Status of the endcap BGO calorimeter of the CMD-3 detector

被引:13
|
作者
Akhmetshin, R. R. [1 ]
Grigoriev, D. N. [1 ]
Kazanin, V. F. [1 ]
Tsaregorodtsev, S. M. [1 ]
Yudin, Yu. V. [1 ]
机构
[1] Russian Acad Sci, Budker Inst Nucl Phys, Siberian Div, Novosibirsk 630090, Russia
基金
俄罗斯基础研究基金会;
关键词
29.40.Mc; 29.40.Vj;
D O I
10.1134/S1063778809030119
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The electromagnetic endcap BGO calorimeter of the CMD-3 detector is ready for experiments at the new e (+) e (-) collider VEPP-2000. Light readout is performed by silicon photodiodes. A thermalcontrol system that is able to maintain the calorimeter temperature at a level of 12 +/- 1A degrees C was designed and manufactured. All blocks of the endcap calorimeter are assembled, tested, and prepared for installing at the detector.
引用
收藏
页码:477 / 481
页数:5
相关论文
共 50 条
  • [11] Performance of the BGO endcap calorimeter with phototriode readout for the CMD-2 detector
    Grigoriev, D.N.
    Akhmetshin, R.R.
    Beschastnov, P.M.
    Fedorenko, V.E.
    Pyata, E.E.
    Smakhtin, V.P.
    Yudin, Yu.V.
    Shlegel, V.N.
    Vasiliev, Ya.V.
    IEEE Transactions on Nuclear Science, 1995, 42 (4 pt 1): : 505 - 509
  • [12] PERFORMANCE OF THE BGO ENDCAP CALORIMETER WITH PHOTOTRIODE READOUT FOR THE CMD-2 DETECTOR
    GRIGORIEV, DN
    AKHMETSHIN, RR
    BESCHASTNOV, PM
    FEDORENKO, VE
    PYATA, EE
    SMAKHTIN, VP
    YUDIN, YV
    SHLEGEL, VN
    VASILIEV, YV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 505 - 509
  • [13] Liquid xenon calorimeter for a CMD-3 detector
    Anisyonkov, A. V.
    Barkov, L. M.
    Bashtovoy, N. S.
    Grebenuk, A. A.
    Khazin, B. I.
    Kravchenko, E. V.
    Pestov, Yu. N.
    Priymenko, L. A.
    Stepanov, P. Yu.
    Zverev, S. G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 266 - 267
  • [14] Testing and calibration of the BGO endcap calorimeter with phototriode readout for the CMD-2 detector
    Akhmetshin, RR
    Grigoriev, DN
    Kazanin, VF
    Logashenko, IB
    Smakhtin, VP
    Yudin, YV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 379 (03): : 509 - 510
  • [15] Energy calibration of the barrel calorimeter of the CMD-3 detector
    Anisenkov, A. V.
    Aulchenko, V. M.
    Bashtovoy, N. S.
    Bondar, A. E.
    Grebenuk, A. A.
    Epifanov, D. A.
    Epshteyn, L. B.
    Erofeev, A. L.
    Kovalenko, O. A.
    Kozyrev, A. N.
    Kuzmin, A. S.
    Mikhailov, K. Yu.
    Logashenko, I. B.
    Razuvaev, G. P.
    Ruban, A. A.
    Shebalin, V. E.
    Shwartz, B. A.
    Talyshev, A. A.
    Titov, V. M.
    Yudin, Yu. V.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [16] Charged particle identification with the liquid Xenon calorimeter of the CMD-3 detector
    Ivanov, V. L.
    Fedotovich, G. V.
    Anisenkov, A. V.
    Grebenuk, A. A.
    Mikhailov, K. Yu.
    Kozyrev, A. A.
    Shebalin, V. E.
    Ruban, A. A.
    Bashtovoy, N. S.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [17] Charged particle identification with the liquid xenon calorimeter of the CMD-3 detector
    Ivanov, V. L.
    Fedotovich, G., V
    Akhmetshin, R. R.
    Amirkhanov, A. N.
    Anisenkov, A., V
    Aulchenko, V. M.
    Bashtovoy, N. S.
    Bondar, A. E.
    Bragin, A., V
    Eidelman, S., I
    Epifanov, D. A.
    Epshteyn, L. B.
    Erofeev, A. L.
    Gayazov, S. E.
    Grebenuk, A. A.
    Gribanov, S. S.
    Grigoriev, D. N.
    Ignatov, F., V
    Karpov, S., V
    Kazanin, V. F.
    Korobov, A. A.
    Kozyrev, A. N.
    Kozyrev, E. A.
    Krokovny, P. P.
    Kuzmenko, A. E.
    Kuzmin, A. S.
    Logashenko, I. B.
    Lukin, P. A.
    Mikhailov, K. Yu
    Okhapkin, V. S.
    Pestov, Yu N.
    Popov, A. S.
    Razuvaev, G. P.
    Ruban, A. A.
    Ryskulov, N. M.
    Ryzhenenkov, A. E.
    Semenov, A., V
    Shebalin, V. E.
    Shemyakin, D. N.
    Shwartz, B. A.
    Solodov, E. P.
    Titov, V. M.
    Talyshev, A. A.
    Tolmachev, S. S.
    Uskov, A. A.
    Vorobiov, A., I
    Yudin, Yu, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1015
  • [18] Signal processing in the calorimeter pre-trigger of the CMD-3 detector
    Kozyrev, A. N.
    Ruban, A. A.
    Yudin, Yu. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 345 - 348
  • [19] Signal processing module for the liquid xenon calorimeter of CMD-3 detector
    Kakhuta, K. I.
    Yudin, Yu. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 342 - 344
  • [20] Combined Liquid Xenon and crystal CsI calorimeter of the CMD-3 detector
    Shebalin, V. E.
    Anisenkov, A. V.
    Bashtovoy, N. S.
    Epifanov, D. A.
    Erofeev, A. L.
    Grebenuk, A. A.
    Karpov, S. V.
    Khazin, B. I.
    Kovalenko, O. A.
    Kozyrev, A. N.
    Kuzmin, A. S.
    Mikhailov, K. Yu.
    Razuvaev, G. P.
    Ruban, A. A.
    Shwartz, B. A.
    Titov, V. M.
    Talyshev, A. A.
    Yudin, Yu. V.
    JOURNAL OF INSTRUMENTATION, 2014, 9