Analysis of 3D Prints by X-ray Computed Microtomography and Terahertz Pulsed Imaging

被引:64
|
作者
Markl, Daniel [1 ]
Zeitler, J. Axel [1 ]
Rasch, Cecilie [2 ]
Michaelsen, Maria Hotoft [2 ]
Mullertz, Anette [2 ]
Rantanen, Jukka [2 ]
Rades, Thomas [2 ]
Botker, Johan [2 ]
机构
[1] Univ Cambridge, Dept Chem Engn & Biotechnol, Philippa Fawcett Dr, Cambridge CB3 0AS, England
[2] Univ Copenhagen, Dept Pharm, Univ Pk 2, DK-2100 Copenhagen, Denmark
基金
英国工程与自然科学研究理事会;
关键词
3D printing; microstructure; polyvinyl alcohol (PVA); terahertz pulsed imaging (TPI); X-ray computed microtomography (X mu CT); ORAL DOSAGE FORMS; DRUG-RELEASE; TOMOGRAPHY; DEPOSITION; CT;
D O I
10.1007/s11095-016-2083-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose A 3D printer was used to realise compartmental dosage forms containing multiple active pharmaceutical ingredient (API) formulations. This work demonstrates the microstructural characterisation of 3D printed solid dosage forms using X-ray computed microtomography (X mu CT) and terahertz pulsed imaging (TPI). Methods Printing was performed with either polyvinyl alcohol (PVA) or polylactic acid (PLA). The structures were examined by X mu CT and TPI. Liquid self-nanoemulsifying drug delivery system (SNEDDS) formulations containing saquinavir and halofantrine were incorporated into the 3D printed compartmentalised structures and in vitro drug release determined. Results A clear difference in terms of pore structure between PVA and PLA prints was observed by extracting the porosity (5.5% for PVA and 0.2% for PLA prints), pore length and pore volume from the X mu CT data. The print resolution and accuracy was characterised by X mu CT and TPI on the basis of the computer-aided design (CAD) models of the dosage form (compartmentalised PVA structures were 7.5 +/- 0.75% larger than designed; n = 3). Conclusions The 3D printer can reproduce specific structures very accurately, whereas the 3D prints can deviate from the designed model. The microstructural information extracted by X mu CT and TPI will assist to gain a better understanding about the performance of 3D printed dosage forms.
引用
收藏
页码:1037 / 1052
页数:16
相关论文
共 50 条
  • [31] 3D-Quantitative Morphometrics in Craniofacial Development by X-ray Computed Microtomography
    Zikmund, T.
    Tesarova, M.
    Buchtova, M.
    Kavkova, M.
    Hampl, M.
    Hruba, E.
    Kaucka, M.
    Adameyko, I
    Kaiser, J.
    JOURNAL OF MORPHOLOGY, 2019, 280 : S243 - S244
  • [32] The 3D microscopic 'signature' of strain within glacial sediments revealed using X-ray computed microtomography
    Tarplee, Mark F. V.
    van der Meer, Jaap J. M.
    Davis, Graham R.
    QUATERNARY SCIENCE REVIEWS, 2011, 30 (23-24) : 3501 - 3532
  • [33] 3D IMAGING OF THE SOLID PHASE OF POROUS BAKERY PRODUCTS USING SYNCHROTRON X-RAY MICROTOMOGRAPHY
    van Dalen, Gerard
    Nootenboom, Peter
    Don, Aat
    den Adel, Ruud
    Roijers, Eli
    ECS10: THE10TH EUROPEAN CONGRESS OF STEREOLOGY AND IMAGE ANALYSIS, 2009, : 335 - 341
  • [34] APPLICATIONS OF X-RAY RADIOGRAPHY AND X-RAY COMPUTED MICROTOMOGRAPHY IN GEMOLOGY
    Zhou, Chunhui
    Towbin, W. Henry
    GEMS & GEMOLOGY, 2024, 60 (04):
  • [35] 3D Quantitative Analysis of Graphite Morphology in Ductile Cast Iron by X-ray Microtomography
    Yin, Yajun
    Tu, Zhixin
    Zhou, Jianxin
    Zhang, Dongqiao
    Wang, Min
    Guo, Zhao
    Liu, Changchang
    Chen, Xiang
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2017, 48A (08): : 3794 - 3803
  • [36] Synchrotron X-ray microtomography and 3D image analysis of medium density fiberboard (MDF)
    Walther, Thomas
    Thoemen, Heiko
    HOLZFORSCHUNG, 2009, 63 (05) : 581 - 587
  • [37] 3D Quantitative Analysis of Graphite Morphology in Ductile Cast Iron by X-ray Microtomography
    Yajun Yin
    Zhixin Tu
    Jianxin Zhou
    Dongqiao Zhang
    Min Wang
    Zhao Guo
    Changchang Liu
    Xiang Chen
    Metallurgical and Materials Transactions A, 2017, 48 : 3794 - 3803
  • [38] Geoscience applications of x-ray computed microtomography
    Rivers, ML
    Sutton, SR
    Eng, P
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 78 - 86
  • [39] X-ray computed microtomography of Megachirella wachtleri
    Tiago R. Simões
    Michael W. Caldwell
    Mateusz Tałanda
    Massimo Bernardi
    Alessandro Palci
    Oksana Vernygora
    Federico Bernardini
    Lucia Mancini
    Randall L. Nydam
    Scientific Data, 5
  • [40] X-ray computed microtomography of Megachirella wachtleri
    Simoes, Tiago R.
    Caldwell, Michael W.
    Talanda, Mateusz
    Bernardi, Massimo
    Palci, Alessandro
    Vernygora, Oksana
    Bernardini, Federico
    Mancini, Lucia
    Nydam, Randall L.
    SCIENTIFIC DATA, 2018, 5