Active vibration control for seismic excited building structures under actuator saturation, measurement stochastic noise and quantisation

被引:21
|
作者
Xu, Lanlan [1 ]
Yu, Yunyan [1 ]
Cui, Yanliang [2 ]
机构
[1] Lanzhou Jiaotong Univ, Sch Civil Engn, Lanzhou 730070, Gansu, Peoples R China
[2] Lanzhou Jiaotong Univ, Sch Mech Engn, Lanzhou 730070, Gansu, Peoples R China
基金
美国国家科学基金会;
关键词
Active vibration control; Building structure; Stochastic noise; Quantisation; Actuator saturation; H-2/H-infinity performance; TUNED MASS DAMPERS; SEMIACTIVE FUZZY CONTROL; STATIC-OUTPUT-FEEDBACK; TIME-VARYING DELAY; STABILITY ANALYSIS; INPUT SATURATION; DEPENDENT NOISE; SYSTEMS; STABILIZATION; CONSENSUS;
D O I
10.1016/j.engstruct.2017.11.021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the active vibration control for seismic excited building structures in presenting of actuator saturation, stochastic measurement noise and quantisation. The active vibration controllers are placed in some storeys, meanwhile, some active tuned mass dampers (ATMDs) are also installed at the top floor and oscillating under their control forces. All of the control forces are generated by actuators which are only capable of providing limited outputs. Since the system states are difficult or barely impossible to be accurately measured, an observer based control law is proposed to guarantee system stability, meanwhile, an H-2/H-infinity index is employed for further improving the control performance. By the proposed control strategy, the mean square exponentially stability of close-looped system can be guaranteed almost surely while the desired H-2/H-infinity performance can be achieved simultaneously. In addition, the convergence rate of system state can be pre-scheduled. By regulating the different locations of sensors and controllers, the vibration response can be mitigated in different level. Numerical examples are provided to demonstrate the effectiveness of the proposed method.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [41] Active Vibration Control of Container Cranes Against Earthquake by the Use of Delay-Dependent H∞ Controller Under Consideration of Actuator Saturation
    Yazici, Hakan
    Azeloglu, C. Oktay
    Kucukdemiral, I. Beklan
    JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL, 2014, 33 (03) : 289 - 316
  • [42] Experimental verification of active control for a seismic-excited full-sealed building
    Loh, CH
    Lin, PY
    Chung, NH
    IMAC - PROCEEDINGS OF THE 17TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS I AND II, 1999, 3727 : 444 - 450
  • [43] Active vibration control of large space flexible slewing truss using cable actuator with input saturation
    Jin, Qi-Bao
    Huang, Jin
    INTERNATIONAL JOURNAL OF ROBUST AND NONLINEAR CONTROL, 2018, 28 (02) : 504 - 518
  • [44] Stability analysis of active vibration control of building structures using PD/PID control
    Thenozhi, Suresh
    Yu, Wen
    ENGINEERING STRUCTURES, 2014, 81 : 208 - 218
  • [45] Active control of noise and vibration in acoustic ducts and flexible structures - a Spatial Control approach
    Moheimani, SOR
    Pota, HR
    Petersen, IR
    PROCEEDINGS OF THE 1998 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 1998, : 2601 - 2605
  • [46] Numerical design of optimal active control for seismically-excited building structures
    Marinova, D
    Marinov, V
    NUMERICAL ANALYSIS AND ITS APPLICATIONS, 2005, 3401 : 408 - 415
  • [47] Vibration control of uncertain structures with actuator saturation using hedge-algebras-based fuzzy controller
    Hai-Le Bui
    Cong-Hung Nguyen
    Van-Binh Bui
    Kim-Ngoc Le
    Huu-Quoc Tran
    JOURNAL OF VIBRATION AND CONTROL, 2017, 23 (12) : 1984 - 2002
  • [48] Improved Decentralized Method for Control of Building Structures under Seismic Excitation
    Ma, Tian-Wei
    Johansen, Jeremy
    Xu, Ning-Shou
    Yang, Henry T. Y.
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2010, 136 (05): : 662 - 673
  • [49] Stochastic optimal design of novel nonlinear base isolation system for seismic-excited building structures
    Shan, Jiazeng
    Shi, Zhiguo
    Hu, Fan
    Yu, Jian
    Shi, Weixing
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (07):
  • [50] Preventing stroke saturation of inertial actuators used for active vibration control of floor structures
    Ahmadi, Mohammad Wasi
    STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (07):