The cold neutron tomography set-up at SINQ

被引:6
|
作者
Materna, T [1 ]
Baechler, S
Jolie, J
Masschaele, B
Dierick, M
Kardjilov, N
机构
[1] Univ Cologne, Inst Kernphys, D-50937 Cologne, Germany
[2] Univ Fribourg, Dept Phys, CH-1700 Fribourg, Switzerland
[3] State Univ Ghent, Vakgrp Subatomaire & Stralingsfys, B-9000 Ghent, Belgium
[4] Tech Univ Munich, Fak Phys E21, D-85747 Garching, Germany
关键词
neutron tomography;
D O I
10.1016/j.nima.2004.03.127
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The cold neutron tomography station operated at SINQ (Paul Scherrer Institute, Switzerland) is reviewed. The high neutron flux together with a set-up based on a scintillator screen and a CCD camera yielded fast and effective results with resolution down to 250 mum: tomography of small samples (up to 2 cm large) could be performed in less than an hour. The use of a velocity selector improved the contrast discrimination and allows dichromatic tomography. The station is moving to the new research reactor FRM-II (Garching, Germany) where its performances will be increased by the availability of a 5-times-higher cold neutron flux. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:69 / 73
页数:5
相关论文
共 50 条
  • [31] Experimental set-up
    Prace Naukowe Instytutu Technologii Budowy Maszyn Politechniki Wroclawskiej, 1991, 48 (13):
  • [32] A HYBRID SET-UP OPTIMIZATION MODEL FOR TANDEM COLD ROLLING MILL
    Mirmohammadi, Mohammad Hadi
    Haddad, Hossein
    Naghavi, Seyed Mehdi
    ICINCO 2009: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS, VOL 1: INTELLIGENT CONTROL SYSTEMS AND OPTIMIZATION, 2009, : 49 - +
  • [33] Adequacy of Cold Rolling Models to Upgrade Set-up Generation Systems
    Ferreira, Henrique Cezar
    De Avila Pires, Carlos Thadeu
    Sales, Roberto Moura
    ISIJ INTERNATIONAL, 2008, 48 (10) : 1389 - 1393
  • [34] CNR -: the new beamline for cold neutron imaging at the Swiss spallation neutron source SINQ
    Kühne, G
    Frei, G
    Lehmann, E
    Vontobel, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 542 (1-3): : 264 - 270
  • [35] Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins
    Rudat, Volker
    Hammoud, Mohamed
    Pillay, Yogin
    Alaradi, Abdul Aziz
    Mohamed, Adel
    Altuwaijri, Saleh
    RADIATION ONCOLOGY, 2011, 6
  • [36] Adaptive set-up correction (ASC) to account for set-up errors in prostate radiotherapy
    Lauve, A
    Siebers, J
    Crimaldi, A
    Hagan, M
    Keall, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S332 - S332
  • [37] Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins
    Volker Rudat
    Mohamed Hammoud
    Yogin Pillay
    Abdul Aziz Alaradi
    Adel Mohamed
    Saleh Altuwaijri
    Radiation Oncology, 6
  • [38] Separating the polarizing power from depolarization in a set-up with 3 neutron polarizers
    Por, P.T.
    Kraan, W.H.
    Rekveldt, M.Th.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A339 (03) : 550 - 555
  • [39] SEPARATING THE POLARIZING POWER FROM DEPOLARIZATION IN A SET-UP WITH 3 NEUTRON POLARIZERS
    POR, PT
    KRAAN, WH
    REKVELDT, MT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (03): : 550 - 555
  • [40] Design of the testing set-up for a nuclear fuel rod by neutron radiography at CARR
    Wei, Guohai
    Han, Songbai
    Wang, Hongli
    Hao, Lijie
    Wu, Meimei
    He, Linfeng
    Wang, Yu
    Liu, Yuntao
    Sun, Kai
    Chen, Dongfeng
    7TH INTERNATIONAL TOPICAL MEETING ON NEUTRON RADIOGRAPHY (ITMNR-7), 2013, 43 : 307 - 313