Exposure assessment of the pharmaceutical diclofenac based on long-term measurements of the aquatic input

被引:71
|
作者
Letzel, Marion [1 ]
Metzner, Gerhard [1 ]
Letzel, Thomas [2 ]
机构
[1] Bavarian Environm Agcy, D-80636 Munich, Germany
[2] Tech Univ Munich, Analyt Res Grp, Chair Biopolymer Chem, D-85354 Freiberg, Germany
关键词
Pharmaceuticals; Diclofenac; Exposure assessment; ATV water quality model; Sewage treatment plants; Surface water; Mass flux; WASTE-WATER TREATMENT; ANTIINFLAMMATORY DRUG DICLOFENAC; SEWAGE-TREATMENT PLANTS; CLOFIBRIC ACID; SURFACE WATERS; MASS-SPECTROMETRY; RAINBOW-TROUT; PART; CARBAMAZEPINE; IBUPROFEN;
D O I
10.1016/j.envint.2008.09.002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Although various single-concentration measurements of the pharmaceutical diclofenac are available in literature, detailed information on the mass flux in the aquatic environment is often missing. Therefore, the overall load of diclofenac was obtained by recording each concentration in nine effluents of sewage treatment plants (STP) and at three river sites located in the area of the river Main (Germany) over a time period of six weeks. In STP effluents, concentrations of up to 2200 ng/L were obtained. In combination with flow rates and connected population an average specific load per capita and day of 0.28 mg (+/-0.11 mg) diclofenac reaches the receiving water course. This average specific load per capita is an expressive parameter to assess main diclofenac exposure to the aquatic environment avoiding uncertainties of estimated data commonly used in exposure assessment. Accordingly, predicted environmental concentrations (PEC) of 140 ng/L for a realistic worst case scenario and 2 to 52 ng/L based on water quality modeling were derived. Since concentrations of up to 140 ng/L were observed in surface water, the obtained PEC is in perfect agreement with measured concentrations. Hence, comparing the PEC with published predicted no effect concentrations (PNEC), chronic adverse effects in fish populations may occur. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:363 / 368
页数:6
相关论文
共 50 条
  • [41] Long-term metal fume exposure assessment of workers in a shipbuilding factory
    Wang, Ying-Fang
    Kuo, Yu-Chieh
    Wang, Lin-Chi
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [42] Impact assessment of long-term chronic radiation exposure on plant populations
    Geras'kin, S.
    Oudalova, A.
    Dikareva, N.
    Dikarev, V
    Prytkova, J.
    Chernonog, E.
    Novikova, T.
    RADIOPROTECTION, 2011, 46 (06) : S341 - S347
  • [43] Assessment of Effects of the Long-Term Exposure of Agricultural Crops to Carbon Nanotubes
    Lahiani, Mohamed H.
    Nima, Zeid A.
    Villagarcia, Hector
    Bilis, Alexandru S.
    Khodakovskaya, Mariya V.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2018, 66 (26) : 6654 - 6662
  • [44] Benzene exposure and hematopoietic mortality: A long-term epidemiologic risk assessment
    Rinsky, RA
    Hornung, RW
    Silver, SR
    Tseng, CY
    AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 2002, 42 (06) : 474 - 480
  • [45] Long-term exposure to environmental tobacco smoke: Assessment and contributing factors
    Misailidi, M.
    Flouris, A. D.
    ARCHIVES OF HELLENIC MEDICINE, 2012, 29 (02): : 174 - 186
  • [46] Assessment of polyester concrete subjected to long-term exposure to an acidic environment
    Sokolowska, Joanna Julia
    Zalegowski, Kamil
    OCHRONA PRZED KOROZJA, 2024, 67 (09):
  • [47] Mars radiation risk assessment and shielding design for long-term exposure
    Tripathi, Ram K.
    Nealy, John E.
    2008 IEEE AEROSPACE CONFERENCE, VOLS 1-9, 2008, : 2733 - 2741
  • [48] EXPOSURE ASSESSMENT FOR COHORT STUDIES ON LONG-TERM EFFECTS OF AIR POLLUTION
    Ranzi, A.
    Galassi, C.
    Raffaele, D.
    Gilardetti, M.
    Lauriola, P.
    Cesaroni, G.
    Forastiere, F.
    Caputo, L.
    Licitra, G.
    Tava, M.
    Tonidandel, G.
    EPIDEMIOLOGIA & PREVENZIONE, 2010, 34 (5-6): : 156 - 157
  • [49] Geotechnical measurements for the assessment of the kinematic and long-term behaviour of unstable mountainsides
    Moser, M
    GEOTECHNICAL MEASUREMENTS AND MODELLING, 2003, : 217 - 223
  • [50] Assessment of environmental noise from long-term window microphone measurements
    Jagniatinskis, A.
    Fiks, B.
    APPLIED ACOUSTICS, 2014, 76 : 377 - 385