A novel approach is proposed for the analysis of shock calibration measurements of accelerometers. The input/output behaviour of an accelerometer is represented by a physical model in terms of a second-order differential equation. The unknown model parameters, i.e. the coefficients of the differential equation, are estimated by a frequency domain least-squares approach. The derived model is then used to determine the frequency response of the accelerometer. The method was applied to calibration measurements upon shock excitations of two back-to-back accelerometers (ENDEVCO type 2270 and Bruel & Kjaer type 8305). The determined frequency response was then compared to additional calibration measurements upon sinusoidal excitation. The sinusoidal excitation measurements were analysed by means of the established sine approximation method. Consistent results were obtained by the two methods which confirm the validity of the proposed modelling approach.
引用
收藏
页码:1888 / 1894
页数:7
相关论文
共 50 条
  • [2] Calibration of accelerometers by shock excitation and laser interferometry
    Link, A
    von Martens, HJ
    SHOCK AND VIBRATION, 2000, 7 (02) : 101 - 112
  • [3] Amplitude and phase calibration of accelerometers in the nanometer range
    Link, A
    Gerhardt, J
    vonMartens, HJ
    SECOND INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 1996, 2868 : 37 - 48
  • [4] Modelling accelerometers for transient signals using calibration measurements upon sinusoidal excitation
    Link, A.
    Taeubner, A.
    Wabinski, W.
    Bruns, T.
    Elster, C.
    MEASUREMENT, 2007, 40 (9-10) : 928 - 935
  • [5] Shock and vibration calibration of accelerometers
    Peres, M
    Sill, RD
    SOUND AND VIBRATION, 2006, 40 (03): : 8 - +
  • [6] Calibration of Accelerometers Using Multisinusoidal Excitation
    Buchczik, Dariusz
    Pawelczyk, Marek
    ADVANCES IN CONDITION MONITORING OF MACHINERY IN NON-STATIONARY OPERATIONS, CMMNO 2016, 2018, 9
  • [7] Calibration of accelerometers with impact excitation and reference method
    Müller, H
    TECHNISCHES MESSEN, 2003, 70 (06): : 286 - 293
  • [8] New method for absolute shock calibration of accelerometers
    Link, A
    von Martens, HJ
    Wabinski, W
    THIRD INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 1998, 3411 : 224 - 235
  • [9] A simple method for amplitude/phase calibration of tri-axial accelerometers in the low frequency range
    D'Emilia, G.
    Gaspari, A.
    Natale, E.
    13TH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER AND NONCONTACT TECHNIQUES, 2018, 2018, 1149
  • [10] Uncertainty evaluation of a primary shock calibration method for accelerometers
    Ueda, K
    Umeda, A
    Imai, H
    METROLOGIA, 2000, 37 (03) : 187 - 197