Active vibration control for seismic excited building structures under actuator saturation, measurement stochastic noise and quantisation

被引:21
|
作者
Xu, Lanlan [1 ]
Yu, Yunyan [1 ]
Cui, Yanliang [2 ]
机构
[1] Lanzhou Jiaotong Univ, Sch Civil Engn, Lanzhou 730070, Gansu, Peoples R China
[2] Lanzhou Jiaotong Univ, Sch Mech Engn, Lanzhou 730070, Gansu, Peoples R China
基金
美国国家科学基金会;
关键词
Active vibration control; Building structure; Stochastic noise; Quantisation; Actuator saturation; H-2/H-infinity performance; TUNED MASS DAMPERS; SEMIACTIVE FUZZY CONTROL; STATIC-OUTPUT-FEEDBACK; TIME-VARYING DELAY; STABILITY ANALYSIS; INPUT SATURATION; DEPENDENT NOISE; SYSTEMS; STABILIZATION; CONSENSUS;
D O I
10.1016/j.engstruct.2017.11.021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the active vibration control for seismic excited building structures in presenting of actuator saturation, stochastic measurement noise and quantisation. The active vibration controllers are placed in some storeys, meanwhile, some active tuned mass dampers (ATMDs) are also installed at the top floor and oscillating under their control forces. All of the control forces are generated by actuators which are only capable of providing limited outputs. Since the system states are difficult or barely impossible to be accurately measured, an observer based control law is proposed to guarantee system stability, meanwhile, an H-2/H-infinity index is employed for further improving the control performance. By the proposed control strategy, the mean square exponentially stability of close-looped system can be guaranteed almost surely while the desired H-2/H-infinity performance can be achieved simultaneously. In addition, the convergence rate of system state can be pre-scheduled. By regulating the different locations of sensors and controllers, the vibration response can be mitigated in different level. Numerical examples are provided to demonstrate the effectiveness of the proposed method.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [1] Acceleration feedback active vibration control for seismic excited building structures with actuator saturation
    Xu, Lanlan
    Yu, Yunyan
    Cui, Yanliang
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 115 : 472 - 475
  • [2] Active tuned mass damper based vibration control for seismic excited adjacent buildings under actuator saturation
    Xu, Lanlan
    Cui, Yanliang
    Wang, Zhenglu
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2020, 135
  • [3] Application of active control to buildings under seismic excitation: Actuator saturation
    Nguyen, T
    Jabbari, F
    de Miguel, S
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, VOLS 1 AND 2, 1996, : 1051 - 1055
  • [4] Actuator saturation during active vibration control of milling
    Ozsoy, Muhammet
    Sims, Neil D.
    Ozturk, Erdem
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2025, 224
  • [5] ACTIVE CONTROL OF BUILDING STRUCTURES UNDER MEASURED SEISMIC LOADS.
    Rodellar, J.
    Barbat, A.H.
    1600, (02):
  • [6] Seismic response control of building structures under pulse-type ground motions by active vibration controller
    Elias, Said
    Djerouni, Salah
    De Domenico, Dario
    Abdeddaim, Mahdi
    El Ouni, Mohamed Hechmi
    JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL, 2023, 42 (01) : 345 - 367
  • [7] Actuator saturation and control design for buildings under seismic excitation
    Kim, JH
    Jabbari, F
    JOURNAL OF ENGINEERING MECHANICS, 2002, 128 (04) : 403 - 412
  • [8] Actuator saturation and control design for buildings under seismic excitation
    Kim, JH
    Jabbari, F
    Yang, JN
    PROCEEDINGS OF THE 2000 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2000, : 29 - 33
  • [9] Active Vibration Control of Seismically Excited Building Structures by Upgraded Grey Wolf Optimizer
    Azizi, Mahdi
    Talatahari, Siamak
    Giaralis, Agathoklis
    IEEE ACCESS, 2021, 9 : 166658 - 166673
  • [10] Application of LIPCA as actuator for active vibration control of dynamic structures
    Suhariyono, A
    Goo, NS
    Park, HC
    Yoon, KJ
    SMART STRUCTURES AND MATERIALS 2005: DAMPING AND ISOLATION, 2005, 5760 : 510 - 517