Comparison of cerebral oxygen saturation in premature infants by near-infrared spatially resolved spectroscopy: observations on probe-dependent bias

被引:19
|
作者
Sorensen, Line C. [1 ,2 ]
Leung, Terence S. [3 ]
Greisen, Gorm [2 ,4 ]
机构
[1] Copenhagen Univ Hosp, Dept Pediat & Neonatol, Hvidovre, Denmark
[2] Natl Univ Hosp, Rigshosp, Dept Neonatol, DK-2100 Copenhagen O, Denmark
[3] UCL, Dept Med Phys & Bioengn, London, England
[4] Univ Copenhagen, Fac Hlth Sci, Copenhagen, Denmark
基金
英国工程与自然科学研究理事会;
关键词
near-infrared spectrosopy (NIRS); spatially resolved spectroscopy (SRS); tissue oxygenation index (TOI); newborn; preterm;
D O I
10.1117/1.3013454
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Spatially resolved spectroscopy (SRS) allows the estimation of absolute tissue oxygen saturation, the ratio of oxygenated to total hemoglobin concentration, which may facilitate the comparison of results among patients. Eighty-two premature infants were included over two years. The cerebral tissue oxygenation index (c-TOI) was measured using NIRO 300 (Hamamatsu Photonics KK). c-TOI was measured at several positions in each infant. c-TOI varied over time, increasing in the first third and decreasing in the last third of the study period (p < 10(-6)). Two probes were used in the study, and a highly significant difference was found between these (p < 10(-6)). The mean difference was 8.5% (95% CI 5.4 to 11.6%). After correction for this difference, there was no variation over time. A conclusive explanation for the bias could not be identified. Since the study groups were well distributed, the bias had no influence on the results of our clinical study. We investigated an unexpected but highly significant probe-dependent bias in c-TOI with no conclusive explanation. Hence, comparisons of absolute TOI between groups of patients and among studies should be regarded with caution. A better strategy to detect potential instrumental problems will be useful in preventing biased c- TOI from occurring. (C) 2008 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3013454]
引用
收藏
页数:4
相关论文
共 50 条
  • [31] NEAR-INFRARED SPECTROSCOPY CEREBRAL AND SOMATIC (RENAL) OXYGEN SATURATION CORRELATION TO CONTINUOUS VENOUS OXYGEN SATURATION VIA INTRAVENOUS OXIMETRY CATHETER
    Marimon, Gilma
    Dockery, W.
    Sheridan, Michael
    Agarwal, Swati
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A102 - A102
  • [32] Effects of hyperventilation on cerebral oxygen saturation estimated using near-infrared spectroscopy: A randomised comparison between propofol and sevoflurane anaesthesia
    Ishiyama, Tadahiko
    Kotoda, Masakazu
    Asano, Nobumasa
    Ikemoto, Kodai
    Shintani, Noriyuki
    Matsuoka, Toru
    Matsukawa, Takashi
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2016, 33 (12) : 929 - 935
  • [33] Differences of cerebral oxygen saturation in dialysis patients: a comparison of three principals of near infrared spectroscopy
    Yasunori Yagi
    Yasunori Kubo
    Koji Hoshino
    Kazufumi Okada
    Kiyohiko Hotta
    Nobuo Shinohara
    Yuji Morimoto
    Journal of Anesthesia, 2023, 37 : 861 - 867
  • [34] Near-infrared spectroscopy cerebral and somatic (renal) oxygen saturation correlation to continuous venous oxygen saturation via intravenous oximetry catheter
    Marimon, Gilma A.
    Dockery, W. Keith
    Sheridan, Michael J.
    Agarwal, Swati
    JOURNAL OF CRITICAL CARE, 2012, 27 (03) : 314.e13 - 314.e18
  • [35] Correlation between cerebral oxygen saturation measured by near-infrared spectroscopy and jugular oxygen saturation in patients with severe closed head injury
    Ter Minassian, A
    Poirier, N
    Pierrot, M
    Menei, P
    Granry, JC
    Ursino, M
    Beydon, L
    ANESTHESIOLOGY, 1999, 91 (04) : 985 - 990
  • [36] Differences of cerebral oxygen saturation in dialysis patients: a comparison of three principals of near infrared spectroscopy
    Yagi, Yasunori
    Kubo, Yasunori
    Hoshino, Koji
    Okada, Kazufumi
    Hotta, Kiyohiko
    Shinohara, Nobuo
    Morimoto, Yuji
    JOURNAL OF ANESTHESIA, 2023, 37 (06) : 861 - 867
  • [37] Detecting cerebral hypoxia-ischemia of newborn piglets using spatially-resolved near-infrared spectroscopy
    Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
    不详
    Guang Pu Xue Yu Guang Pu Fen Xi, 2008, 10 (2263-2267):
  • [38] Detecting Cerebral Hypoxia-Ischemia of Newborn Piglets Using Spatially-Resolved Near-Infrared Spectroscopy
    Hou Xin-lin
    Teng Yi-chao
    Ding Hai-shu
    Ding Hai-yan
    Zhou Cong-le
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (10) : 2263 - 2267
  • [39] Measuring the tensile strain of wood by visible and near-infrared spatially resolved spectroscopy
    Ma, Te
    Inagaki, Tetsuya
    Yoshida, Masato
    Ichino, Mayumi
    Tsuchikawa, Satoru
    CELLULOSE, 2021, 28 (17) : 10787 - 10801
  • [40] Spatially resolved near-infrared excited Raman spectroscopy of nanocrystalline diamond films
    Veres, M.
    Toth, S.
    Kukovecz, A.
    Koos, M.
    DIAMOND AND RELATED MATERIALS, 2008, 17 (4-5) : 515 - 519