Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft: A biomechanical analysis

被引:161
|
作者
Milano, G
Mulas, PD
Ziranu, F
Piras, S
Manunta, A
Fabbriciani, C
机构
[1] Univ Sacred Heart, Dept Orthopaed, I-00168 Rome, RM, Italy
[2] Dept Orthopaed, Sassari, Italy
关键词
anterior cruciate ligament; hamstring; graft; biomechanics femur; fixation;
D O I
10.1016/j.arthro.2006.04.082
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The aim of the present study was to compare the mechanical behavior of some devices used for femoral fixation of doubled hamstring tendon graft in anterior cruciate ligament (ACL) reconstruction when included in a graft fixation complex (GFC). Methods: An ACL reconstruction was performed on 90 porcine knees. The graft used was the doubled lateral extensor of toes (DLET). Nine different femoral fixation devices were tested and classified according to their fixation mechanism: compression (Bioscrew and RCI screw); expansion (Rigidfix); cortical suspension (Ligament Anchor, EndoButton-CL, and Swing Bridge); cancellous suspension (Linx-HT); and cortical-cancellous suspension (Transfix and Bio-Transfix). All GFC were subjected to a cyclic loading test, then to a load-to-failure test. Graft elongation after 1,000 load cycles, failure load, and stiffness were calculated for each device. Results: Regarding graft elongation, Bioscrew and RCI screws showed the highest mean values. All the other GFC showed no significant differences between them when 8 elongation (elongation (1,000 cycles) - elongation (20 cycles)) was considered. For failure load, the highest mean values were observed-for Bio-Transfix, Transfix, and Swing Bridge; a homogeneous subset with the lowest mean values was formed by Ligament Anchor, RCI screw, Bioscrew, and Linx-HT. For stiffness, the greatest values were observed for Bio-Transfix, Transfix, and Swing Bridge; all other groups showed no significant differences between them. Conclusions: Cortical-cancellous suspension fixation seemed to offer the best and most predictable results in terms of elongation, fixation strength, and stiffness. For both compression and suspension, the weakest fixation was attained with cancellous fixation devices. Cortical suspension devices showed a greatly variable mechanical behavior, according to their design. Clinical Relevance: Transcondylar devices offer the best structural properties for femoral fixation of doubled hamstring tendon graft in ACL reconstruction.
引用
收藏
页码:660 / 668
页数:9
相关论文
共 50 条
  • [31] A survey of the tension applied to a doubled hamstring tendon graft for reconstruction of the anterior cruciate ligament
    Cunningham, R
    West, JR
    Greis, PE
    Burks, RT
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (09): : 983 - 988
  • [32] Effect of Time on MRI Appearance of Graft After ACL Reconstruction: A Comparison of Autologous Hamstring and Quadriceps Tendon Grafts
    Panos, Joseph A.
    Devitt, Brian M.
    Feller, Julian A.
    Klemm, Haydn J.
    Hewett, Timothy E.
    Webster, Kate E.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (09)
  • [33] Comparison of Functional Outcomes of an Anterior Cruciate Ligament (ACL) Reconstruction Using a Peroneus Longus Graft as an Alternative to the Hamstring Tendon Graft
    Agarwal, Abhishek
    Singh, Shitanshu
    Singh, Arpit
    Tewari, Prakash
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (04)
  • [34] Interference screw fixation of doubled flexor tendon graft in anterior cruciate ligament reconstruction - biomechanical evaluation with cyclic elongation
    Nakano, H
    Yasuda, K
    Tohyama, H
    Yamanaka, M
    Wada, T
    Kaneda, K
    CLINICAL BIOMECHANICS, 2000, 15 (03) : 188 - 195
  • [35] Analysis of biomechanical properties of patellar ligament graft and quadruple hamstring tendon graft
    Biuk, Egon
    Zelic, Zoran
    Rapan, Sasa
    Curic, Goran
    Biuk, Dubravka
    Radic, Radivoje
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S14 - S17
  • [36] The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction -: Part II:: Tibial site
    Kousa, P
    Järvinen, TLN
    Vihavainen, M
    Kannus, P
    Järvinen, M
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (02): : 182 - 188
  • [37] Significant anterior enlargement of femoral tunnel aperture after hamstring ACL reconstruction, compared to bone–patellar tendon–bone graft
    Hiroshi Amano
    Yoshinari Tanaka
    Keisuke Kita
    Ryohei Uchida
    Yuta Tachibana
    Yasukazu Yonetani
    Tatsuo Mae
    Yoshiki Shiozaki
    Shuji Horibe
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 461 - 470
  • [38] Introduction of a new fixation method for free tendon fixation in ACL-Reconstruction - A biomechanical study
    von der Heide, N.
    Ebneter, L.
    Behrend, H.
    Stutz, G.
    Kuster, M.
    SWISS MEDICAL WEEKLY, 2010, 140 (23-24) : 9S - 9S
  • [39] The effects of two different fixation methods on femoral bone tunnel enlargement and clinical results in anterior cruciate ligament reconstruction with hamstring tendon graft
    Cinar, Bekir Murat
    Akpinar, Sercan
    Hersekli, Murat Ali
    Uysal, Mustafa
    Cesur, Necip
    Pourbagher, Aysin
    Derincek, Alihan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (06) : 515 - 521
  • [40] Hamstring graft tibial fixation: biomechanical properties of different linkage systems
    Alberto Gobbi
    Sanjeev Mahajan
    Benjamin Tuy
    Ian Panuncialman
    Knee Surgery, Sports Traumatology, Arthroscopy, 2002, 10 : 330 - 334