99mTc-MIBI SPECT/CT imaging contribution in the diagnosis of patients with hyperparathyroidism

被引:0
|
作者
Nevena, Manevska [1 ]
Sinisa, Stojanoski [1 ]
Bojana, Stoilovska [1 ]
Irena, Sazdova [1 ]
机构
[1] Ss Cyril & Methodius Univ, Inst Pathophysiol & Nucl Med Acad Isak S Tadzer, Fac Med, Skopje, Macedonia
来源
IRANIAN JOURNAL OF NUCLEAR MEDICINE | 2019年 / 27卷 / 01期
关键词
Hyperparathyroidism; Parathyroid; SPECT/CT; Tc-99m-MIBI; Ultrasound; PARATHYROID ADENOMAS; TC-99M-SESTAMIBI SCINTIGRAPHY; PREOPERATIVE LOCALIZATION; SUBTRACTION SCINTIGRAPHY; TRACER SUBTRACTION; SESTAMIBI SPECT; PHASE; TECHNETIUM-99M-SESTAMIBI; SONOGRAPHY; ULTRASOUND;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Hyperparathyroidism is presented with increased parathyroid hormone (PTH) secretion due to hyperfunctioning of one or more of the four parathyroid glands. Primary hyperparathyroidism (p-HPT) can be due to parathyroid adenoma, hyperplasia or carcinoma of the parathyroid gland. Secondary hyperparathyroidism (s-HPT) is usually a response to hypocalcaemia and consecutive hyperplasia of the glands. Our aim was to compare the efficacy of (99m)Tcmethoxyisobutylisonitrile (MIBI) SPECT/CT in identification of the location of the lesion(s) in cases of HPT by comparing these results with the findings of ultrasound (US) and planar scintigraphy. Methods: Forty one consecutive patients (54 +/- 17 age, 12 males and 29 females) with primary or secondary hyperparathyroidism were included. All patients were examined by US and afterwards patients underwent conventional double-phase Tc-99m-MIBI scintigraphy combined with neck SPECT/CT procedure. Planar images (early and delayed), US and SPECT/CT image sets were evaluated for adenoma localization at the neck and thorax. Regions of interest (ROIs), equal sized, were selected and compared, over the hyperfunctioning parathyroid tissue (accumulated impulses-counts value) and over the contralateral lobe of the thyroid gland (control counts value). Results: The ultrasonography detected 24 positive findings. The late phase of planar scan detected 26 positive findings. SPECT/CT presented with bigger detection rate than late planar phase or US (75.6%, 63.4%, 61.5%) and with higher sensitivity (100%, 83.8%, 77.4%), respectively. Conclusion: The SPECT/CT study seems reliable, sensitive and with added value in diagnosing hyperparathyroidism as a complementary method to planar scintigraphy. US as compatible method, should be performed prior the scintigraphy protocols.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [41] Semi-quantitative Analysis of 99mTc-MIBI SPECT/CT in Distinguishing Between Renal Secondary Hyperparathyroidism and Tertiary Hyperparathyroidism
    Cheng, Junjun
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [42] Recurrent secondary hyperparathyroidism following parathyroidectomy with autotransplantation. Parathyroid scintigraphy with 99mTc-MIBI SPECT/CT
    Zeidan Ramon, N.
    Garcia Lucero, M. E.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2019, 38 (05): : 320 - 321
  • [43] Usefulness of Preoperative 99mTc-MIBI SPECT-CT in Primary Hyperparathyroidism: Correlation with Radioguided Surgery Findings
    Prieto Soriano, A.
    Salazar Anda, G.
    Cardona Arbonies, J.
    Ortega Candil, A.
    Rodriguez Rey, C.
    Gonzalez Mate, A.
    Ochagava Camara, S.
    Ildefonso Martin, J. A.
    Lapena Gutierrez, L.
    Carreras Delgado, J. L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S253 - S253
  • [44] The role of99mTc-MIBI SPECT/CT in patients with secondary hyperparathyroidism: comparison with99mTc-MIBI planar scintigraphy and ultrasonography
    Jiang, Shu-Qin
    Yang, Ting
    Zou, Qiong
    Xu, Lei
    Ye, Ting
    Kang, Yin-Qian
    Li, Wan-Ru
    Jiao, Ju
    Zhang, Yong
    BMC MEDICAL IMAGING, 2020, 20 (01)
  • [45] 99mTc-MIBI pinhole SPECT in primary hyperparathyroidism:: comparison with conventional SPECT, planar scintigraphy and ultrasonography
    Carlier, Thomas
    Oudoux, Aurore
    Mirallie, Eric
    Seret, Alain
    Daumy, Isabelle
    Leux, Christophe
    Bodet-Milin, Caroline
    Kraeber-Bodere, Francoise
    Ansquer, Catherine
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (03) : 637 - 643
  • [46] 99mTc-MIBI pinhole SPECT in primary hyperparathyroidism: comparison with conventional SPECT, planar scintigraphy and ultrasonography
    Thomas Carlier
    Aurore Oudoux
    Eric Mirallié
    Alain Seret
    Isabelle Daumy
    Christophe Leux
    Caroline Bodet-Milin
    Françoise Kraeber-Bodéré
    Catherine Ansquer
    European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 : 637 - 643
  • [47] The Value of 99mTc-MIBI SPECT/CT in the Postoperative Assessment of Patients with Differentiated Thyroid Carcinoma
    Okudan, Berna
    Seven, Bedri
    Gulaldi, Nedim C. M.
    Capraz, Mustafa
    Acikgoz, Yusuf
    CURRENT MEDICAL IMAGING, 2022, 18 (04) : 404 - 408
  • [48] 99mTc-MIBI SPECT in the study of brain lymphoma
    Mena, L. M.
    Martin, F.
    Bravo, C.
    Santos, A. B.
    Escabia, M. V.
    Jimenez, I. R.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR, 2011, 30 (06): : 380 - 381
  • [49] 99mTc-MIBI SPECT/CT in the diagnostics of chronic postsurgical sternum osteomyelitis
    Kurazhov, A.
    Zorkaltsev, M.
    Zavadovskaia, V.
    Kilina, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S589 - S589
  • [50] Comparative Analysis of Diagnostic Efficacy in Primary Hyperparathyroidism: A Comparison Analysis of 11C-Choline PET/CT, Neck Ultrasonography, 99mTc-MIBI Dual-Phase Planar Scintigraphy, and 99mTc-MIBI SPECT/CT Imaging
    Zhang, Zhining
    Zhao, Min
    Chen, Bin
    Cao, Yiming
    Gao, Shi
    JOURNAL OF CANCER, 2024, 15 (07): : 1863 - 1869