Calibrating the CsI(Tl) detectors of the GARFIELD apparatus

被引:4
|
作者
Abbondanno, U
Bruno, M
Casini, G
Cavaletti, R
Cavallaro, S
Chiari, M
D'Agostino, M
Gramegna, F
Lanchais, A
Margagliotti, GV
Mastinu, PF
Milazzo, PM
Moroni, A
Nannini, A
Ordine, A
Vannini, G
Vannucci, L
机构
[1] Ist Nazl Fis Nucl, Sez Trieste, I-34127 Trieste, Italy
[2] Univ Trieste, Dipartimento Fis, I-34127 Trieste, Italy
[3] Univ Bologna, Dipartimento Fis, Bologna, Italy
[4] Ist Nazl Fis Nucl, Sez Bologna, I-40126 Bologna, Italy
[5] Ist Nazl Fis Nucl, Sez Firenze, I-50125 Florence, Italy
[6] Univ Florence, Dipartimento Fis, Florence, Italy
[7] Univ Catania, Dipartimento Fis, Ist Nazl Fis Nucl, Sez Catania, Catania, Italy
[8] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95129 Catania, Italy
[9] Ist Nazl Fis Nucl, Lab Nazl Legnaro, I-35020 Legnaro, Italy
[10] Ist Nazl Fis Nucl, Sez Milano, I-20133 Milan, Italy
[11] Ist Nazl Fis Nucl, Sez Napoli, Naples, Italy
[12] Univ Naples, Dipartimento Fis, Naples, Italy
关键词
heavy ion; scintillation detectors; energy calibration;
D O I
10.1016/S0168-9002(02)00564-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The energy and charge dependence of the light output of the CSI(Tl) detectors of the GARFIELD apparatus has been investigated for heavy ions with 5 less than or equal to Z less than or equal to 16 in the energy range from 2.2 to 8.3 A MeV. The results have been compared to an analytical expression successfully used in previous calibration procedures at higher energies, and a rather good agreement was obtained between measured and calculated quantities. The resulting parameter set was successfully applied to another set of experimental data. The overall result demonstrates the validity of the above mentioned calibration procedure in a wide range of incident ion energies and masses. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:604 / 609
页数:6
相关论文
共 50 条
  • [21] YAP:Ce and CsI(Tl) detectors for dielectronic recombination experiment at the CSRm
    Wen, W. Q.
    Ma, X.
    Xu, W. Q.
    Meng, L. J.
    Zhu, X. L.
    Gao, Y.
    Wang, S. L.
    Zhang, P. J.
    Zhao, D. M.
    Liu, H. P.
    Zhu, L. F.
    Yang, X. D.
    Li, J.
    Ma, X. M.
    Yan, T. L.
    Yang, J. C.
    Yuan, Y. J.
    Xia, J. W.
    Xu, H. S.
    Xiao, G. Q.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 317 : 731 - 733
  • [22] Study of scintillation properties and performance of CsI(Tl) detectors over time
    Garcia-Jimenez, G.
    Cabanelas, P.
    Gonzalez-Caamano, D.
    Alvarez-Pol, H.
    Vicente-Pardal, M. A.
    Benlliure, J.
    Cederkall, J.
    Cortina-Gil, D.
    Feijoo-Fontan, M.
    Grana-Gonzalez, A.
    Rodriguez-Sanchez, J. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1059
  • [23] Absolute light and resolution measurements for sensitive CsI(Tl)/photodiode detectors
    Meier, MM
    X-RAY AND GAMMA-RAY DETECTORS AND APPLICATIONS IV, 2002, 4784 : 218 - 226
  • [24] CsI(Tl) plus photodiode scintillation assemblies for γ-ray and proton detectors
    Kudin, A. M.
    Borodenko, Yu. A.
    Grinyov, B. V.
    Didenko, A. V.
    Dudnik, A. V.
    Zaslavsky, B. G.
    Valtonen, E.
    Eronen, T.
    Peltonen, J.
    Lehti, J.
    Kettunen, H.
    Virtanen, A.
    Huovelin, J.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2010, 53 (01) : 39 - 44
  • [25] Silicon drift detectors coupled to CSI(Tl) scintillators for spaceborne gamma-ray detectors
    Marisaldi, M
    Fiorini, C
    Labanti, C
    Longoni, A
    Perotti, F
    Rossi, E
    Soltau, H
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 : 190 - 193
  • [26] Design and implementation of the NaI(Tl)/CsI(Na) detectors output signal generator
    周旭
    刘聪展
    赵建领
    张飞
    张翼飞
    李正伟
    张硕
    李旭芳
    路雪峰
    许振玲
    卢方军
    Chinese Physics C, 2014, (02) : 51 - 55
  • [27] NAI(TL) - CSI(NA) PHOSWICH DETECTORS FOR X-RAY ASTRONOMY
    KURFESS, JD
    JOHNSON, WN
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) : 626 - 632
  • [28] Design and implementation of the NaI(Tl)/CsI(Na) detectors output signal generator
    Zhou Xu
    Liu Cong-Zhan
    Zhao Jian-Ling
    Zhang Fei
    Zhang Yi-Fei
    Li Zheng-Wei
    Zhang Shuo
    Li Xu-Fang
    Lu Xue-Feng
    Xu Zhen-Ling
    Lu Fang-Jun
    CHINESE PHYSICS C, 2014, 38 (02)
  • [29] Design and implementation of the NaI(Tl)/CsI(Na) detectors output signal generator
    周旭
    刘聪展
    赵建领
    张飞
    张翼飞
    李正伟
    张硕
    李旭芳
    路雪峰
    许振玲
    卢方军
    Chinese Physics C, 2014, 38 (02) : 51 - 55
  • [30] Stability of spectrometric characteristics of CsI:Tl detectors depending on the surface treatment method
    Vydai, YT
    Tarasov, VA
    Kudin, AM
    Andryushchenko, LA
    Ananenko, AA
    Kilimchuk, IV
    Boyarintsev, AY
    Klimov, AV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2006, 49 (03) : 314 - 317