Comparison of Seismic Response Characteristics Between Non Base-isolated and Base-isolated Building

被引:0
|
作者
Enomoto, Takahisa [1 ]
Ninomiya, Masayuki [2 ]
Navarro, Manuel [3 ]
机构
[1] Kanagawa Univ, Dept Architecture, Yokohama, Kanagawa 2218686, Japan
[2] Kozo Keikaku Engn Inc, Dept Struct Design, Nakano Ku, Tokyo 1640012, Japan
[3] Almeria Univ, Dept Appl Phys, Almeria 4120, Spain
关键词
Base isolated structure; Non-base isolated structure; Earthquake response characteristics; Earthquake observation records;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In Yokohama Campus of Kanagawa University, dynamic behavior observation system was installed in two buildings and surrounding ground in 2001. The buildings are two types, one is a non-base isolated building and the other one is a base isolated building with 8 stories and 1 or 2 base floors. We have many seismic records at these different structural buildings. So, we investigated the response characteristics and compared the difference of earthquake response characteristics by using the observed records.
引用
收藏
页码:2797 / 2804
页数:8
相关论文
共 50 条
  • [41] Footfall Induced Vibration Response of a Base-Isolated Steel Building
    Malhotra R.
    Ndarowa C.
    Macrae G.A.
    Palermo A.
    Broglio S.
    Malhotra, Raunaq (rma184@uclive.ac.nz), 2018, Trans Tech Publications Ltd (763 KEM) : 992 - 1001
  • [42] Response of base-isolated USC hospital building in Northridge earthquake
    Nagarajaiah, S
    Sun, XH
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2000, 126 (10): : 1177 - 1186
  • [43] INFLUENCE OF HIGH INITIAL ISOLATOR STIFFNESS ON THE SEISMIC RESPONSE OF A BASE-ISOLATED BENCHMARK BUILDING
    Sharma, Ajay
    Jangid, R. S.
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2011, 11 (06) : 1201 - 1228
  • [44] Experiments on a base-isolated building in Santiago, Chile
    Univ of Chile, Santiago, Chile
    Eng Struct, 8 (720-725):
  • [45] Semi-active seismic response control of base-isolated building with MR damper
    Soda, S
    Kusumoto, H
    Chatani, R
    Iwata, N
    Fujitani, H
    Shiozaki, Y
    Hiwatashi, T
    SMART STRUCTURES AND MATERIALS 2003: DAMPING AND ISOLATION, 2003, 5052 : 460 - 467
  • [46] A Velocity-Based Seismic Control for Base-Isolated Building Structures
    Pozo, Francesc
    Acho, Leonardo
    Rodellar, Jose
    Maria Rossell, Josep
    2009 AMERICAN CONTROL CONFERENCE, VOLS 1-9, 2009, : 3908 - +
  • [47] Design considerations for a base-isolated demonstration building
    Taniwangsa, W
    EARTHQUAKE SPECTRA, 2002, 18 (04) : 761 - 776
  • [48] Prediction of observed response of base-isolated structure
    Makris, N
    Deoskar, HS
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (05): : 485 - 493
  • [49] Response speectrum theory of base-isolated structure
    Liu, P
    Li, Q
    Gao, MH
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON COMPUTING IN CIVIL AND BUILDING ENGINEERING, VOLS 1-4, 1997, : 1259 - 1264
  • [50] DAMPING EFFECTS ON THE SEISMIC RESPONSE OF BASE-ISOLATED STRUCTURES WITH LRB DEVICES
    Avossa, Alberto Maria
    Pianese, Giovanna
    INGEGNERIA SISMICA, 2017, 34 (02): : 3 - 30