Magnetically suspended centrifugal blood pump with a self bearing motor

被引:22
|
作者
Masuzawa, T [1 ]
Onuma, H [1 ]
Kim, SJ [1 ]
Okada, Y [1 ]
机构
[1] Ibaraki Univ, Fac Engn, Dept Mech Engn, Hitachi, Ibaraki 3168511, Japan
关键词
D O I
10.1097/00002480-200207000-00019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A magnetically suspended centrifugal blood pump with a self bearing motor has been developed for long-term ventricular assistance. A rotor of the self bearing motor is actively suspended and rotated by an electromagnetic field without mechanical bearings. Radial position of the rotor is controlled actively, and axial position of the rotor is passively stable within the thin rotor structure. An open impeller and a semiopened impeller were examined to determine the best impeller structure. The outer diameter and height of the impeller are 63 and 34 mm, respectively. Both the impellers indicated similar pump performance. Single volute and double volute structures were also tested to confirm the performance of the double volute. Power consumption for levitation and radial displacement of the impeller with a rotational speed of 1,500 rpm were 0.7 W and 0.04 mm in the double volute, while those in the single volute were 1.3 W and 0.07 mm, respectively. The stator of the self bearing motor was redesigned to avoid magnetic saturation and improve motor performance. Maximum flow rate and pressure head were 9 L/min and 250 mm Hg, respectively. The developed magnetically suspended centrifugal blood pump is a candidate for an implantable left ventricular assist device.
引用
收藏
页码:437 / 442
页数:6
相关论文
共 50 条
  • [31] More than 1 year continuous operation of a centrifugal pump with a magnetically suspended impeller
    Nojiri, C
    Kijima, T
    Maekawa, J
    Horiuchi, K
    Kido, T
    Sugiyama, T
    Mori, T
    Sugiura, N
    Asada, T
    Shimane, H
    Nishimura, K
    Ban, T
    Akamatsu, T
    Ozaki, T
    Ito, H
    Suzuki, M
    Akutsu, T
    ASAIO JOURNAL, 1997, 43 (05) : M548 - M552
  • [33] Control of the pressure flow relationship with a magnetically suspended centrifugal pump in a chronic animal experiment
    Nishimura, K
    Tsukiya, T
    Akamatsu, T
    Kono, S
    Yamada, T
    Ban, T
    ASAIO JOURNAL, 1997, 43 (05) : M553 - M556
  • [34] In vivo testing of a magnetically suspended centrifugal pump designed for long-term use
    Yamada, T
    Nishimura, K
    Akamatsu, T
    Tsukiya, T
    Park, CH
    Kono, S
    Matsuda, K
    Ban, T
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (10): : 562 - 569
  • [35] In vivo testing of a magnetically suspended centrifugal pump designed for long-term use
    Department of Cardiovascular Surgery, Kyoto University of Medicine, 54 Shougoin Kawara-cho, Sakyo-ku, Kyoto 606, Japan
    INT. J. ARTIF. ORGANS, 10 (562-569):
  • [36] A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head
    Hijikata, Wataru
    Shinshi, Tadahiko
    Asama, Junichi
    Li, Lichuan
    Hoshi, Hideo
    Takatani, Setsuo
    Shimokohbe, Akira
    ARTIFICIAL ORGANS, 2008, 32 (07) : 531 - 540
  • [37] Control of centrifugal blood pump based on the motor current
    Iijima, T
    Inamoto, T
    Nogawa, M
    Takatani, S
    ARTIFICIAL ORGANS, 1997, 21 (07) : 655 - 660
  • [38] Disposable magnetically levitated centrifugal blood pump: Design and in vitro performance
    Hoshi, H
    Asama, J
    Shinshi, T
    Ohuchi, K
    Nakamura, M
    Mizuno, T
    Arai, H
    Shimokohbe, A
    Takatani, S
    ARTIFICIAL ORGANS, 2005, 29 (07) : 520 - 526
  • [39] Axial type self-bearing motor for axial flow blood pump
    Okada, Y
    Masuzawa, T
    Matsuda, KI
    Ohmori, K
    Yamane, T
    Konishi, Y
    Fukahori, S
    Ueno, S
    Kim, SJ
    ARTIFICIAL ORGANS, 2003, 27 (10) : 887 - 891
  • [40] HeartQuest ventricular assist device magnetically levitated centrifugal blood pump
    Bearnson, GB
    Jacobs, GB
    Kirk, J
    Khanwilkar, PS
    Nelson, KE
    Long, JW
    ARTIFICIAL ORGANS, 2006, 30 (05) : 339 - 346