Evaluation of right and left ventricular function by quantitative blood-pool SPECT (QBS): Comparison with conventional methods and quantitative gated SPECT (QGS)

被引:10
|
作者
Odagiri, Keiichi
Wakabayashi, Yasushi
Tawarahara, Kei
Kurata, Chinori
Urushida, Tsuyoshi
Katoh, Hideki
Satoh, Hiroshi
Hayashi, Hideharu
机构
[1] Hamamatsu Univ Sch Med, Dept Internal Med 3, Div Cardiol, Hamamatsu, Shizuoka 4313192, Japan
[2] Hamamatsu Social Insurance Hosp, Dept Internal Med, Hamamatsu, Shizuoka, Japan
[3] Hamamatsu Red Cross Hosp, Dept Cardiol, Hamamatsu, Shizuoka, Japan
关键词
quantitative gated blood-pool SPECT (QBS); quantitative gated SPECT (QGS); Tc-99m-human serum albumin-DTPA; left ventricular ejection fraction; reproducibility;
D O I
10.1007/BF03026815
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Though quantitative ECG-gated blood-pool SPECT (QBS) has become a popular tool in research settings, more verification is necessary for its utilization in clinical medicine. To evaluate the reliability of the measurements of left and right ventricular functions with QBS, we performed QBS, as well as first-pass pool (FPP) and ECG-gated blood-pool (GBP) studies on planar images in 41 patients and 8 healthy volunteers. Quantitative ECG-gated myocardial perfusion SPECT (QGS) was also performed in 30 of 49 subjects. First, we assessed the reproducibility of the measurements of left and right ventricular ejection fraction (LVEF, RVEF) and left and right ventricular enddiastolic volume (LVEDV, RVEDV) with QBS. Second, LVEF and RVEF obtained from QBS were compared with those from FPP and GBP, respectively. Third, LVEF and LVEDV obtained from QBS were compared with those from QGS, respectively. The intra- and inter-observer reproducibilities were excellent for LVEF, LVEDV, RVEF and RVEDV measured with QBS (r = 0.88 to 0.96, p < 0.01), while the biases in the measurements of RVEF and RVEDV were relatively large. LVEF obtained from QBS correlated significantly with those from FPP and GBP, while RVEF from QBS did not. LVEF and LVEDV obtained from QBS were significantly correlated with those from QGS, but the regression lines were not close to the lines of identity. In conclusion, the measurements of LVEF and LVEDV with QBS have good reproducibility and are useful clinically, while those of RVEF and RVEDV are less useful compared with LVEF and LVEDV. The algorithm of QBS for the measurements of RVEF and RVEDV remains to be improved.
引用
收藏
页码:519 / 526
页数:8
相关论文
共 50 条
  • [31] Evaluation of Ventricular Function by Gated Blood Pool SPECT: A Simulation Study
    Mohseni, S.
    Bitarafan-Rajabi, A.
    Kamaliasl, A.
    Entezarmahdi, S. M.
    Shahpouri, Z.
    Segars, P.
    Bordbar, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S440 - S440
  • [32] Evaluation of right ventricular function by NuSMUGA software: gated blood-pool SPECT vs. first-pass radionuclide angiography
    R.H.J.A. Slart
    L. Poot
    D.A. Piers
    D.J. van Veldhuisen
    P.L. Jager
    The International Journal of Cardiovascular Imaging, 2003, 19 : 401 - 407
  • [33] Evaluation of right ventricular function by NuSMUGA software: gated blood-pool SPECT vs. first-pass radionuclide angiography
    Slart, RHJA
    Poot, L
    Piers, DA
    van Veldhuisen, DJ
    Jager, PL
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2003, 19 (05): : 401 - 407
  • [34] Repeatability of left and right ventricular function measured with egg-gated blood-pool spect versus planar radionuclide cardiac angiography.
    Daou, D
    Coaguila, C
    Helal, BO
    Fourme, T
    Carel, I
    Slama, M
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 137P - 138P
  • [35] Evaluation of left and right ventricular ejection fraction and volumes from gated blood-pool SPECT in patients with dilated cardiomyopathy comparison with cardiac magnetic resonance imaging
    Xie, Bo-Qia
    Tian, Yue-Qin
    Zhang, Jian
    Kang, Lian-Ming
    Zhao, Shi-Hua
    Lu, Min-Jie
    Yang, Min-Fu
    Wang, Dao-Yu
    Guo, Feng
    He, Zuo-Xiang
    CARDIOLOGY, 2011, 120 : 60 - 60
  • [36] Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT: Can we use the same reference database?
    Paul, AK
    Hasegawa, S
    Yoshioka, J
    Yamaguchi, H
    Tsujimura, E
    Nishimura, T
    ANNALS OF NUCLEAR MEDICINE, 2000, 14 (02) : 75 - 80
  • [37] SPECT versus planar gated blood pool imaging for left ventricular evaluation
    François Harel
    Vincent Finnerty
    Quam Ngo
    Jean Grégoire
    Paul Khairy
    Bernard Thibault
    Journal of Nuclear Cardiology, 2007, 14 : 544 - 549
  • [38] Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT: Can we use the same reference database?
    Asit Kf. Paul
    Shinji Hasegawa
    Jun Yoshioka
    Hitoshi Yamaguchi
    Eiichiro Tsujimura
    Tsunehiko Nishimura
    Annals of Nuclear Medicine, 2000, 14 : 75 - 80
  • [39] SPECT versus planar gated blood pool imaging for left ventricular evaluation
    Harel, Francois
    Finnerty, Vincent
    Ngo, Quam
    Gregoire, Jean
    Khairy, Paul
    Thibault, Bernard
    JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) : 544 - 549
  • [40] Evaluation of ventricular function (left and right) by Gated-Spect-Blood-Pool (GBPS):: description of the Technique and comparison with equilibrium radionuclide ventriculography (ERV).
    Paredes-Rodriguez, P.
    Castro-Beiras, J.
    Orduna-Diez, M.
    Vera-Schmuelling, U.
    Crespo-Diez, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S282 - S283