In Situ Visualization of Tears on Contact Lens Using Ultra High Resolution Optical Coherence Tomography

被引:52
|
作者
Wang, Jianhua [1 ]
Jiao, Shuliang
Ruggeri, Marco
Abou Shousha, Mohammed
Chen, Qi [2 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
来源
关键词
Tear dynamics; Optical coherence tomography; Contact lens; VIVO;
D O I
10.1097/ICL.0b013e31819579f2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To demonstrate. the capability of directly visualizing the tear film on contact lenses using optical coherence tomography (OCT). Methods: Six eyes of three healthy subjects wearing PureVision and ACUVUE Advance soft and Boston RGP hard contact lenses were imaged with a custom built, high speed, ultra-high resolution spectral domain optical coherence tomograph. Refresh Liquigel was used to demonstrate the effect of artificial tears on the tear film. Results: Ultra high resolution images of the pre- and post-lens films were directly visualized when each lens was inserted onto the eye. After the instillation of artificial tears during lens wear, the tear film was thicker. The post-lens tear film underneath the lens edge was clearly shown. Interactions between the lens edges and the ocular surface were obtained for each of the lens types and base curves. With a contrast enhancement agent, tear menisci on the contact lenses around the upper and lower eyelids were highlighted. With hard contact lenses, the tear film was visualized clearly and changed after a blink when the lens was pulled up by the lid. Conclusions: Ultra-high resolution OCT is a potentially promising technique for imaging tears around contact lenses. This successful demonstration of in situ post-lens tear film imaging suggests that OCT could open a new era in studying tear dynamics during contact lens wear. The novel method may lead to new ways of evaluating contact lens fitting.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 50 条
  • [1] In Situ Visualization of Tears on Contact Lens Using Ultra High Resolution Optical Coherence Tomography (vol 35, pg 44, 2009)
    Abou Shousha, Mohamed
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (03): : 162 - 162
  • [2] Direct visualization of tear film on soft contact lens using ultra-high resolution spectral domain optical coherence tomography
    Wang, Jianhua
    Jiao, Shuliang
    Ruggeri, Marco
    Wehbe, Hassan
    OPHTHALMIC TECHNOLOGIES XVIII, 2008, 6844
  • [3] "In Situ" Corneal and Contact Lens Thickness Changes with High-Resolution Optical Coherence Tomography
    Gonzalez-Meijome, Jose M.
    Cervino, Alejandro
    Peixoto-de-Matos, Sofia C.
    Madrid-Costa, David
    Jorge, Jorge
    Ferrer-Blasco, Teresa
    CORNEA, 2012, 31 (06) : 633 - 638
  • [4] High-Resolution Spectral Domain Optical Coherence Tomography Technology for the Visualization of Contact Lens to Cornea Relationships
    Gonzalez-Meijome, Jose M.
    Cervino, Alejandro
    Carracedo, Gonzalo
    Queiros, Antonio
    Garcia-Lazaro, Santiago
    Ferrer-Blasco, Teresa
    CORNEA, 2010, 29 (12) : 1359 - 1367
  • [5] Characterization of Soft Contact Lens Edge Fitting Using Ultra-High Resolution and Ultra-Long Scan Depth Optical Coherence Tomography
    Shen, Meixiao
    Cui, Lele
    Riley, Colleen
    Wang, Michael R.
    Wang, Jianhua
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) : 4091 - 4097
  • [6] Automated contact lens measurement using optical coherence tomography
    Davidson, Bryan R.
    Barton, Jennifer K.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VII, 2009, 7169
  • [7] Ultra-high speed and ultra-high resolution optical coherence tomography and optical Doppler tomography
    de Boer, JF
    Cense, B
    Nassif, N
    White, BR
    Park, BH
    Pierce, MC
    Tearney, GJ
    Bouma, BE
    Chen, TC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U414 - U414
  • [8] Ultra-high speed and ultra-high resolution optical coherence tomography and optical Doppler tomography
    de Boer, JF
    Cense, B
    Nassif, N
    White, BR
    Park, BH
    Pierce, MC
    Tearney, GJ
    Bouma, BE
    Chen, TC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [9] Accuracy and Repeatability of Ultra-High Resolution Optical Coherence Tomography
    Hutchings, N.
    Hyun, C.
    Mishra, A.
    Bizheva, K.
    Simpson, T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [10] Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography
    Cui, Lele
    Li, Ming
    Shen, Meixiao
    Lu, Fan
    Wang, Jianhua
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017