Experimental and numerical study of a duct/heat exchanger unit for building ventilation

被引:23
|
作者
Manz, H [1 ]
Huber, H
机构
[1] Swiss Fed Labs Mat Testing & Res EMPA, CH-8600 Dubendorf, Switzerland
[2] Univ Appl Sci, Lucerne Sch Engn & Architecture HTA, CH-6048 Horw, Switzerland
关键词
residential ventilation; heat exchanger; duct; temperature efficiency;
D O I
10.1016/S0378-7788(00)00043-8
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A mechanical building ventilation unit is presented that unites two functions: fluid transport and heat recovery. Aluminum fins in the supply air duct and in the adjacent extract air duct increase the heat flow from fluid to fluid. This unit is intended to be used mainly for residential ventilation and was investigated by means of experiments and simulations. Airflow rates, temperatures, air humidities and pressure differences were measured on a prototype device in an experimental set-up. Additionally, using a computer program for two-dimensional heat conduction analysis and a simple analytical model, the efficiency of heat recovery was calculated and compared with measurements. Afterwards, the influence of variations of the heat exchanger geometry on thermal efficiency was investigated by means of simulations. It was shown that using this concept it is possible to realize a ventilation unit with high-efficiency heat exchange, e.g. temperature efficiency of 0.7 at a duct length of 6 m. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:189 / 196
页数:8
相关论文
共 50 条
  • [21] An Experimental and Numerical Investigation of a Heat Exchanger for Showers
    Maciorowski, Damian
    Spychala, Maciej Jan
    Miedzinska, Danuta
    ENERGIES, 2024, 17 (15)
  • [22] Numerical optimization and experimental testing of a new low pressure heat exchanger (LoPHEx) for passive ventilation of buildings
    Simonetti, Marco
    Fracastoro, Gian Vincenzo
    Chiesa, Giacomo
    Sola, Stefano
    APPLIED THERMAL ENGINEERING, 2016, 103 : 720 - 729
  • [23] Experimental study of an earth to air heat exchanger used by an energy efficient building
    Iordache, Gabriela-Elena
    Ionescu, Constantin
    Necula, Horia
    2019 54TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2019,
  • [24] Impacts of Double V-Rings in the Heat Exchanger Duct on Heat Transfer and Flow Behaviors: A Numerical Study
    Boonloi, Amnart
    Jedsadaratanachai, Withada
    Jedsadaratanachai, Withada (withada.je@kmitl.ac.th), 1600, Hindawi Limited (2021):
  • [25] Impacts of Double V-Rings in the Heat Exchanger Duct on Heat Transfer and Flow Behaviors: A Numerical Study
    Boonloi, Amnart
    Jedsadaratanachai, Withada
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2021, 2021
  • [26] Numerical Investigation of Thermohydraulics Performance in Elliptical Twisted Duct Heat Exchanger
    Bhattacharyya, Suvanjan
    Chattopadhyay, Himadri
    Pal, Tarun Kanti
    Roy, Anirban
    CAD/CAM, ROBOTICS AND FACTORIES OF THE FUTURE, 2016, : 839 - 849
  • [27] Inhibition of corrosion in amine air cooled heat exchanger: Experimental and numerical study
    Valeh-e-Sheyda, Peyvand
    Rashidi, Hamed
    APPLIED THERMAL ENGINEERING, 2016, 98 : 1241 - 1250
  • [28] Experimental and numerical study of a tube-fin cool storage heat exchanger
    Li, Da
    Yang, Chunxin
    Yang, Han
    APPLIED THERMAL ENGINEERING, 2019, 149 : 712 - 722
  • [29] Numerical and experimental study on liquid lithium-air heat exchanger design
    Wang, Lizhi
    Zhang, Xueqin
    Wu, Tao
    Rong, Yi
    Ye, Zongbiao
    Li, Xiankai
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 158
  • [30] Experimental and Numerical Study of an Earth-to-Air Heat Exchanger in Northeastern Poland
    Skotnicka-Siepsiak, Aldona
    Wesolowski, Maciej
    Piechocki, Janusz
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2018, 27 (03): : 1255 - 1260