Blood Pressure Measurements and Carotid Intima Media Thickness in Hemodialysis Patients

被引:12
|
作者
Ekart, Robert [2 ]
Hojs, Radovan [1 ]
Pecovnik-Balon, Breda [1 ]
Bevc, Sebastjan [2 ]
Dvorsak, Benjamin [1 ]
机构
[1] Univ Med Ctr Maribor, Clin Internal Med, Dept Nephrol, Maribor, Slovenia
[2] Univ Med Ctr Maribor, Clin Internal Med, Dept Dialysis, Maribor, Slovenia
关键词
Ambulatory blood pressure monitoring; Hemodialysis; Hypertension; Intima media thickness; STAGE RENAL-DISEASE; HYPERTENSION; ATHEROSCLEROSIS; MORTALITY;
D O I
10.1111/j.1744-9987.2009.00726.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In hemodialysis (HD) patients, routine dialysis center blood pressure (BP) measurements may be a poor indicator of BP control. Ambulatory blood pressure monitoring (ABPM) improves the predictability of BP as a risk factor for target organ damage. Carotid intima-media thickness (IMT) is an important indicator of asymptomatic atherosclerosis and a predictor of cardiovascular events. The purpose of our study was to evaluate the possible association between different BP measurements and carotid IMT in HD patients. Eighty-five HD patients were included in our study. BP was measured with a standard mercury sphygmomanometer before and after each HD session. The average one-monthly values of routine BP measurements were also analyzed. 24- and 48-h ABPM was performed after the end of each HD session using non-invasive ABPM. The average values of systolic and diastolic BP were analyzed separately for the first (HD) and second (interdialytic) days ABPM, and for both days together. Using B-mode ultrasonography, carotid IMT was measured and plaque occurrence investigated. We found a statistically significant correlation between carotid IMT and the average one-monthly pre-HD diastolic BP (P < 0.05), diastolic BP on the HD-day ABPM, the interdialytic-day ABPM, and during 48-h ABPM (P < 0.05). By multiple regression analysis, we found a statistically significant correlation only between carotid IMT and diastolic BP on the HD-day ABPM, the interdialytic-day ABPM, and during 48-h ABPM (P < 0.05). Only longer BP measurements (24- and 48-h ABPM) were associated with carotid IMT in HD patients.
引用
收藏
页码:288 / 293
页数:6
相关论文
共 50 条
  • [41] Reproducibility of Sonographic Measurements of Carotid Intima-Media Thickness
    Velazquez, F.
    Berna, J. D.
    Abellan, J. L.
    Serrano, L.
    Escribano, A.
    Canteras, M.
    ACTA RADIOLOGICA, 2008, 49 (10) : 1162 - 1166
  • [42] THE EFFECT OF NIGHTTIME BLOOD PRESSURE VARIABILITY ON LEFT VENTRICULAR HYPERTROPHY AND CAROTID INTIMA MEDIA THICKNESS IN PATIENTS WITH NSTEMI
    Kataoka, Shunsuke
    Okada, Kozo
    Gohbara, Masaomi
    Iwahashi, Noriaki
    Tsukahara, Kengo
    Tahara, Yoshio
    Hibi, Kiyoshi
    Kosuge, Masami
    Ebina, Toshiaki
    Umemura, Satoshi
    Kimura, Kazuo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1475 - E1475
  • [43] Relationship of short-term blood pressure variability with carotid intima-media thickness in hypertensive patients
    Yujie Chen
    Huahua Xiong
    Dan Wu
    Sandeep Pirbhulal
    Xiaohong Tian
    Ruiqin Zhang
    Minhua Lu
    Wanqing Wu
    Wenhua Huang
    BioMedical Engineering OnLine, 14
  • [44] Relationship of short-term blood pressure variability with carotid intima-media thickness in hypertensive patients
    Chen, Yujie
    Xiong, Huahua
    Wu, Dan
    Pirbhulal, Sandeep
    Tian, Xiaohong
    Zhang, Ruiqin
    Lu, Minhua
    Wu, Wanqing
    Huang, Wenhua
    BIOMEDICAL ENGINEERING ONLINE, 2015, 14
  • [45] The relation between hemoglobin variability and carotid intima-media thickness in chronic hemodialysis patients
    Ganidagli, Safa Ersen
    Altunoren, Orcun
    Erken, Ertugrul
    Isik, Ismet Onder
    Ganidagli, Berivan
    Eren, Necmi
    Yavuz, Yasemin Coskun
    Gungor, Ozkan
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2017, 49 (10) : 1859 - 1866
  • [46] CAROTID INTIMA-MEDIA THICKNESS PREDICTS DIALYSIS VASCULAR ACCESS FAILURE IN HEMODIALYSIS PATIENTS
    Lee, Hong Joo
    Han, Sang Jo
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2017, 32
  • [47] The relation between hemoglobin variability and carotid intima-media thickness in chronic hemodialysis patients
    Safa Ersen Ganidagli
    Orcun Altunoren
    Ertuğrul Erken
    Ismet Onder Isık
    Berivan Ganidagli
    Necmi Eren
    Yasemin Coskun Yavuz
    Ozkan Gungor
    International Urology and Nephrology, 2017, 49 : 1859 - 1866
  • [48] Different risk factors for the maximum and the mean carotid intima-media thickness in hemodialysis patients
    Nakashima, A
    Yorioka, N
    Asakimori, Y
    Ito, T
    Masaki, T
    Shigemoto, K
    Harada, S
    INTERNAL MEDICINE, 2003, 42 (11) : 1095 - 1099
  • [49] Impact of Carotid Intima-Media Thickness on Long-term Outcome in Hemodialysis Patients
    Patel, Munna Lal
    Co, Radheyshyam
    Verma, Amita
    Sachan, Rekha
    Kamal, Ritul
    NORTH AMERICAN JOURNAL OF MEDICAL SCIENCES, 2015, 7 (06) : 281 - 287
  • [50] Carotid Intima-Media Thickness in Maintenance Hemodialysis Patients Role of Cardiovascular Risk Factor
    Ossareh, Shahrzad
    Alaei, Anoosha
    Saedi, Daryoush
    IRANIAN JOURNAL OF KIDNEY DISEASES, 2011, 5 (03) : 169 - 174