Real Time Deconvolution of In-Vivo Ultrasound Images

被引:11
|
作者
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
关键词
D O I
10.1109/ULTSYM.2013.0008
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The axial resolution in medical ultrasound is directly linked to the emitted ultrasound frequency, which, due to tissue attenuation, is selected based on the depth of scanning. The resolution is determined by the transducers impulse response, which limits the attainable resolution to be between one and two wavelengths. This can be improved by deconvolution, which increase the bandwidth and equalizes the phase to increase resolution under the constraint of the electronic noise in the received signal. A fixed interval Kalman filter based deconvolution routine written in C is employed. It uses a state based model for the ultrasound pulse and can include a depth varying pulse and spatially varying signal-to-noise ratio. An autoregressive moving average (ARMA) model of orders 8 and 9 is used for the pulse, and the ARMA parameters are determined as a function of depth using a minimum variance algorithm using averaging over several RF lines. In vivo data from a 3 MHz mechanically rotating probe is used and the received signal is sampled at 20 MHz and 12 bits. In-vivo data acquired from a 16th week old fetus is used along with a scan from the liver and right kidney of a 27 years old male. The axial resolution has been determined from the in-vivo liver image using the auto-covariance function. From the envelope of the estimated pulse the axial resolution at Full-Width-Half-Max is 0.581 mm corresponding to 1.13 lambda at 3 MHz. The algorithm increases the resolution to 0.116 mm or 0.227 lambda corresponding to a factor of 5.1. The basic pulse can be estimated in roughly 0.176 seconds on a single CPU core on an Intel i5 CPU running at 1.8 GHz. An in-vivo image consisting of 100 lines of 1600 samples can be processed in roughly 0.1 seconds making it possible to perform real-time deconvolution on ultrasound data by using dual or quad core CPUs for frame-rates of 20-40 Hz.
引用
收藏
页码:29 / 32
页数:4
相关论文
共 50 条
  • [21] STUDY OF IN-VIVO PULMONARY CAPILLARY EXCHANGE BY NUMERICAL DECONVOLUTION
    NEUFELD, GR
    MARSHALL, BE
    FEDERATION PROCEEDINGS, 1972, 31 (02) : A366 - &
  • [22] Development of a novel instrument for ex-vivo and in-vivo real-time analysis
    Fournier, Isabelle
    Fatou, Benoit
    Wisztorski, Maxence
    Focsa, Cristian
    Ziskind, Michael
    Salzet, Michel
    JOURNAL OF BIOTECHNOLOGY, 2015, 208 : S10 - S10
  • [23] Evaluation of a Real Time Tumour Autocontouring Algorithm Using In-Vivo Lung MR Images with Various Contrast to Noise Ratios
    Yip, E.
    Yun, J.
    Gabos, Z.
    Wachowicz, K.
    Rathee, S.
    Fallone, B.
    MEDICAL PHYSICS, 2012, 39 (06) : 3687 - 3687
  • [24] Speech synthesis from real time ultrasound images of the tongue
    Denby, B
    Stone, M
    2004 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOL I, PROCEEDINGS: SPEECH PROCESSING, 2004, : 685 - 688
  • [25] A real time speckle noise cleaning filter for ultrasound images
    Mazumdar, B.
    Mediratta, A.
    Bhattacharyya, J.
    Banerjee, S.
    19TH IEEE INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2006, : 341 - +
  • [26] Real-time analysis of ultrasound images using GPU
    Eidheim, OC
    Skjermo, J
    Aurdal, L
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 284 - 289
  • [27] Interactive rendering of real-time volumetric ultrasound images
    Bredthauer, GR
    von Ramm, OT
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, 2004, : 524 - 526
  • [28] Real-time video transmission of ultrasound images to an iPhone
    Liteplo A.S.
    Noble V.E.
    Attwood B.
    Critical Ultrasound Journal, 2010, 1 (3) : 105 - 110
  • [29] Robust real-time instrument tracking in ultrasound images
    Ortmaier, T
    Vitrani, MA
    Morel, G
    Pinault, S
    MEDICAL IMAGING 2005: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2005, 5750 : 170 - 177
  • [30] Determination of real time in-vivo cartilage contact deformation in the ankle joint
    Li, Guoan
    Wan, Lu
    Kozanek, Michall
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 541 - 542