
    Qu, M. H.
    Wang, H. W.
    Anfimov, N.
    Rybnikov, A.
    Xu, J. Y.
    Su, A. Q.
    Chen, Z. L.
    Cao, J.
    Li, Y. C.
    Qi, M.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (07):