Initial in vitro testing of a paediatric continuous-flow total artificial heart

被引:14
|
作者
Fukamachi, Kiyotaka [1 ]
Karimov, Jamshid H. [1 ]
Horvath, David J. [2 ]
Sunagawa, Gengo [1 ,3 ]
Byram, Nicole A. [1 ]
Kuban, Barry D. [1 ,5 ]
Moazami, Nader [4 ,6 ]
机构
[1] Cleveland Clin, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] R1 Engn, Euclid, OH USA
[3] Temple Univ, Philadelphia, PA 19122 USA
[4] Cleveland Clin, Kaufman Ctr Heart Failure, Miller Family Heart & Vasc Inst, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44106 USA
[5] Cleveland Clin, Lerner Res Inst, Med Device Solut Elect Core, Cleveland, OH 44106 USA
[6] NYU Langone Hlth, New York, NY USA
关键词
Anatomical fit; Congenital cardiomyopathy; Congenital heart disease; Paediatric devices; Paediatric transition to adult care; VENTRICULAR ASSIST DEVICES; TRANSPLANT; MORTALITY; CHILDREN; SUPPORT;
D O I
10.1093/icvts/ivx429
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. METHODS: The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. RESULTS: Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within +/- 5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. CONCLUSIONS: The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.
引用
收藏
页码:897 / 901
页数:5
相关论文
共 50 条
  • [21] Cleveland Clinic Continuous-Flow Total Artificial Heart: Progress Report and Technology Update
    Kuroda, Taiyo
    Miyagi, Chihiro
    Polakowski, Anthony R.
    Flick, Christine R.
    Kuban, Barry D.
    Fukamachi, Kiyotaka
    Karimov, Jamshid H.
    ASAIO JOURNAL, 2024, 70 (02) : 116 - 123
  • [22] Human fitting of pediatric and infant continuous-flow total artificial heart: visual and virtual assessment
    Miyagi, Chihiro
    Ahmad, Munir
    Karimov, Jamshid H.
    Polakowski, Anthony R.
    Karamlou, Tara
    Yaman, Malek
    Fukamachi, Kiyotaka
    Najm, Hani K.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [23] Implantable Continuous-Flow Total Artificial Heart for Newborns and Infants: First Report of Working Model
    Karimov, Jamshid
    Miyagi, Chihiro
    Flick, Christine
    Kuban, Barry D.
    Kuroda, Taiyo
    Fukamachi, Kiyotaka
    Karamlou, Tara K.
    Ahmad, Munir
    Najm, Hani
    CIRCULATION RESEARCH, 2023, 133 (12) : E60 - E61
  • [24] Generating pulsatility by pump speed modulation with continuous-flow total artificial heart in awake calves
    Kiyotaka Fukamachi
    Jamshid H. Karimov
    Gengo Sunagawa
    David J. Horvath
    Nicole Byram
    Barry D. Kuban
    Raymond Dessoffy
    Shiva Sale
    Leonard A. R. Golding
    Nader Moazami
    Journal of Artificial Organs, 2017, 20 : 381 - 385
  • [25] Prediction of Optimal Continuous-Flow Total Artificial Heart and Vascular Parameters to Maintain Hemodynamic Homeostasis
    McDowall, Michael T.
    Adair, Paige A.
    Knezek, Sarah F.
    Tuzun, Egemen
    Quick, Christopher M.
    FASEB JOURNAL, 2013, 27
  • [26] Generating pulsatility by pump speed modulation with continuous-flow total artificial heart in awake calves
    Fukamachi, Kiyotaka
    Karimov, Jamshid H.
    Sunagawa, Gengo
    Horvath, David J.
    Byram, Nicole
    Kuban, Barry D.
    Dessoffy, Raymond
    Sale, Shiva
    Golding, Leonard A. R.
    Moazami, Nader
    JOURNAL OF ARTIFICIAL ORGANS, 2017, 20 (04) : 381 - 385
  • [27] Anatomical study of the Cleveland Clinic continuous-flow total artificial heart in adult and pediatric configurations
    Fukamachi, Kiyotaka
    Karimov, Jamshid H.
    Byram, Nicole A.
    Sunagawa, Gengo
    Dessoffy, Raymond
    Miyamoto, Takuma
    Horvath, David J.
    JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (03) : 383 - 386
  • [28] Pulsatility hemodynamics during speed modulation of continuous-flow total artificial heart in a chronic in vivo
    Kuroda, Taiyo
    Miyamoto, Takuma
    Miyagi, Chihiro
    Polakowski, Anthony R.
    Flick, Christine R.
    Kuban, Barry D.
    Voros, George B.
    Such, Kimberly
    Fukamachi, Kiyotaka
    Karimov, Jamshid H.
    ARTIFICIAL ORGANS, 2022, 46 (08) : 1555 - 1563
  • [29] Generating Pulsatility by Pump Speed Modulation with Continuous-Flow Total Artificial Heart in Awake Calves
    Fukamachi, K.
    Karimov, J. H.
    Sunagawa, G.
    Horvath, D. J.
    Byram, N.
    Kuban, B. D.
    Dessoffy, R.
    Sale, S.
    Moazami, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S129 - S129
  • [30] Speed Modulation of the Continuous-Flow Total Artificial Heart to Simulate a Physiologic Arterial Pressure Waveform
    Shiose, Akira
    Nowak, Kathleen
    Horvath, David J.
    Massiello, Alex L.
    Golding, Leonard A. R.
    Fukamachi, Kiyotaka
    ASAIO JOURNAL, 2010, 56 (05) : 403 - 409