A nondestructive calibration method for maximizing the range and accuracy of AFM force measurement

被引:3
|
作者
Xie, Hui [1 ]
Rong, Weibin [1 ]
Wu, Aiwen [1 ]
Sun, Lining [1 ]
机构
[1] Harbin Inst Technol, State Key Lab Robot & Syst, Harbin 150080, Peoples R China
基金
对外科技合作项目(国际科技项目);
关键词
atomic force microscope; nondestructive calibration; nonlinear compensation; dual-probe; MICROSCOPY; FRICTION; CANTILEVER; SURFACE; TIP;
D O I
10.1088/0960-1317/24/2/025005
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a nondestructive method for the normal and lateral sensitivity calibrations of the optical lever in atomic force microscope (AFM) is presented. The practical application of this method in a dual-probe AFM is discussed in detail. To calibrate the conversion factors between photodiode responses and probe's deflection angles accurately without applying forces to the probe, a two-degrees-of-freedom flexure-hinge-based calibration device (FHCD) is developed. The device, which mainly consists of two mutually perpendicular flexure-hinge levers that share the same rotational center, serves as a switching mechanism for precise translation-to-rotation conversions both in the normal and lateral directions. During the calibration, a probe is attached to the FHCD at the meeting of the rotational axes of two levers. The FHCD is mounted on an AFM sample platform. The probe in this method acts as a mirror to be normally and laterally tilted at nanoscale angles to deflect the reflected laser beam by twisting the corresponding flexure-hinge levers, rather than the force-inducing probe deflection in traditional AFM calibration methods. With this method, the nondestructive calibration of the local and full-range sensitivities of the optical levers can be completed without destroying the probe tip or modifying the actual system setup of an AFM. Moreover, the nonlinearities of the optical levers are accurately compensated. Experimental results show that the linear ranges (with a deviation of 5% in the full range) of the force measurement are extended to 3.6 and 4.5 times in the normal and lateral directions, respectively, increasing to over 90% of the full range of the force measurement.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Force measurement by AFM cantilever with different coating layers
    Yeh, Meng-Kao
    Chen, Bo-Yi
    Tai, Nyan-Hwa
    Chiu, Chien-Chao
    Experimental Mechanics in Nano and Biotechnology, Pts 1 and 2, 2006, 326-328 : 377 - 380
  • [32] Normal Force Calibration Method Used for Calibration of Atomic Force Microscope
    Ekwinska, M.
    Rymuza, Z.
    ACTA PHYSICA POLONICA A, 2009, 116 : S78 - S81
  • [33] Correction method for dynamic measurement with an optical lever AFM (Effects of ambient fluid and surface force)
    Hanamitsu, Yuki
    Ishikawa, Takumi
    Matsuoka, Hiroshige
    JOURNAL OF ADVANCED MECHANICAL DESIGN SYSTEMS AND MANUFACTURING, 2023, 17 (04)
  • [34] MEASUREMENT OF MICROTOPOGRAPHY - STM AFM METHOD
    SAKAI, F
    JOURNAL OF JAPANESE SOCIETY OF TRIBOLOGISTS, 1990, 35 (11) : 810 - 813
  • [35] Force measurement method and calibration technology of aeroengine whole thrust test bed
    Ding X.
    Feng C.
    Xue W.
    Song J.
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2023, 38 (01): : 144 - 150
  • [36] Dynamic range measurement and calibration of SiPMs
    Bretz, T.
    Hebbeker, T.
    Lauscher, M.
    Middendorf, L.
    Niggemann, T.
    Schumacher, J.
    Stephan, M.
    Bueno, A.
    Navas, S.
    Ruiz, A. G.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [37] Force-Compensating MEMS Sensor for AFM Cantilever Stiffness Calibration
    Coskun, M. Bulut
    Moore, Steven
    Moheimani, S. O. Reza
    Neild, Adrian
    Alan, Tuncay
    2014 IEEE SENSORS, 2014, : 1745 - 1748
  • [38] Extending the Range for Force Calibration in Magnetic Tweezers
    Daldrop, Peter
    Brutzer, Hergen
    Huhle, Alexander
    Kauert, Dominik J.
    Seidel, Ralf
    BIOPHYSICAL JOURNAL, 2015, 108 (10) : 2550 - 2561
  • [39] Calibration of high magnification in the measurement of critical dimension by AFM and SEM
    Kwak, Gyea Young
    Chang, Hye Jung
    Na, Min Young
    Ryu, Seo Kyoung
    Kim, Tae Gun
    Woo, Jin Chun
    Kim, Kyung Joong
    APPLIED SURFACE SCIENCE, 2021, 565 (565)
  • [40] Inter laboratory round robin on cantilever calibration for AFM force spectroscopy
    te Riet, Joost
    Katan, Allard J.
    Rankl, Christian
    Stahl, Stefan W.
    van Buul, Arend M.
    Phang, In Yee
    Gomez-Casado, Alberto
    Schon, Peter
    Gerritsen, Jan W.
    Cambi, Alessandra
    Rowan, Alan E.
    Vancso, G. Julius
    Jonkheijm, Pascal
    Huskens, Jurriaan
    Oosterkamp, Tjerk H.
    Gaub, Hermann
    Hinterdorfer, Peter
    Figdor, Carl G.
    Speller, Sylvia
    ULTRAMICROSCOPY, 2011, 111 (12) : 1659 - 1669