Choice of Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Impacts Hemodynamics Differently According to Aortic Annular Size

被引:34
|
作者
Rogers, Toby [1 ,2 ]
Steinvil, Arie [1 ]
Gai, Jiaxiang [1 ]
Torguson, Rebecca [1 ]
Koifman, Edward [1 ]
Kiramijyan, Sarkis [1 ]
Negi, Smita [1 ]
Lee, Sang Yeub [1 ]
Okubagzi, Petros [1 ]
Satler, Lowell F. [1 ]
Ben-Dor, Itsik [1 ]
Pichard, Augusto D. [1 ]
Waksman, Ron [1 ]
机构
[1] MedStar Washington Hosp Ctr, Sect Intervent Cardiol, Washington, DC 20010 USA
[2] NHLBI, Cardiovasc & Pulm Branch, Div Intramural Res, NIH, Bldg 10, Bethesda, MD 20892 USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2017年 / 119卷 / 06期
关键词
PARTNER TRIAL; IN-VITRO; REPLACEMENT; OUTCOMES; IMPLANTATION; PERFORMANCE; STENOSIS;
D O I
10.1016/j.amjcard.2016.11.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We sought to determine whether balloon-expandable valve (BEV) and self-expanding valve (SEV) affect valve hemodynamics differently according to native aortic annulus size. Transcatheter aortic valve replacement can achieve superior prosthetic valve hemodynamics compared with surgical aortic valve replacement, particularly in patients with small aortic annulus. One hundred ninety-three consecutive transcatheter aortic valve replacement patients were grouped into tertiles defined by computed tomography derived aortic annulus systolic perimeter. The predischarge echocardiogram was analyzed for prosthetic valve hemodynamics. Tertile perimeter cutoffs were 73 and 80 mm. STS score decreased as annulus size increased (7.8% vs 7.6% vs 6.0%, p <= 0.05 for small, medium, and large annulus, respectively). In patients with small aortic annulus, SEV was associated with significantly higher dimensionless index (0.64 vs 0.53, p = 0.02) and lower peak velocity (1.8 vs 2.4 m/sec, p <0.001) and a trend toward lower mean gradient (7.5 vs 10.0 mm Hg, p = 0.07) compared with BEV. These differences were attenuated and absent in patients with medium and large annulus, respectively. Few patients had moderate/severe paravalvular leak, with no association with valve type or annulus size. There was no difference in mortality between tertiles or valve type at 30 days or 1 year. There was no association between aortic annulus perimeter and 1-year mortality by univariate analysis (hazard ratio 1.00, 95% CI 0.95 to 1.05, p = 0.86) or multivariate analysis (hazard ratio 1.02, 95% CI 0.95 to 1.09, p = 0.60). In conclusion, SEV hemodynamics was superior to BEV in patients with small aortic annulus. This difference was diminished in patients with larger aortic annulus. This study highlights the importance of valve selection in patients with small aortic annulus. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:900 / 904
页数:5
相关论文
共 50 条
  • [1] Choice of balloon-expandable versus self-expanding transcatheter aortic valve impacts hemodynamics differently according to aortic annulus size
    Waksman, R.
    Rogers, T.
    Steinvil, A.
    Torguson, R.
    Gai, J.
    Koifman, E.
    Kiramijyan, S.
    Satler, L.
    Ben-Dor, I.
    Pichard, A.
    EUROPEAN HEART JOURNAL, 2016, 37 : 559 - 560
  • [3] Supra-Annular Self-Expanding Versus Balloon-Expandable Valves for Valve-in-Valve Transcatheter Aortic Valve Replacement
    Ahmad, Danial
    Sa, Michel Pompeu
    Yousef, Sarah
    Brown, James A.
    Doshi, Nandini
    Kliner, Dustin E.
    Serna-Gallegos, Derek
    Wang, Yisi
    Thoma, Floyd
    Toma, Catalin
    Makani, Amber
    Hasan, Irsa
    West, Dave
    Sultan, Ibrahim
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 231 : 55 - 61
  • [5] Self-expanding or balloon-expandable transcatheter aortic valve replacement in a German comparison
    Oettinger, V.
    Hilgendorf, I.
    Wolf, D.
    Rilinger, J.
    Stachon, P.
    Kaier, K.
    Zehender, M.
    Westermann, D.
    Von Zur Muehlen, C.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [6] Comparison of outcomes using balloon-expandable versus self-expanding transcatheter prostheses according to the extent of aortic valve calcification
    Won-Keun Kim
    Johannes Blumenstein
    Christoph Liebetrau
    Andreas Rolf
    Luise Gaede
    Arnaud Van Linden
    Mani Arsalan
    Mirko Doss
    Jan G. P. Tijssen
    Christian W. Hamm
    Thomas Walther
    Helge Möllmann
    Clinical Research in Cardiology, 2017, 106 : 995 - 1004
  • [7] Comparison of outcomes using balloon-expandable versus self-expanding transcatheter prostheses according to the extent of aortic valve calcification
    Kim, Won-Keun
    Blumenstein, Johannes
    Liebetrau, Christoph
    Rolf, Andreas
    Gaede, Luise
    Van Linden, Arnaud
    Arsalan, Mani
    Doss, Mirko
    Tijssen, Jan G. P.
    Hamm, Christian W.
    Walther, Thomas
    Moellmann, Helge
    CLINICAL RESEARCH IN CARDIOLOGY, 2017, 106 (12) : 995 - 1004
  • [8] New CENTERA Transcatheter Aortic Valve Best of the Balloon-Expandable and Self-Expanding Valve Worlds?
    Yeung, Alan C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (07) : 681 - 683
  • [9] Balloon-expandable versus self-expanding transcatheter aortic valve replacement: a comparison and evaluation of current findings
    Costa, Giuliano
    Criscione, Enrico
    Reddavid, Claudia
    Barbanti, Marco
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2020, 18 (10) : 697 - 708
  • [10] Hemodynamics of self-expanding versus balloon-expandable transcatheter heart valves in relation to native aortic annulus anatomy
    Schmidt, Sarah
    Fortmeier, Vera
    Ludwig, Sebastian
    Wienemann, Hendrik
    Koerber, Maria Isabel
    Lee, Samuel
    Meertens, Max
    Macherey, Sascha
    Iliadis, Christos
    Kuhn, Elmar
    Eghbalzadeh, Kaveh
    Bleiziffer, Sabine
    Baldus, Stephan
    Schofer, Niklas
    Rudolph, Tanja Katharina
    Adam, Matti
    Mauri, Victor
    CLINICAL RESEARCH IN CARDIOLOGY, 2022, 111 (12) : 1336 - 1347