Micromachined array tip for multifocus fiber-based optical coherence tomography

被引:44
|
作者
Yang, VXD [1 ]
Munce, N
Pekar, J
Gordon, ML
Lo, S
Marcon, NE
Wilson, BC
Vitkin, IA
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
[2] St Michaels Hosp, Div Gastroenterol, Toronto, ON M5B 1W8, Canada
关键词
D O I
10.1364/OL.29.001754
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
High-resolution optical coherence tomography demands a large detector bandwidth and a high numerical aperture for real-time imaging, which is difficult to achieve over a large imaging depth. To resolve these conflicting requirements we propose a novel multifocus fiber-based optical coherence tomography system with a micromachined array tip. We demonstrate the fabrication of a prototype four-channel tip that maintains a 9-14-mum spot diameter with more than 500 mum of imaging depth. Images of a resolution target and a human tooth were obtained with this tip by use of a four-channel cascaded Michelson fiber-optic interferometer, scanned simultaneously at 8 kHz with geometric power distribution across the four channels. (C) 2004 Optical Society of America.
引用
收藏
页码:1754 / 1756
页数:3
相关论文
共 50 条
  • [21] Fiber-based polarization sensitive spectral domain optical coherence tomography using a fiber optic spectral polarimetry instrument
    Kim, E
    Milner, TE
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 283 - 291
  • [22] Fiber motion-insensitive fiber-based polarization-sensitive optical coherence tomography for optic axis determination
    Lu, Zenghai
    Liu, Cheng
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2020, 37 (03) : 608 - 617
  • [23] Simultaneous intensity, birefringence, and flow measurements with high-speed fiber-based optical coherence tomography
    Pierce, MC
    Park, BH
    Cense, B
    de Boer, JF
    OPTICS LETTERS, 2002, 27 (17) : 1534 - 1536
  • [24] Characterization of the polarization properties of biological tissues with fiber-based Mueller-matrix optical coherence tomography
    Jiao, SL
    Hsieh, TM
    Ai, J
    Todorovic, M
    LASER INTERACTION WITH TISSUE AND CELLS XV, 2004, 5319 : 130 - 134
  • [25] Polarization management to mitigate misalignment-induced fringe fading in fiber-based optical coherence tomography
    Wang, Nanshuo
    Liu, Xinyu
    Xiong, Qiaozhou
    Xie, Jun
    Chen, Shi
    Liu, Linbo
    OPTICS LETTERS, 2017, 42 (15) : 2996 - 2999
  • [26] Towards real time assessment of intramuscular fat content in meat using optical fiber-based optical coherence tomography
    Thampi, Abi
    Hitchman, Sam
    Coen, Stephane
    Vanholsbeeck, Frederique
    MEAT SCIENCE, 2021, 181
  • [27] Optical Coherence Tomography with a multi-fiber array in sample arm
    Nakaji, Haruo
    OPTICAL FIBER TECHNOLOGY, 2010, 16 (06) : 476 - 479
  • [28] All-fiber probe for optical coherence tomography with an extended depth of focus by a high-efficient fiber-based filter
    Qiu, Jianrong
    Shen, Yi
    Shangguan, Ziwei
    Bao, Wen
    Yang, Shanshan
    Li, Peng
    Ding, Zhihua
    OPTICS COMMUNICATIONS, 2018, 413 : 276 - 282
  • [29] Fast simulation and design of the fiber probe with a fiber-based pupil filter for optical coherence tomography using the eigenmode expansion approach
    Qiu, Jianrong
    Meng, Jia
    Liu, Zhiyi
    Han, Tao
    Ding, Zhihua
    OPTICS EXPRESS, 2021, 29 (02) : 2172 - 2183
  • [30] Optical-fiber-based Mueller optical coherence tomography
    Jiao, SL
    Yu, WR
    Stoica, G
    Wang, LHV
    OPTICS LETTERS, 2003, 28 (14) : 1206 - 1208