A Mechatronic System for Quantitative Application and Assessment of Massage-Like Actions in Small Animals

被引:18
|
作者
Wang, Qian [1 ]
Zeng, Hansong [1 ]
Best, Thomas M. [1 ,2 ,3 ]
Haas, Caroline [1 ,2 ]
Heffner, Ned T. [1 ]
Agarwal, Sudha [1 ,4 ]
Zhao, Yi [1 ,5 ]
机构
[1] Ohio State Univ, Coll Engn, Dept Biomed Engn, Columbus, OH 43210 USA
[2] Ohio State Univ, Coll Med, Div Sports Med, Dept Family Med, Columbus, OH 43210 USA
[3] Ohio State Univ, Sports Hlth & Performance Inst, Columbus, OH 43210 USA
[4] Ohio State Univ, Coll Dent, Div Oral Biol, Columbus, OH 43210 USA
[5] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
基金
美国国家卫生研究院;
关键词
Medical devices; Massage therapy; Mechanics; Viscoelasticity; CEREBRAL-BLOOD-FLOW; SKELETAL-MUSCLE; RECOVERY; THERAPY; PILOT; ADOLESCENTS; PERFORMANCE; LIMB;
D O I
10.1007/s10439-013-0886-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Massage therapy has a long history and has been widely believed effective in restoring tissue function, relieving pain and stress, and promoting overall well-being. However, the application of massage-like actions and the efficacy of massage are largely based on anecdotal experiences that are difficult to define and measure. This leads to a somewhat limited evidence-based interface of massage therapy with modern medicine. In this study, we introduce a mechatronic device that delivers highly reproducible massage-like mechanical loads to the hind limbs of small animals (rats and rabbits), where various massage-like actions are quantified by the loading parameters (magnitude, frequency and duration) of the compressive and transverse forces on the subject tissues. The effect of massage is measured by the difference in passive viscoelastic properties of the subject tissues before and after mechanical loading, both obtained by the same device. Results show that this device is useful in identifying the loading parameters that are most conducive to a change in tissue mechanical properties, and can determine the range of loading parameters that result in sustained changes in tissue mechanical properties and function. This device presents the first step in our effort for quantifying the application of massage-like actions used clinically and measurement of their efficacy that can readily be combined with various quantitative measures (e. g., active mechanical properties and physiological assays) for determining the therapeutic and mechanistic effects of massage therapies.
引用
收藏
页码:36 / 49
页数:14
相关论文
共 50 条
  • [31] Design and assessment of a novel SPECT system for desktop open-gantry imaging of small animals: A simulation study
    Zeraatkar, Navid
    Farahani, Mohammad Hossein
    Rahmim, Arman
    Sarkar, Saeed
    Ay, Mohammad Reza
    MEDICAL PHYSICS, 2016, 43 (05) : 2581 - 2597
  • [32] Diversity Assessment Method and Its Application in I & C System of Offshore Small Modular Reactor
    Yang Y.
    Wang Y.
    Xiong G.
    Wang H.
    Guo Y.
    Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (02): : 68 - 73
  • [33] Comparative assessment for the feasibility of storage bank in small scale power photovoltaic pumping system for building application
    Mohammedi, Ahmed
    Rekioua, Djamila
    Rekioua, Toufik
    Mebarki, Nasser Eddine
    ENERGY CONVERSION AND MANAGEMENT, 2018, 172 : 579 - 587
  • [34] Evaluating small-scale eucalyptus growers' experience of the EVO mobile application: a comparative analysis of quantitative and qualitative assessment techniques
    Kaakkurivaara, Nopparat
    Takuathung, Chakrit Na
    Diloksumpun, Piyawat
    Yingdee, Jirawat
    Jumwong, Narinthorn
    Meunpong, Ponthep
    Sangvisitpirom, Pattama
    Tangkit, Kitipong
    Neimsuwan, Trairat
    Kaakkurivaara, Tomi
    FORESTS TREES AND LIVELIHOODS, 2024,
  • [35] APPLICATION OF QUANTITATIVE CORONARY ANGIOGRAPHY IN A CINELESS ENVIRONMENT - IN-VIVO ASSESSMENT OF A FULLY AUTOMATED-SYSTEM FOR CLINICAL USE
    CUSMA, JT
    SPERO, LA
    VANDERGEEST, RJ
    BASHORE, TM
    MORRIS, KG
    AMERICAN HEART JOURNAL, 1995, 129 (02) : 300 - 306
  • [36] Development and application of safety culture analysis program: First online safety culture quantitative analysis and assessment system in China
    Xie, Xuecai
    Fu, Gui
    Shi, Zhao
    Tong, Ruipeng
    Tong, Wenqing
    Lyu, Qian
    Wang, Yuxin
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2024, 89
  • [37] Application of Multi-Dimensional Intelligent Visual Quantitative Assessment System to Evaluate Hand Function Rehabilitation in Stroke Patients
    Du, Yuying
    Shi, Yu
    Ma, Hongmei
    Li, Dong
    Su, Ting
    Meidege, Ou Zhabayier
    Wang, Baolan
    Lu, Xiaofeng
    BRAIN SCIENCES, 2022, 12 (12)
  • [38] Small-Sized Parabolic Trough Collector System for Solar Dehumidification Application: Design, Development, and Potential Assessment
    Chaudhary, Ghulam Qadar
    Kousar, Rubeena
    Ali, Muzaffar
    Amar, Muhammad
    Amber, Khuram Pervez
    Lodhi, Shabaz Khan
    Din, Muhammad Rameez ud
    Ditta, Allah
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2018, 2018
  • [39] Application of Open AI in Small and Medium-Sized Enterprise (SME) Risk Assessment and Financial Analysis System
    Kang, Chia-Chun
    Zhang, Li-Jie
    Wang, Jie-Mie
    Lin, Chi-Hsu
    KNOWLEDGE MANAGEMENT IN ORGANISATIONS, KMO 2024, 2024, 2152 : 331 - 340
  • [40] Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis
    Carrol, Enitan D.
    Salway, Fiona
    Pepper, Stuart D.
    Saunders, Emma
    Mankhambo, Limangeni A.
    Ollier, William E.
    Hart, C. Anthony
    Day, Phillip
    BMC IMMUNOLOGY, 2007, 8 (1)