ACTIVATED SLUDGE INHIBITION CAPACITY INDEX

被引:8
|
作者
Surerus, V. [1 ]
Giordano, G. [2 ]
Teixeira, L. A. C. [1 ]
机构
[1] Pontificia Univ Catolica Rio de Janeiro, Dept Mat Engn, Rio De Janeiro, RJ, Brazil
[2] Univ Estado Rio de Janeiro, Dept Sanit & Environm Engn, BR-20550011 Rio De Janeiro, RJ, Brazil
关键词
Biological treatment; Respirometric tests; Inhibition; Oxygen uptake rate; WASTE-WATER; TOXICITY; REMOVAL; SYSTEM;
D O I
10.1590/0104-6632.20140312s00002516
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Toxic compounds in sewage or industrial wastewater may inhibit the biological activity of activated sludge impairing the treatment process. This paper evaluates the Inhibition Capacity Index (ICI) for the assessment of activated sludge in the presence of toxicants. In this study, activated sludge was obtained from industrial treatment plants and was also synthetically produced. Continuous respirometric measurements were carried out in a reactor, and the oxygen uptake rate profile obtained was used to evaluate the impact of inhibiting toxicants, such as dissolved copper, phenol, sodium alkylbenzene sulfonate and amoxicillin, on activated sludge. The results indicate that ICI is an efficient tool to quantify the intoxication capacity. The activated sludge from the pharmaceutical industry showed higher resistance than the sludge from other sources, since toxicants are widely discharged in the biological treatment system. The ICI range was from 58 to 81% when compared to the synthetic effluent with no toxic substances.
引用
收藏
页码:385 / 392
页数:8
相关论文
共 50 条
  • [21] Applicability of the Sludge Biotic Index (SBI) to municipal and industrial activated sludge plants
    Papadimitriou, Ch.
    Palaska, G.
    Lazaridou, M.
    Samaras, P.
    Sakellaropoulos, G. P.
    Proceeding of the 9th International Conference on Environmental Science and Technology Vol B - Poster Presentations, 2005, : B664 - B670
  • [22] Influence of floc size on activated sludge volume index
    Barbusinski, Krzysztof
    Environmental Protection Engineering, 2000, 26 (01): : 45 - 53
  • [23] Influence of floc size on activated sludge volume index
    Barbusiński, Krzysztof
    Environment Protection Engineering, 2000, 26 (01): : 45 - 53
  • [24] Inhibition of microbial activity of activated sludge by ammonia in leachate
    Li, XZ
    Zhao, QL
    ENVIRONMENT INTERNATIONAL, 1999, 25 (08) : 961 - 968
  • [25] INHIBITION OF NITRIFICATION IN ACTIVATED SLUDGE PROCESS OF SEWAGE DISPOSAL
    TOMLINSON, TG
    BOON, AG
    TROTMAN, CNA
    JOURNAL OF APPLIED BACTERIOLOGY, 1966, 29 (02): : 266 - +
  • [26] Microrespirometric characterization of activated sludge inhibition by copper and zinc
    Ivonne Esquivel-Rios
    Ignacio González
    Frederic Thalasso
    Biodegradation, 2014, 25 : 867 - 879
  • [27] INHIBITION COEFFICIENT (KI) DETERMINATION IN ACTIVATED-SLUDGE
    LEWANDOWSKI, Z
    JANTA, K
    MAZIERSKI, J
    WATER RESEARCH, 1985, 19 (05) : 671 - 674
  • [28] Unified basis for the respirometric evaluation of inhibition for activated sludge
    Insel, Guclu
    Karahan, Ozlen
    Ozdemir, Seda
    Pala, Llke
    Katipoglu, Tugce
    Cokgor, Emine Ubay
    Orhon, Derin
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2006, 41 (09): : 1763 - 1780
  • [29] Inhibition of Activated Sludge Respiration by Laundry Washing Agents
    Hartmann, Silvie
    Skrobankova, Hana
    Havranek, Ivo
    PROCEEDINGS OF THE 2015 AASRI INTERNATIONAL CONFERENCE ON CIRCUITS AND SYSTEMS (CAS 2015), 2015, 9 : 39 - 42
  • [30] Unified basis for the respirometric evaluation of inhibition for activated sludge
    Insel, Guclu
    Karahan, Ozlen
    Özdemir, Seda
    Pala, Llke
    Katipoǧlu, Tugce
    Cokgör, Emine
    Orhon, Derin
    Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, 2006, 41 (09): : 1763 - 1780