In Situ Visualization of Tears on Contact Lens Using Ultra High Resolution Optical Coherence Tomography

被引:52
|
作者
Wang, Jianhua [1 ]
Jiao, Shuliang
Ruggeri, Marco
Abou Shousha, Mohammed
Chen, Qi [2 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
来源
关键词
Tear dynamics; Optical coherence tomography; Contact lens; VIVO;
D O I
10.1097/ICL.0b013e31819579f2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To demonstrate. the capability of directly visualizing the tear film on contact lenses using optical coherence tomography (OCT). Methods: Six eyes of three healthy subjects wearing PureVision and ACUVUE Advance soft and Boston RGP hard contact lenses were imaged with a custom built, high speed, ultra-high resolution spectral domain optical coherence tomograph. Refresh Liquigel was used to demonstrate the effect of artificial tears on the tear film. Results: Ultra high resolution images of the pre- and post-lens films were directly visualized when each lens was inserted onto the eye. After the instillation of artificial tears during lens wear, the tear film was thicker. The post-lens tear film underneath the lens edge was clearly shown. Interactions between the lens edges and the ocular surface were obtained for each of the lens types and base curves. With a contrast enhancement agent, tear menisci on the contact lenses around the upper and lower eyelids were highlighted. With hard contact lenses, the tear film was visualized clearly and changed after a blink when the lens was pulled up by the lid. Conclusions: Ultra-high resolution OCT is a potentially promising technique for imaging tears around contact lenses. This successful demonstration of in situ post-lens tear film imaging suggests that OCT could open a new era in studying tear dynamics during contact lens wear. The novel method may lead to new ways of evaluating contact lens fitting.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 50 条
  • [31] In vivo corneal high-speed, ultra-high-resolution optical coherence tomography
    Christopoulos, Viki
    Kagemann, Larry
    Wollstein, Gadi
    Ishikawa, Hi. Roshi
    Gabriele, Michelle L.
    Wojtkowski, Maciej
    Srinivasan, Vivek
    Fujimoto, James G.
    Duker, Jay S.
    Dhaliwal, Deepinder K.
    Schuman, Joel S.
    ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (08) : 1027 - 1035
  • [32] Three-dimensional imaging of eye surface pathologies and contact lens fit with high resolution Spectral Optical Coherence Tomography
    Woitkowski, M.
    Kaluzny, B.
    Szkulmowska, A.
    Bajraszewski, T.
    Szkulmowski, M.
    Targowski, P.
    Kowalczyk, A.
    OPHTHALMIC TECHNOLOGIES XVII, 2007, 6426
  • [33] Micrometer-Scale Contact Lens Movements Imaged by Ultrahigh-resolution Optical Coherence Tomography
    Cui, Lele
    Shen, Meixiao
    Wang, Michael R.
    Wang, Jianhua
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (02) : 275 - 283
  • [34] Ultra-high resolution optical coherence tomography for material characterization and quality control
    Wiesauer, K
    Pircher, M
    Götzinger, E
    Engelke, R
    Ahrens, G
    Grützner, G
    Hitzenberger, CK
    Stifter, D
    COMMERCIAL AND BIOMEDICAL APPLICATIONS OF ULTRAFAST LASERS V, 2005, 5714 : 108 - 115
  • [35] Simultaneous dual-band ultra-high resolution optical coherence tomography
    Spoeler, Felix
    Kray, Stefan
    Grychtol, Patrik
    Hermes, Barbara
    Bornemann, Joerg
    Foerst, Michael
    Kurz, Heinrich
    OPTICS EXPRESS, 2007, 15 (17) : 10832 - 10841
  • [36] Ultra-High Resolution Spectral Domain Optical Coherence Tomography of Traumatic Maculopathy
    Seider, Michael
    Lujan, Brandon J.
    Gregori, Giovanni
    Jiao, Shuliang
    Murray, Timothy G.
    Puliafito, Carmen A.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (05) : 516 - 521
  • [37] Characterization of Soft Contact Lens Edge Fitting during Daily Wear Using Ultrahigh-Resolution Optical Coherence Tomography
    Cui, Lele
    Chen, Sisi
    Zhou, Weihe
    Sheng, Kaixuan
    Zhang, Lei
    Shen, Meixiao
    Li, Ming
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [38] Diagnosis and Management of Conjunctival and Corneal Intraepithelial Neoplasia Using Ultra High-Resolution Optical Coherence Tomography
    Abou Shousha, Mohamed
    Karp, Carol L.
    Perez, Victor L.
    Hoffmann, Rodrigo
    Ventura, Roberta
    Chang, Victoria
    Dubovy, Sander R.
    Wang, Jianhua
    OPHTHALMOLOGY, 2011, 118 (08) : 1531 - 1537
  • [39] Differentiating Generic versus Branded Pharmaceutical Tablets Using Ultra-High-Resolution Optical Coherence Tomography
    Zhang, Zijian
    Williams, Bryan
    Zheng, Yalin
    Lin, Hungyen
    Shen, Yaochun
    COATINGS, 2019, 9 (05):
  • [40] Optical coherence tomography: High resolution imaging using echoes of light
    Fujimoto, James G.
    Drexler, Wolfgang
    Morgner, Uwe
    Kärtner, Franz
    Ippen, Erich
    Optics and Photonics News, 2000, 11 (01): : 23 - 31