Applicability of cloud point extraction for the separation trace amount of lead ion in environmental and biological samples prior to determination by flame atomic absorption spectrometry

被引:27
|
作者
Mohammadi, Sayed Zia [1 ,2 ]
Shamspur, Tayebeh [3 ]
Afzali, Daryoush [4 ]
Taher, Mohammad Ali [3 ]
Baghelani, Yar Mohammad [2 ]
机构
[1] Payame Noor Univ, Dept Chem, Bam, Iran
[2] Payame Noor Univ, Dept Chem, Kerman, Iran
[3] Shahid Bahonar Univ, Dept Chem, Kerman, Iran
[4] Int Ctr Sci High Technol Environm Sci, Kerman, Iran
关键词
Cloud point extraction; Preconcentration; Lead determination; WATER SAMPLES; SPECTROPHOTOMETRIC DETERMINATION; FLUORESCENCE SPECTROMETRY; CADMIUM; PRECONCENTRATION; EMISSION; CU(II); UPDATE; COPPER;
D O I
10.1016/j.arabjc.2011.07.003
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A sensitive cloud point extraction procedure(CPE) for the preconcentration of trace lead prior to its determination by flame atomic absorption spectrometry (FAAS) has been developed. The CPE method is based on the complex of Pb(II) ion with 1-(2-pyridylazo)-2-naphthol (PAN), and then entrapped in the non-ionic surfactant Triton X-114. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of PAN and Triton X-114, equilibration temperature and time, were investigated in detail. A preconcentration factor of 30 was obtained for the preconcentration of Pb(II) ion with 15.0 mL solution. Under the optimal conditions, the calibration curve was linear in the range of 7.5 ng mL(-1) -3.5 mu g mL(-1) of lead with R-2 = 0.9998 (n = 10). Detection limit based on three times the standard deviation of the blank (3S(b)) was 5.27 ng mL(-1). Eight replicate determinations of 1.0 mu g mL(-1) lead gave a mean absorbance of 0.275 with a relative standard deviation of 1.6%. The high efficiency of cloud point extraction to carry out the determination of analytes in complex matrices was demonstrated.The proposed method has been applied for determination of trace amounts of lead in biological and water samples with satisfactory results. (C) 2011 Production and hosting by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:S610 / S615
页数:6
相关论文
共 50 条
  • [21] Simultaneous preconcentration and determination of trace amount of lead and copper in water samples by flame atomic absorption spectrometry
    Mousavi, H. Zavvar
    Shirkhanloo, H.
    ASIAN JOURNAL OF CHEMISTRY, 2008, 20 (05) : 3633 - 3640
  • [22] Cloud point extraction-flame atomic absorption spectrometry method for preconcentration and determination of trace cadmium in water samples
    Ning, Jinyan
    Jiao, Yang
    Zhao, Jiao
    Meng, Lifen
    Yang, Yaling
    WATER SCIENCE AND TECHNOLOGY, 2014, 70 (04) : 605 - 611
  • [23] Cloud point extraction and flame atomic absorption spectrometry determination of trace amounts of copper(II) ions in water samples
    Fathi, S. A. M.
    Yaftian, M. R.
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2009, 334 (02) : 167 - 170
  • [24] Determination of trace lead in water samples and salt samples by graphite furnace atomic absorption spectrometry after cloud point extraction
    Zhang Yuan
    Luo Wen-hong
    Li Hui
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26 (07) : 1349 - 1351
  • [25] Determination of cadmium, copper, lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction
    Chen, JR
    Teo, KC
    ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) : 215 - 222
  • [26] Determination of manganese in mater samples by flame atomic absorption spectrometry after cloud point extraction
    Teo, KC
    Chen, JR
    ANALYST, 2001, 126 (04) : 534 - 537
  • [27] Selective cloud point extraction for the determination of cadmium in food samples by flame atomic absorption spectrometry
    Xiang, Guoqiang
    Wen, Shengping
    Wu, Xiaoyun
    Jiang, Xiuming
    He, Lijun
    Liu, Yulan
    FOOD CHEMISTRY, 2012, 132 (01) : 532 - 536
  • [28] Cloud point extraction for Co and Ni determination in water samples by flame atomic absorption spectrometry
    Lemos, Valfredo Azevedo
    da Franca, Robson Silva
    Moreira, Bruno Oliveira
    SEPARATION AND PURIFICATION TECHNOLOGY, 2007, 54 (03) : 349 - 354
  • [30] Preconcentration and determination of manganese in biological samples by dual-cloud point extraction coupled with flame atomic absorption spectrometry
    Arain, Mariam S.
    Kazi, Tasneem G.
    Afridi, Hassan I.
    Arain, Salma A.
    Ali, Jamshed
    Naeemullah
    Arain, Sadaf S.
    Panhwar, Abdul Haleem
    Shanker, Bhawani
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (12) : 2349 - 2355