An improved high-performance liquid chromatography assay for the three stereoisomers of the muscle relaxant mivacurium and its metabolites in plasma is presented. The principal steps in the assay are precipitation of plasma proteins by acetonitrile, lyophilization of the supernatant and ion-exchange chromatography on Spherisorb 5-SCX column, with gradient elution (acetonitrile from 32 to 68% v/v and ionic gradient from 7 to 56 mmol l(-1) Na2SO4), a flow-rate of 2.0 ml min(-1), D-tubocurarine as internal standard and fluorometric detection (excitation wavelength=280 nm, emission wavelength=320 nm). Quantitation limit of cis-cis, cis-trans, trans-trans isomers were 0.003, 0.002 and 0.005 mu mol l(-1), respectively. Quantitation limits for the monoester(cis) metabolite were 0.011 mu mol l(-1), for the monoester(trans) metabolite 0.017 mu mol l(-1), for the amino-alcohol(trans) 0.020 mu mol l(-1) and for the amino-alcohol(cis) 0.021 mu mol l(-1). None of eight drugs used during anaesthesia interfered with the assay in vitro. Satisfactory performance was demonstrated by the measurement of the isomers and their metabolites in plasma of two patients over a 6-h period after repeated injections of mivacurium.
引用
收藏
页码:315 / 322
页数:8
相关论文
共 50 条
  • [22] Simple high-performance liquid chromatographic assay for the determination of ciprofloxacin in human plasma with ultraviolet detection
    Maya, MT
    Gonçalves, NJ
    Silva, NB
    Morais, JA
    JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2): : 305 - 309
  • [23] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR ANTIPYRINE AND ITS METABOLITES IN PLASMA AND URINE
    BANG, TT
    BELANGER, PM
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1985, 8 (04): : C6 - C6
  • [24] DETERMINATION OF ALPIDEM AND ITS METABOLITES IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND FLUOROMETRIC DETECTION
    ASCALONE, V
    CATALANI, P
    DALBO, L
    DESCHAMPS, N
    GUINEBAULT, P
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 414 (01): : 101 - 108
  • [25] DETECTION OF NALBUPHINE IN PLASMA - AN IMPROVED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY
    KEEGAN, M
    KAY, B
    JOURNAL OF CHROMATOGRAPHY, 1984, 311 (01): : 223 - 226
  • [26] ASSAY OF MOGUISTEINE METABOLITES IN HUMAN PLASMA AND URINE - CONVENTIONAL AND CHIRAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS
    CASTOLDI, D
    OGGIONI, A
    RENOLDI, MI
    RATTI, E
    DIGIOVINE, S
    BERNAREGGI, A
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 655 (02): : 243 - 252
  • [27] SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR ENDRALAZINE AND 2 OF ITS METABOLITES IN HUMAN-PLASMA
    REECE, PA
    COZAMANIS, I
    ZACEST, R
    JOURNAL OF CHROMATOGRAPHY, 1981, 225 (01): : 151 - 160
  • [28] A SIMPLE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR LORACARBEF IN HUMAN PLASMA
    ALANGARY, AA
    ANALYTICAL LETTERS, 1995, 28 (10) : 1819 - 1831
  • [29] A validated high-performance liquid chromatographic assay for determination of lumiracoxib in human plasma
    Cheremina, Olga
    Brune, Kay
    Hinz, Burkhard
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (10) : 1033 - 1037
  • [30] High-performance liquid chromatographic assay for minocycline in human plasma and parotid saliva
    Orti, V
    Audran, M
    Gibert, P
    Bougard, G
    Bressolle, F
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 738 (02): : 357 - 365