Selecting infusion devices for use in ambulatory care

被引:22
|
作者
Schleis, TG [1 ]
Tice, AD [1 ]
机构
[1] UNIV WASHINGTON,SCH MED,DEPT INFECT DIS,SEATTLE,WA
关键词
administration; ambulatory care; costs; devices; dosage; drug administration; economics; health care; injections; patient care; reimbursement;
D O I
10.1093/ajhp/53.8.868
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Intravenous infusion devices commonly used in home care and ambulatory care settings are reviewed and factors to consider in selecting a device are suggested. The type of therapy to be administered, the patient or caregiver's ability to understand and carry out instructions, staff time required for patient teaching and drug and device preparation, drug stability, frequency of doses, reservoir volume, control of flow rate, type of venous access, cost and availability of devices and supplies, and reimbursement should be considered. Cost-effectiveness of a device can be evaluated only by analyzing all of the costs associated with administering a medication. Decisions must be based on an individual agency's needs, but usually one type of single-dose infuser and one brand of electronic ambulatory-care infusion pump can meet the needs of most of an agency's patients. For patients self-administering up to four doses per day, appropriate methods may include slow intravenous injection (i.v. push), infusion from minibags and tubing, and the use of elastomeric infusers, electronic or mechanical syringe pumps, or a new device based on infusion across a bioelectric membrane. Some of these types of infusers can also be used for continuous infusion. Syringe pumps are reliable and affordable and control infusion rates well, but infusion volume is limited and these devices must be recovered, cleaned, and tested between patients. Although elastomeric pumps may have higher price tags than other devices, they are simple for patients to use and dispose of. While elastomeric devices have tubing permanently attached, the disposable tubing of some other devices is detachable and can be reused if institutional policy permits. Electronic ambulatory-care infusion pumps can meet a wide range of infusion requirements. They vary in size, weight, ability to detect occlusions, features, and reliability. All use proprietary infusion sets, but the costs of sets and disposable supplies vary. Some pumps can be used for a single infusion mode, such as patient-controlled analgesia (PCA); others offer two or more modes (for example, continuous, intermittent, and PCA). ''Multi-channel'' pumps can be used for simultaneous infusion of up to four medications; the rate of each infusion is programmed separately, and some multichannel devices offer multiple infusion modes. Some can be programmed remotely by telephone. Before an agency decides on a pump, it can investigate current users' and rental firms' experiences with the device. Also, all relevant personnel should try programming the device. Determining which devices to use requires a comparison of features that are pertinent to the particular agency or institution and a cost analysis that considers acquisition, reimbursement, patient training time, and the cost of disposable supplies.
引用
收藏
页码:868 / 877
页数:10
相关论文
共 50 条
  • [21] USE REVIEW OF INTRAVENOUS-INFUSION DEVICES
    KILARSKI, DJ
    SCHNEIDER, PJ
    TEIL, SM
    LEMAY, AP
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1981, 38 (10): : 1517 - 1518
  • [22] The Mixed Blessings of Smart Infusion Devices and Health Care IT
    Nemeth, Christopher P.
    Brown, Jeff
    Crandall, Beth
    Fallon, Corey
    MILITARY MEDICINE, 2014, 179 (08) : 4 - 10
  • [23] Partnerships for establishing a hospital-based ambulatory care infusion center
    Bryant-Wimp, J
    Liebert, L
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 1999, 56 (19) : 1974 - 1977
  • [24] SELECTING PATIENTS FOR AMBULATORY SURGERY
    DAVIS, JE
    SUGIOKA, K
    INFECTIONS IN SURGERY, 1990, 9 (06): : 34 - &
  • [25] NURSE LIAISON: BRIDGING THE GAP IN THE CARE CONTINUUM FOR AMBULATORY INFUSION PATIENTS
    Jellen, Sandy
    Lacatus, Gabriela
    Nguyen, Diana T.
    Sacco, Assuntina G.
    ONCOLOGY NURSING FORUM, 2022, 49 (02) : E120 - E120
  • [26] Temperature profiles of antibiotic-containing elastomeric infusion devices used by ambulatory care patients (vol 74, pg 992, 2017)
    Docherty, Toni
    Montalto, Michael
    Leslie, Joni
    Niblett, Suzanne
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2017, 74 (15) : 1122 - 1122
  • [27] Effectiveness and efficiency for ambulatory care assisted by mobile technological devices
    Zerth, J.
    Besser, J.
    Reichert, A.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 1075 - 1078
  • [28] SEX-DIFFERENCES IN USE OF AMBULATORY CARE
    ZEMP, E
    SOZIAL-UND PRAVENTIVMEDIZIN, 1984, 29 (4-5): : 180 - 182
  • [29] USE OF GENERIC PARAMETERS TO CLASSIFY AMBULATORY CARE
    HUNT, VB
    HARBERG, JK
    FRYBACK, DG
    ANDERSON, T
    NOREN, J
    CLINICAL RESEARCH, 1984, 32 (02): : A649 - A649
  • [30] Ensuring safe and economical use of elastomeric infusion devices
    Pepin, Jodie L.
    Dasta, Joseph F.
    New, Melanie
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2011, 68 (24) : 2330 - 2331