Calibration of accelerometers:: determination of amplitude and phase response upon shock excitation

被引:36
|
作者
Link, A.
Taeubner, A.
Wabinski, W.
Bruns, T.
Elster, C.
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
[2] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
关键词
D O I
10.1088/0957-0233/17/7/030
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A novel approach is proposed for the analysis of shock calibration measurements of accelerometers. The input/output behaviour of an accelerometer is represented by a physical model in terms of a second-order differential equation. The unknown model parameters, i.e. the coefficients of the differential equation, are estimated by a frequency domain least-squares approach. The derived model is then used to determine the frequency response of the accelerometer. The method was applied to calibration measurements upon shock excitations of two back-to-back accelerometers (ENDEVCO type 2270 and Bruel & Kjaer type 8305). The determined frequency response was then compared to additional calibration measurements upon sinusoidal excitation. The sinusoidal excitation measurements were analysed by means of the established sine approximation method. Consistent results were obtained by the two methods which confirm the validity of the proposed modelling approach.
引用
收藏
页码:1888 / 1894
页数:7
相关论文
共 50 条
  • [31] Determination of the Hydrophone Phase-Frequency Response by its Amplitude-Frequency Response
    Isaev, A. E.
    Khatamtaev, B., I
    MEASUREMENT TECHNIQUES, 2021, 64 (07) : 580 - 585
  • [32] Determination of the Hydrophone Phase-Frequency Response by its Amplitude-Frequency Response
    A. E. Isaev
    B. I. Khatamtaev
    Measurement Techniques, 2021, 64 : 580 - 585
  • [33] AMPLITUDE AND PHASE NON-LINEAR RESPONSE OF BLEACHABLE DYES USING PICOSECOND EXCITATION
    VASILEVA, MA
    VISHCHAKAS, J
    GULBINAS, V
    MALYSHEV, VI
    MASALOV, AV
    KABELKA, V
    SYRUS, V
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1983, 19 (04) : 724 - 730
  • [34] Amplitude and phase calibration of hydrophones up to 70 MHz using broadband pulse excitation and an optical reference hydrophone
    Wilkens, V
    Koch, C
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (06): : 2892 - 2903
  • [35] Optimal control design of constant amplitude phase-modulated pulses: Application to calibration-free broadband excitation
    Skinner, TE
    Kobzar, K
    Luy, B
    Bendall, MR
    Bermel, W
    Khaneja, N
    Glaser, SJ
    JOURNAL OF MAGNETIC RESONANCE, 2006, 179 (02) : 241 - 249
  • [36] A Method for Amplitude and Phase Calibration in a Spaceborne Multibeam Receiver
    Huang, Zhigang
    Qiao, Chunjie
    Wang, Yueke
    CHINA SATELLITE NAVIGATION CONFERENCE (CSNC) 2014 PROCEEDINGS, VOL I, 2014, 303 : 487 - 496
  • [37] PHASE AND AMPLITUDE CALIBRATION IN APERTURE SYNTHESIS - ALGEBRAIC STRUCTURES
    LANNES, A
    INVERSE PROBLEMS, 1991, 7 (02) : 261 - 298
  • [38] Calibration of mixer amplitude and phase imbalance in superconducting circuits
    Jolin, S. W.
    Borgani, R.
    Tholen, M. O.
    Forchheimer, D.
    Haviland, D. B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (12):
  • [39] A quadrature oscillator using simplified phase and amplitude calibration
    Jonsson, Fredrik
    Olsson, Hakan
    PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10, 2008, : 992 - 995
  • [40] Prediction of response amplitude to vortex-induced excitation
    Fujisawa, Nobumitsu
    Takeda, Katsuaki
    NKK Technical Review, 1993, (67): : 32 - 37