Performance enhancement of an air-coupled multiple moving membrane capacitive micromachined ultrasonic transducer using an optimized middle plate configuration

被引:1
|
作者
Emadi, Arezoo [1 ]
Buchanan, Douglas [1 ]
机构
[1] Univ Manitoba, Fac Engn, Dept Elect & Comp Engn, 75 Chancellors Circle, Winnipeg, MB R3T 5VR, Canada
来源
基金
加拿大自然科学与工程研究理事会;
关键词
middle deflectable plate; multiple moving membrane capacitive micromachined ultrasonic transducer; resonant frequency; sacrificial layer; FABRICATION; ARRAYS;
D O I
10.1117/1.JMM.15.4.045004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A multiple moving membrane capacitive micromachined ultrasonic transducer has been developed. This transducer cell structure includes a second flexible plate suspended between the transducer top plate and the fixed bottom electrode. The added plate influences the transducer top plate deflection map and, therefore, the transducer properties. Three series of individual air-coupled, dual deflectable plate transducers and two 1 x 27 element transducer arrays were fabricated using multiuser microelectromechanical systems (MEMS) processes (MUMPs). Each set of transducers included devices with middle plate radii from 22% to 65% of the corresponding transducer top plate radius. The effect of the transducer middle plate configuration has been investigated. Electrical, optical, and acoustic characterizations were conducted and the results were compared with the simulation findings. It was found that the transducer top plate amplitude of vibration is significantly enhanced with a wider middle deflectable plate. The electrical and optical measurement results are shown to be in good agreement with simulation results. The acoustic measurement results indicated a 37% increase in the amplitude of transmitted signal by the 1-MHz air-couple transducer when its middle plate radius was increased by 35%. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Design and Fabrication of Wideband Air-Coupled Capacitive Micromachined Ultrasonic Transducers With Varying Width Annular-Ring and Spiral Cell Structures
    Adelegan, Oluwafemi Joel
    Coutant, Zachary A.
    Wu, Xun
    Yamaner, Feysel Yalcin
    Oralkan, Omer
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (08) : 2749 - 2759
  • [42] Delamination detection in composite beams using pure Lamb mode generated by air-coupled ultrasonic transducer
    Liu, Zenghua
    Yu, Hongtao
    He, Cunfu
    Wu, Bin
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2014, 25 (05) : 541 - 550
  • [43] Comparative Study of Laser Doppler Vibrometer and Capacitive Air-coupled Transducer for Ultrasonic Propagation Imager and the New Development of an Efficient Ultrasonic Wavenumber Imaging Algorithm
    Truong, C. T.
    Kang, D. -H.
    Lee, J. -R.
    Farrar, C. R.
    STRAIN, 2015, 51 (04): : 332 - 342
  • [44] Optimized Design of High-Temperature Resistant Air-Coupled Ultrasonic Transducer (ACUT) Based on Single Acoustic Matching Layer
    Zhang, Liang
    Xu, Xinhu
    Wang, Xiaojie
    Li, Lei
    Guo, Hulin
    Kong, Lingcai
    Shi, Wanglong
    Zang, Jinliang
    IEEE SENSORS JOURNAL, 2024, 24 (17) : 27340 - 27351
  • [45] Air-coupled through-transmission fan-beam tomography using divergent capacitive ultrasonic transducers
    Wright, WMD
    Ingleby, P
    O'Sullivan, IJ
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (12) : 2384 - 2394
  • [46] Capacitive micromachined ultrasonic transducer: transmission performance evaluation under different driving parameters and membrane stress for underwater imaging applications
    Yasar, Abdullah Irfan
    Yildiz, Fikret
    Erogul, Osman
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2020, 26 (12): : 3601 - 3611
  • [47] Capacitive micromachined ultrasonic transducer: transmission performance evaluation under different driving parameters and membrane stress for underwater imaging applications
    Abdullah İrfan Yaşar
    Fikret Yıldız
    Osman Eroğul
    Microsystem Technologies, 2020, 26 : 3601 - 3611
  • [48] Submicrometer-order displacement measurements using an air-coupled ultrasonic transducer at frequencies of 40 and 400 kHz
    Sasaki, K
    Nishihira, M
    Imano, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2004, 43 (5B): : 3071 - 3075
  • [49] The excitation and detection of Lamb waves in a droplet-loaded plate using air-coupled ultrasonic transducers
    Fan, Zichuan
    Zhou, Yang
    Wu, Tanghong
    Peng, Peng
    MEASUREMENT, 2021, 172
  • [50] Ultrasonic guided-wave mode identification in pipe by using air-coupled transducer and time-frequency analysis
    Park, Ik-Keun
    Kim, Hyun-Mook
    Kim, Yong-Kwon
    Cho, Yong-Sang
    ADVANCED NONDESTRUCTIVE EVALUATION I, PTS 1 AND 2, PROCEEDINGS, 2006, 321-323 : 804 - 807