Quantifying optic nerve axons in a cat glaucoma model by a semi-automated targeted counting method

被引:0
|
作者
Teixeira, Leandro B. C. [1 ,2 ]
Buhr, Kevin A. [3 ]
Bowie, Owen [4 ]
Duke, Felicia D. [1 ,2 ]
Nork, T. Michael [2 ,4 ]
Dubielzig, Richard R. [1 ,2 ]
McLellan, Gillian J. [2 ,4 ,5 ]
机构
[1] Univ Wisconsin, Sch Vet Med, Dept Pathobiol Sci, Madison, WI 53792 USA
[2] Univ Wisconsin, McPherson Eye Res Inst, Madison, WI 53792 USA
[3] Univ Wisconsin, Dept Biostat & Med Informat, Madison, WI 53792 USA
[4] Univ Wisconsin, Sch Med & Publ Hlth, Dept Ophthalmol & Visual Sci, Madison, WI 53792 USA
[5] Univ Wisconsin, Sch Vet Med, Dept Surg Sci, Madison, WI 53792 USA
来源
MOLECULAR VISION | 2014年 / 20卷
关键词
RETINAL GANGLION-CELL; AMACRINE CELLS; RAT MODEL; POPULATION; ORGANIZATION; NUMBER; LAYER;
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Purpose: To describe and validate a semi-automated targeted sampling (SATS) method for quantifying optic nerve axons in a feline glaucoma model. Methods: Optic nerve cross sections were obtained from 15 cats, nine with mild to severe glaucoma and six with normal eyes. Optic nerves were dissected, fixed in paraformaldehyde and glutaraldehyde, and processed for light microscopy by resin embedding, sectioning, and staining of axon myelin sheaths with 1% p-phenylenediamine before axon quantification. Commercially available image analysis software was used as a semi-automated axon counting tool (SCT) and was first validated by comparison with a manual axon count (MAC). This counting tool was then used in a SATS method performed by three masked raters and in a semi-automated full count (SAFC) method performed by a single observer. Correlation was assessed between the SCT and MAC using a linear model and analysis of covariance (ANCOVA). Correlation between the SATS and SAFC methods was calculated and the bias, systematic errors, and variance component assessed. The intraclass correlation coefficient (ICC) was determined to establish inter-rater agreement. In addition, the time required to perform the SATS and SAFC methods was evaluated. Results: Correlation between the axon counts obtained by the SCT and MAC was strong (r = 0.9985). There was evidence of an overcounting of axons by the SCT compared to the MAC with a percentage error rate of 13.0% (95% confidence interval [CI] 11.0%, 15.1%). Both the correlation of SATS count (average per rater) to SAFC (r = 0.9891) and inter-rater agreement (ICC = 0.986) were high. The SATS method presented an overall positive counting error (p<0.001) when compared to the SAFC, consistent with a fixed percentage overestimation of 11.2% (95% CI 8.3%, 14.2%) of the full count. The average time required to quantify axons by the SATS method was 10.9 min, only 27% of that required to conduct the SAFC. Conclusions: Our data demonstrate that the SATS method provides a practical, rapid, and reliable means of estimating axon counts in the optic nerves of cats with glaucoma.
引用
收藏
页码:376 / 385
页数:10
相关论文
共 39 条
  • [21] Comparison of a semi-automated new Coulter methylene blue method with fluorescence flow cytometry in reticulocyte counting
    Rudensky, B
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1997, 57 (04): : 291 - 296
  • [22] Immature reticulocyte fraction as a criterion for marrow engraftment. Evaluation of a semi-automated reticulocyte counting method
    Grotto, HZW
    Vigoritto, AC
    Noronha, JFA
    Lima, GALM
    CLINICAL AND LABORATORY HAEMATOLOGY, 1999, 21 (04): : 285 - 287
  • [23] The development of honey bee colonies assessed using a new semi-automated brood counting method: CombCount
    Colin, Theotime
    Bruce, Jake
    Meikle, William G.
    Barron, Andrew B.
    PLOS ONE, 2018, 13 (10):
  • [24] A semi-automated method for unbiased alveolar morphometry: Validation in a bronchopulmonary dysplasia model
    Salaets, Thomas
    Tack, Bieke
    Gie, Andre
    Pavie, Benjamin
    Sindhwani, Nikhil
    Jimenez, Julio
    Regin, Yannick
    Allegaert, Karel
    Deprest, Jan
    Toelen, Jaan
    PLOS ONE, 2020, 15 (09):
  • [25] A semi-automated method for identifying and measuring myelinated nerve fibers in scanning electron microscope images
    More, Heather L.
    Chen, Jingyun
    Gibson, Eli
    Donelan, J. Maxwell
    Beg, Mirza Faisal
    JOURNAL OF NEUROSCIENCE METHODS, 2011, 201 (01) : 149 - 158
  • [26] A semi-automated analysis method of small sensory nerve fibers in human skin-biopsies
    Tamura, Kazuyuki
    Mager, Violet A.
    Burnett, Lindsey A.
    Olson, John H.
    Brower, Jeremy B.
    Casano, Ashley R.
    Baluch, Debra P.
    Targovnik, Jerome H.
    Windhorst, Rogier A.
    Herman, Richard M.
    JOURNAL OF NEUROSCIENCE METHODS, 2010, 185 (02) : 325 - 337
  • [27] AN ImageJ-BASED ALGORITHM FOR A SEMI-AUTOMATED METHOD FOR MICROSCOPIC IMAGE ENHANCEMENT AND DNA REPAIR FOCI COUNTING
    Klokov, Dmitry
    Suppiah, Roopa
    AECL NUCLEAR REVIEW, 2015, 4 (01): : 75 - 82
  • [28] Semi-Automated Volumetric Quantifying Method of Cerebral Microhemorrhage Using T2*-Weighted MRI Images
    Bahrani, Ahmed A.
    Al-Janabi, Omar Mi
    Yu, Guoqiang
    Wilcock, Donna M.
    Smith, Charles D.
    Jicha, Gregory A.
    ANNALS OF NEUROLOGY, 2018, 84 : S166 - S166
  • [29] A highly accurate and semi-automated method for quantifying spherical microplastics based on digital slide scanners and image processing
    Tang, Yu
    Yao, Jie
    Dong, Zekun
    Hu, Zhihui
    Wu, Tongqing
    Zhang, Yan
    ENVIRONMENTAL RESEARCH, 2024, 250
  • [30] Retinal ganglion cells downregulate gene expression and lose their Axons within the optic nerve head in a mouse glaucoma model
    Soto, Ileana
    Oglesby, Ericka
    Buckingham, Brian P.
    Son, Janice L.
    Roberson, Elisha D. O.
    Steele, Michael R.
    Inman, Denise M.
    Vetter, Monica L.
    Horner, Philip J.
    Marsh-Armstrong, Nicholas
    JOURNAL OF NEUROSCIENCE, 2008, 28 (02): : 548 - 561