Spinal cord stimulation in experimental chronic painful diabetic polyneuropathy: Delayed effect of High-frequency stimulation

被引:29
|
作者
van Beek, M. [1 ,2 ]
van Kleef, M. [2 ]
Linderoth, B. [2 ,3 ]
van Kuijk, S. M. J. [4 ]
Honig, W. M. [1 ]
Joosten, E. A. [1 ,2 ]
机构
[1] Maastricht Univ, Sch Mental Hlth & Neurosci, Dept Translat Neurosci, Maastricht, Netherlands
[2] MUMC, Pain Management & Res Ctr, Dept Anesthesiol, Maastricht, Netherlands
[3] Karolinska Inst, Dept Clin Neurosci, Funct Neurosurg, Stockholm, Sweden
[4] MUMC, Dept Clin Epidemiol & Med Technol Assessment KEMT, Maastricht, Netherlands
关键词
RANDOMIZED CONTROLLED-TRIAL; CEREBROSPINAL-FLUID LEVELS; BACK SURGERY SYNDROME; LOWER-LIMB ISCHEMIA; MECHANICAL HYPERALGESIA; PERIPHERAL NEUROPATHY; NEUROTROPHIC FACTOR; TACTILE ALLODYNIA; FACTOR CORRELATE; BLOOD-FLOW;
D O I
10.1002/ejp.981
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BackgroundSpinal cord stimulation (SCS) has been shown to provide pain relief in painful diabetic polyneuropathy (PDPN). As the vasculature system plays a great role in the pathophysiology of PDPN, a potential beneficial side-effect of SCS is peripheral vasodilation, with high frequency (HF) SCS in particular. We hypothesize that HF-SCS (500Hz), compared with conventional (CON) or low frequency (LF)-SCS will result in increased alleviation of mechanical hypersensitivity in chronic experimental PDPN. MethodsDiabetes was induced in 8-week-old female Sprague-Dawley rats with an intraperitoneal injection of 65mg/kg of streptozotocin (n=44). Rats with a significant decrease in mechanical withdrawal response to von Frey filaments over a period of 20weeks were implanted with SCS electrodes (n=18). Rats were assigned to a cross-over design with a random order of LF-, CON-, HF- and sham SCS and mechanical withdrawal thresholds were assessed with von Frey testing. ResultsCompared with sham treatment, the average 50% WT score for 5Hz was 4.88g higher during stimulation (p=0.156), and 1.77g higher post-stimulation (p=0.008). CON-SCS resulted in 50% WT scores 5.7g, and 2.51g higher during (p=0.064) and after stimulation (p<0.004), respectively. HF-SCS started out with an average difference in 50% WT score compared with sham of 1.87g during stimulation (p=0.279), and subsequently the steepest rise to a difference of 5.47g post-stimulation (p<0.001). ConclusionsWe demonstrated a delayed effect of HF-SCS on mechanical hypersensitivity in chronic PDPN animals compared with LF-, or CON-SCS. SignificanceThis study evaluates the effect of SCS frequency (5-500Hz) on mechanical hypersensitivity in the chronic phase of experimental PDPN. High frequency (500Hz) - SCS resulted in a delayed effect- on pain-related behavioural outcome in chronic PDPN.
引用
收藏
页码:795 / 803
页数:9
相关论文
共 50 条
  • [41] High-frequency spinal cord stimulation at 10 kHz for the treatment of painful diabetic neuropathy: design of a multicenter, randomized controlled trial (SENZA-PDN)
    Nagy A. Mekhail
    Charles E. Argoff
    Rod S. Taylor
    Christian Nasr
    David L. Caraway
    Bradford E. Gliner
    Jeyakumar Subbaroyan
    Elizabeth S. Brooks
    Trials, 21
  • [42] Long-Term Spinal Cord Stimulation Alleviates Mechanical Hypersensitivity and Increases Peripheral Cutaneous Blood Perfusion in Experimental Painful Diabetic Polyneuropathy
    van Beek, Maarten
    Hermes, Denise
    Honig, Wiel M.
    Linderoth, Bengt
    van Kuijk, Sander M. J.
    van Kleef, Maarten
    Joosten, Elbert A.
    NEUROMODULATION, 2018, 21 (05): : 472 - 479
  • [43] High-frequency spinal cord stimulation at 10 kHz for the treatment of painful diabetic neuropathy: design of a multicenter, randomized controlled trial (SENZA-PDN)
    Mekhail, Nagy A.
    Argoff, Charles E.
    Taylor, Rod S.
    Nasr, Christian
    Caraway, David L.
    Gliner, Bradford E.
    Subbaroyan, Jeyakumar
    Brooks, Elizabeth S.
    TRIALS, 2020, 21 (01)
  • [44] Pain relief and quality-of-life improvement after spinal cord stimulation in painful diabetic polyneuropathy: a pilot study
    Pluijms, W. A.
    Slangen, R.
    Bakkers, M.
    Faber, C. G.
    Merkies, I. S. J.
    Kessels, A. G.
    Dirksen, C. D.
    Joosten, E. A.
    Reulen, J. P. H.
    van Dongen, R. T.
    Schaper, N. C.
    van Kleef, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (04) : 623 - 629
  • [45] Effects of expiratory muscle activation via high-frequency spinal cord stimulation
    Kowalski, K. E.
    Romaniuk, J. R.
    Kowalski, T.
    DiMarco, A. F.
    JOURNAL OF APPLIED PHYSIOLOGY, 2017, 123 (06) : 1525 - 1531
  • [46] Fiber Threshold Accommodation as a Mechanism of Burst and High-Frequency Spinal Cord Stimulation
    Arle, Jeffrey E.
    Mei, Longzhi
    Carlson, Kristen W.
    NEUROMODULATION, 2019, : 582 - 593
  • [47] The Evolving Role of High-Frequency Spinal Cord Stimulation as Salvage Therapy in Neurostimulation
    Ghosh, Priyanka E.
    Gill, Jatinder S.
    Simopoulos, Thomas
    PAIN PRACTICE, 2020, 20 (07) : 706 - 713
  • [48] Dorsal Root Ganglion Stimulation in Experimental Painful Diabetic Polyneuropathy: Delayed Wash-Out of Pain Relief After Low-Frequency (1Hz) Stimulation
    Koetsier, Eva
    Franken, Glenn
    Debets, Jacques
    van Kuijk, Sander M. J.
    Linderoth, Bengt
    Joosten, Elbert A.
    Maino, Paolo
    NEUROMODULATION, 2020, 23 (02): : 177 - 184
  • [49] Variables associated with nonresponders to high-frequency (10 kHz) spinal cord stimulation
    Francio, Vinicius Tieppo
    Alm, John
    Leavitt, Logan
    Mok, Daniel
    Yoon, B. Victor
    Nazir, Niaman
    Lam, Christopher
    Latif, Usman
    Sowder, Timothy
    Braun, Edward
    Sack, Andrew
    Khan, Talal
    Sayed, Dawood
    PAIN PRACTICE, 2024, 24 (04) : 584 - 599
  • [50] Sustained effect of spinal cord stimulation on pain and quality of life in painful diabetic peripheral neuropathy
    Slangen, R.
    Pluijms, W. A.
    Faber, C. G.
    Dirksen, C. D.
    Kessels, A. G. H.
    van Kleef, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (06) : 1030 - 1031