Efficacy and safety of transcatheter valve-in-valve replacement for Mitroflow bioprosthetic valve dysfunction

被引:9
|
作者
Mosquera, Victor X. [1 ]
Gonzalez-Barbeito, Miguel [1 ]
Bouzas-Mosquera, Alberto [2 ]
Herrera-Norena, Jose M. [1 ]
Velasco, Carlos [1 ]
Salgado-Fernandez, Jorge [2 ]
Calvino-Santos, Ramon [2 ]
Vazquez-Gonzalez, Nicolas [2 ]
Vazquez-Rodriguez, Jose M. [2 ]
Cuenca-Castillo, Jose J. [1 ]
机构
[1] Complejo Hosp Univ A Coruna, Dept Cardiac Surg, Xubias 84, La Coruna 15006, Spain
[2] Complejo Hosp Univ A Coruna, Dept Cardiol, La Coruna, Spain
关键词
aortic pericardial bioprosthesis; complication; structural valve deterioration; surgery; transcatheter aortic valve replacement; valve-in-valve; AORTIC BIOPROSTHESIS; DEGENERATED MITROFLOW; IMPLANTATION; OUTCOMES;
D O I
10.1111/jocs.13720
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesBioprostheses with pericardial leaflets mounted externally on the stent pose a high risk for valve-in-valve (ViV) procedures. This study analyzed the efficacy and safety of ViV procedures for treating structural valve deterioration (SVD) in Mitroflow bioprostheses. MethodsBetween January 2012 and August 2017, 11 patients (mean age 80.35.6 years) were treated for SVD of Mitroflow bioprostheses with transcatheter ViV procedures (six transapical [TA] and five transfemoral [TF]) using balloon expandable bioprostheses. ResultsAll patients but one were in NYHA class III-IV. Mean STS PROM, euroSCORE I, and euroSCORE II were 8 +/- 6.5%, 27.8 +/- 11.5%, and 12 +/- 5.9%, respectively. Two patients had a porcelain aorta. The size of implanted valves were 23mm in 10 cases and 26mm in one case. One patient suffered a coronary occlusion during a TF approach. The mean volume of contrast used in TF implants was 163 +/- 69.8mL. No contrast media were used in TA procedures. There was one in-hospital death (10%). At 1 year of follow-up, peak and mean aortic gradients were 25.5 +/- 5.8mmHg and 15.5 +/- 5.7mmHg, respectively. One patient had mild paravalvular regurgitation. Cumulative survival was 90.9% at 1 year, 70.7% at 2 years, and 53% at 3 years. ConclusionsViV procedures with balloon-expandable aortic valves provide good hemodynamic and clinical mid-term results for treating patients with a degenerated Mitroflow aortic bioprosthesis. Special care must be taken in small aortic roots, when the stented valve is in the supra-annular position to avoid coronary ostial obstruction.
引用
收藏
页码:356 / 362
页数:7
相关论文
共 50 条
  • [41] Valve-in-Valve Transcatheter Aortic Valve Replacement and Bioprosthetic Valve Fracture Comparing Different Transcatheter Heart Valve Designs An Ex Vivo Bench Study
    Sathananthan, Janarthanan
    Sellers, Stephanie
    Barlow, Aaron M.
    Stanova, Viktoria
    Fraser, Rob
    Toggweiler, Stefan
    Allen, Keith B.
    Chhatriwalla, Adnan
    Murdoch, Dale J.
    Hensey, Mark
    Lau, Karen
    Alkhodair, Abdullah
    Dvir, Danny
    Asgar, Anita W.
    Cheung, Anson
    Blanke, Philipp
    Ye, Jian
    Rieu, Regis
    Pibarot, Phillippe
    Wood, David
    Leipsic, Jonathan
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (01) : 65 - 75
  • [42] Outcomes of valve-in-valve transcatheter aortic valve implantation with and without bioprosthetic valve fracture
    Brinkmann, Christina
    Abdel-Wahab, Mohamed
    Bedogni, Francesco
    Bhadra, Oliver Daniel
    Charbonnier, Gaetan
    Conradi, Lenard
    Hildick-Smith, David
    Kargoli, Faraj
    Latib, Azeem
    Van Mieghem, Nicolas M.
    Mylotte, Darren
    Landes, Uri
    Pilgrim, Thomas
    Stripling, Jan
    Taramasso, Maurizio
    Tchetche, Didier
    Testa, Luca
    Thiele, Holger
    Webb, John
    Windecker, Stephan
    Witt, Julian
    Wohlmuth, Peter
    Schofer, Joachim
    EUROINTERVENTION, 2021, 17 (10) : 848 - 855
  • [43] Simultaneous transcatheter tricuspid and mitral valve-in-valve replacement for the treatment of degenerated bioprosthetic valves
    Kanjanahattakij, Napatt
    Tuluca, Alexandra
    Pressman, Gregg S.
    Singer, Raymond
    Witzke, Christian
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (07) : 2182 - 2186
  • [44] Simultaneous transcatheter valve-in-valve replacement of severely degenerated bioprosthetic aortic and mitral prostheses
    Wienemann, Hendrik
    Mauri, Victor
    Kuhn, Elmar
    Baldus, Stephan
    Adam, Matti
    CLINICAL RESEARCH IN CARDIOLOGY, 2022, 111 (12) : 1396 - 1400
  • [45] Simultaneous transcatheter valve-in-valve replacement of severely degenerated bioprosthetic aortic and mitral prostheses
    Hendrik Wienemann
    Victor Mauri
    Elmar Kuhn
    Stephan Baldus
    Matti Adam
    Clinical Research in Cardiology, 2022, 111 : 1396 - 1400
  • [46] Transcatheter valve-in-valve implantation in a degenerated very small Mitroflow prosthesis
    Lopez, Stephane
    Meyer, Pierre
    Teboul, Jacques
    Deharo, Pierre
    Mihoubi, Alain
    Elbeze, Jean Pierre
    Lena, Diane
    Camarasa, Philippe
    Laborde, Jean Claude
    Drogoul, Laurent
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2018, 27 (06) : 850 - 855
  • [47] Valve-in-valve transcatheter aortic valve implantation overcoming hostile anatomy: Evolut R for the treatment of Mitroflow bioprosthesis dysfunction
    Ruparelia N.
    Colombo A.
    Latib A.
    Cardiovascular Intervention and Therapeutics, 2016, 31 (4) : 292 - 295
  • [48] Reoperative "valve-in-valve" transapical transcatheter mitral valve replacement in a high-risk patient with a recent transapical transcatheter aortic valve replacement and a degenerated bioprosthetic mitral valve
    de Biasi, Andreas R.
    Wong, Shing-Chiu
    Salemi, Arash
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (05): : E209 - E210
  • [49] Redo Mitral Valve Replacement After Valve-in-Valve Transcatheter Mitral Valve Replacement
    Tsukioka, Yusuke
    Jeevanandam, Valluvan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [50] When Device Failure Translates to Therapeutic Efficacy Intentional Fracture of Bioprosthetic Valve Rings as an Adjunctive Technique in Transcatheter Valve-in-Valve Replacement
    McElhinney, Doff B.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (07)