Evaluation of a hematology analyzer with canine and feline blood

被引:24
|
作者
Pastor, J
Cuenca, R
Velarde, P
Vinas, L
Lavin, S
机构
[1] Department of Veterinary Medicine, Facultad de Veterinaria, Univ. Autónoma de Barcelona, 08193 Bellaterra, Barcelona
关键词
hematology analyzer; electrical impedance; blood cell counter; dog; cat;
D O I
10.1111/j.1939-165X.1997.tb00726.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A semiautomatic electronic blood cell counter (Sysmex F-800:Toa Medical Electronics Europa Gmbh, Hamburg, Germany) was evaluated using canine and feline blood, following the International Committee for Standardization in Hematology protocol (ICSH, 1984). Precision and overall reproducibility were acceptable for all the parameters studied except for the feline platelet count, in which overlapping of erythrocyte and platelet populations prohibited determination of an accurate platelet count. Since carry-over from canine hematocrit values and platelet counts and from feline hematocrit values was unsatisfactory, the use of a blank diluent sample between different analyses was necessary. Linearity of the analyzer was acceptable in the studied range. Thirty canine and feline blood samples were analyzed using the Sysmex F-800 and a manual method. Correlations between both methods were acceptable for all the parameters, except for feline platelet count and erythrocyte indices for both species. In the storage study red blood cell count and hemoglobin concentration were the parameters with the longest stability (72 hours at 4 degrees C and 25 degrees C) in both species. A statistically significant increase in MCV was obtained at 12 hours post-extraction in canine samples stored at 25 degrees C and at 24 hours in refrigerated samples. Feline leucocyte counts showed a downward trend at 12 hours post-extraction at both temperatures. Canine platelet count decreased significantly at 6 hours post-extraction in samples stored at 4 degrees C. During the evaluation period, Sysmex F-800 was user friendly and appeared well suited for routine canine and feline blood cell analysis.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 50 条
  • [1] Validation of the Celltac alpha automated hematology analyzer for canine and feline blood samples
    McDaniel, Barbara Jane
    Hirschberger, Johannes
    Weber, Karin
    VETERINARY CLINICAL PATHOLOGY, 2013, 42 (01) : 11 - 18
  • [2] Evaluation of the Mythic 18 hematology analyzer for use with canine, feline, and equine samples
    Wassmuth, Andrea K.
    Riond, Barbara
    Hofmann-Lehmann, Regina
    Lutz, Hans
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2011, 23 (03) : 436 - 453
  • [3] Precision and accuracy of the Mindray BC-5000Vet hematology analyzer for canine and feline blood
    Thongsahuan, Sorawat
    Fonghoi, Lalita
    Kaewfai, Sunita
    Srinoun, Kanitta
    VETERINARY CLINICAL PATHOLOGY, 2020, 49 (02) : 207 - 216
  • [4] Performance evaluation of the Sysmex pocH-100iV Diff hematology analyzer for analysis of canine, feline, equine, and bovine blood
    Riond, Barbara
    Weissenbacher, Stefan
    Hofmann-Lehmann, Regina
    Lutz, Hans
    VETERINARY CLINICAL PATHOLOGY, 2011, 40 (04) : 484 - 495
  • [5] Evaluation of the impedance analyzer PocH-100iV Diff for analysis of canine and feline blood
    Bauer, Natali B.
    Nakagawa, Julia
    Dunker, Cathrin
    Failing, Klaus
    Moritz, Andreas
    VETERINARY CLINICAL PATHOLOGY, 2012, 41 (02) : 194 - 206
  • [6] Evaluation of canine and feline leukocyte differential counts obtained with the scil vCell 5 compared to the Advia 2120 hematology analyzer and a manual method
    Zelmer, Kim-Lina Charlotte
    Moritz, Andreas
    Bauer, Natali
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2023, 35 (06) : 679 - 697
  • [7] Canine and feline hematology reference values for the ADVIA 120 hematology system
    Moritz, A
    Fickenscher, Y
    Meyer, K
    Failing, K
    Weiss, DJ
    VETERINARY CLINICAL PATHOLOGY, 2004, 33 (01) : 32 - 38
  • [8] Evaluation of the use of a blood analyser for canine and feline specimens
    van Leeuwen, MW
    Teske, E
    TIJDSCHRIFT VOOR DIERGENEESKUNDE, 1999, 124 (10) : 306 - 309
  • [9] Artifactual changes in canine blood following storage, detected using the ADVIA 120 hematology analyzer
    Furlanello, Tommaso
    Tasca, Silvia
    Caldin, Marco
    Carli, Erika
    Patron, Carlo
    Tranquillo, Massimo
    Lubas, George
    Solano-Gallego, Laia
    VETERINARY CLINICAL PATHOLOGY, 2006, 35 (01) : 42 - 46
  • [10] Evaluation of an in-clinic dry chemistry analyzer for canine, equine, and feline plasma samples
    Boes, Katie M.
    Sink, Carolyn A.
    Camus, Melinda S.
    Werre, Stephen R.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2018, 30 (06) : 902 - 910