Evaluation of a hematology analyzer with canine and feline blood

被引:24
|
作者
Pastor, J
Cuenca, R
Velarde, P
Vinas, L
Lavin, S
机构
[1] Department of Veterinary Medicine, Facultad de Veterinaria, Univ. Autónoma de Barcelona, 08193 Bellaterra, Barcelona
关键词
hematology analyzer; electrical impedance; blood cell counter; dog; cat;
D O I
10.1111/j.1939-165X.1997.tb00726.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A semiautomatic electronic blood cell counter (Sysmex F-800:Toa Medical Electronics Europa Gmbh, Hamburg, Germany) was evaluated using canine and feline blood, following the International Committee for Standardization in Hematology protocol (ICSH, 1984). Precision and overall reproducibility were acceptable for all the parameters studied except for the feline platelet count, in which overlapping of erythrocyte and platelet populations prohibited determination of an accurate platelet count. Since carry-over from canine hematocrit values and platelet counts and from feline hematocrit values was unsatisfactory, the use of a blank diluent sample between different analyses was necessary. Linearity of the analyzer was acceptable in the studied range. Thirty canine and feline blood samples were analyzed using the Sysmex F-800 and a manual method. Correlations between both methods were acceptable for all the parameters, except for feline platelet count and erythrocyte indices for both species. In the storage study red blood cell count and hemoglobin concentration were the parameters with the longest stability (72 hours at 4 degrees C and 25 degrees C) in both species. A statistically significant increase in MCV was obtained at 12 hours post-extraction in canine samples stored at 25 degrees C and at 24 hours in refrigerated samples. Feline leucocyte counts showed a downward trend at 12 hours post-extraction at both temperatures. Canine platelet count decreased significantly at 6 hours post-extraction in samples stored at 4 degrees C. During the evaluation period, Sysmex F-800 was user friendly and appeared well suited for routine canine and feline blood cell analysis.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 50 条
  • [41] AN EVALUATION OF THE SYSMEX NE-8000 HEMATOLOGY ANALYZER
    HALLAWELL, R
    OMALLEY, C
    HUSSEIN, S
    DAUER, RJ
    TANTI, M
    WOOTTON, AM
    MCGRATH, KM
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1991, 96 (05) : 594 - 601
  • [42] EVALUATION OF THE HEMATOLOGY TEST IN THE DIAGNOSIS OF CANINE EHRLICHIOSIS
    Hoyos S, Luis
    Li E, Olga
    Alvarado S, Arnaldo
    Suarez A, Francisco
    Diaz C, Diego
    REVISTA DE INVESTIGACIONES VETERINARIAS DEL PERU, 2007, 18 (02): : 129 - 135
  • [43] Canine reference intervals for the Sysmex XT-2000iV hematology analyzer
    Bourges-Abella, Nathalie
    Geffre, Anne
    Concordet, Didier
    Braun, Jean-Pierre
    Trumel, Catherine
    VETERINARY CLINICAL PATHOLOGY, 2011, 40 (03) : 303 - 315
  • [44] Evaluation of blood cell count using an automatic hematology analyzer to optimize collection of peripheral blood progenitor cells by leukapheresis
    Pederzoli, Paula Renata Machado Passos
    Prata, Karen de Lima
    Cruz, Nathalia Gomide
    Marzano, Pedro Victorio de Almeida
    Martins, Mauricio Colombini
    Costa, Luciana de Almeida
    de Andrade, Roberta Kelly
    Libanio, Marcia Regina Issa Salomao
    Custer, Brian
    Belisario, Andre Rolim
    HEMATOLOGY TRANSFUSION AND CELL THERAPY, 2024, 46 : S150 - S156
  • [45] MONITORING OF THE WHITE BLOOD CELLS FILTRATION BY AUTOMATED HEMATOLOGY ANALYZER
    Paiboonsukwong, Kittiphong
    Trisakulwattana, Krittanai
    Faknuam, Saruta
    Pattanapanyasat, Kovit
    Fucharoen, Suthat
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 : 134 - 134
  • [46] Discordant Hemoglobin Values Determined by Blood Gas Analyzer and Hematology Analyzer Synchronously Is a Warning for Inappropriate Blood Sampling
    Aydin, Ozgur
    INDIAN JOURNAL OF CLINICAL BIOCHEMISTRY, 2022, 37 (02) : 250 - 252
  • [47] Discordant Hemoglobin Values Determined by Blood Gas Analyzer and Hematology Analyzer Synchronously Is a Warning for Inappropriate Blood Sampling
    Özgür Aydın
    Indian Journal of Clinical Biochemistry, 2022, 37 : 250 - 252
  • [48] EVALUATION OF A NEW HEMATOLOGY ANALYZER FOR WHOLE-BLOOD COUNT AND FULL DIFFERENTIAL (NE-8000)
    LAHARRAGUE, PF
    FILLOLA, G
    CORBERAND, JX
    NOUVELLE REVUE FRANCAISE D HEMATOLOGIE, 1992, 34 (04): : 303 - 307
  • [49] SERUM LEVELS OF AMYLASE AND LIPASE IN CANINE AND FELINE SPECIES ON THE ABBOTT BICHROMATIC ANALYZER
    BAJEMA, L
    CLINICAL CHEMISTRY, 1979, 25 (06) : 1113 - 1113
  • [50] Evaluation of the utility and accuracy of body fluids containing red blood cells to determine canine and feline blood types
    Garcia-Arce, Marta
    Breheny, Craig R.
    Boag, Alisdair M.
    Llewellyn, Efa A.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2023, 33 (01) : 47 - 51