Correlation between liver signal intensity in hepatobiliary phase of Gd-EOB-DTPA enhancement and liver function reserves

被引:1
|
作者
Tanpowpong, Natthaporn [1 ]
Phewplung, Teerasak [1 ]
机构
[1] Chulalongkorn Univ, Dept Radiol, Fac Med, Bangkok 10330, Thailand
关键词
Liver functional reserves; model score for end-stage liver disease; signal intensity; CLINICAL-EVALUATION; CONTRAST AGENT; SAFETY; SURVIVAL; MODEL; MRI;
D O I
10.5372/1905-7415.0803.308
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Gadolinium diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA) is a developed agent with preferential uptake by hepatocytes. A rapid and specific hepatocyte uptake with biliary excretion was observed of approximately 50% of the injected dose. The amount of contrast uptake is thought to be related to reserve liver function. Objectives: To evaluate orrelation between liver signal intensity in the hepatobiliary phase of Gd-EOB-DTPA and reserved liver function by using the model score for end-stage liver disease (MELD). Methods: All patients who underwent magnetic resonance (MR) imaging with Gd-EOB-DTPA were retrospectively collected. The patients with serum creatinine level higher than 1.5 mg/dL or patients without available data to estimate MELD score were excluded. Thirty-six patients were enrolled. A signal-to-noise ratio (SNR) in the liver parenchyma on a fat-suppressed three dimensional fast spoiled-gradient recalled echo sequence images before and 20 minutes after contrast injection were measured and calculated on PACS by two radiologists. The MELD score was determined and interobserver reliability was estimated. Results: Among 36 patients, we found a negative relationship between the percentage enhancement and the MELD score (P < 0.01, r = 0.545). The SNR at 20 minutes after Gd-EOB-DTPA injection also had a negative relationship with the MELD score with statistical significance (P < 0.01, r = 0.460). Interobserver reliability was 0.675. Conclusion: The percentage enhancement in hepatobiliary phase of Gd-EOB-DTPA can predict reserved liver function.
引用
收藏
页码:411 / 415
页数:5
相关论文
共 50 条
  • [21] Liver tumors: Comparison of MR imaging with Gd-EOB-DTPA and Gd-DTPA
    Vogl, TJ
    Kummel, S
    Hammerstingl, R
    Schellenbeck, M
    Schumacher, G
    Balzer, T
    Schwarz, W
    Muller, PK
    Bechstein, WO
    Mack, MG
    Sollner, O
    Felix, R
    RADIOLOGY, 1996, 200 (01) : 59 - 67
  • [22] Dynamic MR imaging of liver metastases with Gd-EOB-DTPA
    Stern, W
    Schick, F
    Kopp, AF
    Reimer, P
    Shamsi, K
    Claussen, CD
    Laniado, M
    ACTA RADIOLOGICA, 2000, 41 (03) : 255 - 262
  • [23] The relaxivity of Gd-EOB-DTPA and Gd-DTPA in liver and kidney of the Wistar rat
    Shuter, B
    Tofts, PS
    Wang, SC
    Pope, JM
    MAGNETIC RESONANCE IMAGING, 1996, 14 (03) : 243 - 253
  • [24] T2-Weighted Magnetic Resonance Imaging of the Liver: Evaluation of the Effect in Signal Intensity After Gd-EOB-DTPA Enhancement
    Tamada, Tsutomu
    Ito, Katsuyoshi
    Yoshida, Koji
    Sone, Teruki
    Murakami, Koichi
    Kanki, Akihiko
    Watanabe, Shigeru
    Higashi, Hiroki
    Yamashita, Takenori
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (02) : 182 - 186
  • [25] Focal liver lesion detection and characterization with GD-EOB-DTPA
    Purysko, A. S.
    Remer, E. M.
    Veniero, J. C.
    CLINICAL RADIOLOGY, 2011, 66 (07) : 673 - 684
  • [26] Comparison Between Areas With Gd-EOB-DTPA Uptake and Without in Hepatocellular Carcinomas on Gd-EOB-DTPA-Enhanced Hepatobiliary-Phase MR Imaging: Pathological Correlation
    Lee, Sanghee
    Kim, Seong Hyun
    Park, Cheol Keun
    Kim, Young-sun
    Lee, Won Jae
    Lim, Hyo K.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (03) : 719 - 725
  • [27] MR Imaging of Carcinosarcoma of the Liver using Gd-EOB-DTPA
    Yasutake, Tsuyoshi
    Kiryu, Shigeru
    Akai, Hiroyuki
    Watadani, Takeyuki
    Akahane, Masaaki
    Tomizawa, Nobuo
    Gonoi, Wataru
    Ikemura, Masako
    Takahashi, Masamichi
    Matsuoka, Yujiro
    Ohtomo, Kuni
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2014, 13 (02) : 117 - 121
  • [28] Effect of hepatobiliary uptake of Gd-EOB-DTPA on the hepatic venous phase of dynamic magnetic resonance imaging on a 3.0-T apparatus: comparison between Gd-EOB-DTPA and Gd-DTPA
    Yasunari Fujinaga
    Ayumi Ohya
    Tsuyoshi Matsushita
    Masahiro Kurozumi
    Kazuhiko Ueda
    Yoshihiro Kitou
    Hitoshi Ueda
    Masumi Kadoya
    Japanese Journal of Radiology, 2011, 29 : 695 - 700
  • [29] Effect of hepatobiliary uptake of Gd-EOB-DTPA on the hepatic venous phase of dynamic magnetic resonance imaging on a 3.0-T apparatus: comparison between Gd-EOB-DTPA and Gd-DTPA
    Fujinaga, Yasunari
    Ohya, Ayumi
    Matsushita, Tsuyoshi
    Kurozumi, Masahiro
    Ueda, Kazuhiko
    Kitou, Yoshihiro
    Ueda, Hitoshi
    Kadoya, Masumi
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (10) : 695 - 700
  • [30] MR Prediction of Liver Function and Pathology Using Gd-EOB-DTPA: Effect of Liver Volume Consideration
    Shimamoto, Dai
    Nishie, Akihiro
    Asayama, Yoshiki
    Ushijima, Yasuhiro
    Takayama, Yukihisa
    Fujita, Nobuhiro
    Shirabe, Ken
    Hida, Tomoyuki
    Kubo, Yuichiro
    Honda, Hiroshi
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015