Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft: A biomechanical analysis

被引:161
|
作者
Milano, G
Mulas, PD
Ziranu, F
Piras, S
Manunta, A
Fabbriciani, C
机构
[1] Univ Sacred Heart, Dept Orthopaed, I-00168 Rome, RM, Italy
[2] Dept Orthopaed, Sassari, Italy
关键词
anterior cruciate ligament; hamstring; graft; biomechanics femur; fixation;
D O I
10.1016/j.arthro.2006.04.082
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The aim of the present study was to compare the mechanical behavior of some devices used for femoral fixation of doubled hamstring tendon graft in anterior cruciate ligament (ACL) reconstruction when included in a graft fixation complex (GFC). Methods: An ACL reconstruction was performed on 90 porcine knees. The graft used was the doubled lateral extensor of toes (DLET). Nine different femoral fixation devices were tested and classified according to their fixation mechanism: compression (Bioscrew and RCI screw); expansion (Rigidfix); cortical suspension (Ligament Anchor, EndoButton-CL, and Swing Bridge); cancellous suspension (Linx-HT); and cortical-cancellous suspension (Transfix and Bio-Transfix). All GFC were subjected to a cyclic loading test, then to a load-to-failure test. Graft elongation after 1,000 load cycles, failure load, and stiffness were calculated for each device. Results: Regarding graft elongation, Bioscrew and RCI screws showed the highest mean values. All the other GFC showed no significant differences between them when 8 elongation (elongation (1,000 cycles) - elongation (20 cycles)) was considered. For failure load, the highest mean values were observed-for Bio-Transfix, Transfix, and Swing Bridge; a homogeneous subset with the lowest mean values was formed by Ligament Anchor, RCI screw, Bioscrew, and Linx-HT. For stiffness, the greatest values were observed for Bio-Transfix, Transfix, and Swing Bridge; all other groups showed no significant differences between them. Conclusions: Cortical-cancellous suspension fixation seemed to offer the best and most predictable results in terms of elongation, fixation strength, and stiffness. For both compression and suspension, the weakest fixation was attained with cancellous fixation devices. Cortical suspension devices showed a greatly variable mechanical behavior, according to their design. Clinical Relevance: Transcondylar devices offer the best structural properties for femoral fixation of doubled hamstring tendon graft in ACL reconstruction.
引用
收藏
页码:660 / 668
页数:9
相关论文
共 50 条
  • [1] Mechanical comparison of biodegradable femoral fixation devices for hamstring tendon graft - A biomechanical study in a porcine model
    Wu, Jia-Lin
    Yeh, Tsu-Te
    Shen, Hsain-Chung
    Cheng, Cheng-Kung
    Lee, Chian-Her
    CLINICAL BIOMECHANICS, 2009, 24 (05) : 435 - 440
  • [2] The Bone Bridge for Tibial ACL Graft Fixation: A Biomechanical Analysis of Different Tibial Fixation Methods for ACL Reconstruction
    Peez, Christian
    Gressmann, Marvin
    Raschke, Michael J.
    Glasbrenner, Johannes
    Briese, Thorben
    Frank, Andre
    Herbst, Elmar
    Kittl, Christoph
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (01)
  • [3] Hamstring tendons or patellar tendon as graft for ACL reconstruction?
    Eriksson, Ejnar
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (02) : 113 - 114
  • [4] Hamstring tendons or patellar tendon as graft for ACL reconstruction?
    Ejnar Eriksson
    Knee Surgery, Sports Traumatology, Arthroscopy, 2007, 15 : 113 - 114
  • [5] The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction -: Part I:: Femoral site
    Kousa, P
    Järvinen, TLN
    Vihavainen, M
    Kannus, P
    Järvinen, M
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (02): : 174 - 181
  • [6] Biomechanical Considerations for Graft Fixation in ACL Reconstruction
    Ettinger, Max
    Petri, Max
    Kwisda, Sebastian
    Krettek, Christian
    Jagodzinski, Michael
    TECHNIQUES IN ORTHOPAEDICS, 2013, 28 (02) : 126 - 132
  • [7] Prospective randomized clinical comparison of femoral transfixation versus bioscrew fixation in hamstring tendon ACL reconstruction - a preliminary report
    Rose, Tim
    Hepp, Pierre
    Venus, Julia
    Stockmar, Christoph
    Josten, Christoph
    Lill, Helmut
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (08) : 730 - 738
  • [8] Prospective randomized clinical comparison of femoral transfixation versus bioscrew fixation in hamstring tendon ACL reconstruction—a preliminary report
    Tim Rose
    Pierre Hepp
    Julia Venus
    Christoph Stockmar
    Christoph Josten
    Helmut Lill
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 730 - 738
  • [10] Reimagined MPFL Reconstruction: Retinacular Fixation of the Doubled Hamstring Graft at the Patella and Suture Anchor-Based Femoral Fixation
    Nazeer, Muhammed Ehsan
    Goel, Sagar
    Nazeer, Muhammed
    Sreenivasan, Gowrishankar
    Muhammed, Mohsin Nazeer
    Shajil, Suzaan
    ADVANCES IN ORTHOPEDICS, 2023, 2023