Numerical study on the thermal buoyant flow stratification in tunnel fires with longitudinal imposed airflow: Effect of an upstream blockage

被引:26
|
作者
Gannouni, Soufien [1 ]
Zinoubi, Jamil [2 ]
Ben Maad, Rejeb [1 ]
机构
[1] Univ Tunis El Manar, Fac Sci Tunis, Dept Phys, Lab Energizing & Thermal & Mass Transfer, Tunis 2092, Tunisia
[2] Univ Tunis El Manar, Preparatory Inst Engn Studies El Manar, Tunis 2092, Tunisia
关键词
Tunnel fire; Thermal stratification; Vehicular obstruction; Longitudinal imposed airflow; FDS; VENTILATION;
D O I
10.1016/j.ijthermalsci.2018.10.041
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper is focused on the thermal buoyant flow stratification, generated by fire that occurred in a tunnel congested by an obstacle simulating a vehicle. The obstacle occupies about 0.31% of the tunnel cross section and is located at different distances from the floor. This case is considered for two main reasons: the first is that the remaining vehicles blocked upstream of the heat source cause a partial obstruction, the second reason is that the vehicle bottom actually has a certain distance from the tunnel floor. The obtained results showed that the increase of the forced airflow velocity has for results a loss of stratification. The obstruction existence effect in tunnel is reflected by smoke flow destratification upstream of the heat source fire. However, this effect is compensated downstream of the fire and there has been an improvement in the smoke flow stratification contrary to the case where the tunnel would be empty.
引用
收藏
页码:230 / 242
页数:13
相关论文
共 50 条
  • [41] Experimental study on the effect of lateral concentrated smoke extraction on smoke stratification in the longitudinal ventilated tunnel
    Tang, Fei
    Zhu, Yuantao
    Chen, Lei
    FIRE AND MATERIALS, 2020, 44 (07) : 1004 - 1012
  • [42] Numerical Study on Coupled Smoke Control Using Longitudinal Ventilation and Naturally Ventilated Shafts during Fires in a Road Tunnel
    Yao, Yongzheng
    Wang, Yintong
    Chen, Liang
    Ren, Fei
    Shi, Congling
    FIRE-SWITZERLAND, 2023, 6 (03):
  • [43] Thermal smoke back-layering flow length with ceiling extraction at upstream side of fire source in a longitudinal ventilated tunnel
    Tang, F.
    Li, L. J.
    Mei, F. Z.
    Dong, M. S.
    APPLIED THERMAL ENGINEERING, 2016, 106 : 125 - 130
  • [44] Numerical study on the axisymmetric state in spherical Couette flow under unstable thermal stratification
    Inagaki, Taishi
    Itano, Tomoaki
    Sugihara-Seki, Masako
    ACTA MECHANICA, 2019, 230 (10) : 3499 - 3509
  • [45] Numerical study on the axisymmetric state in spherical Couette flow under unstable thermal stratification
    Taishi Inagaki
    Tomoaki Itano
    Masako Sugihara-Seki
    Acta Mechanica, 2019, 230 : 3499 - 3509
  • [46] Numerical study on the flow characteristics and smoke temperature evolution under double fires condition with a metro train in tunnel
    Ren, Fei
    Shi, Congling
    Li, Jian
    Che, Honglei
    Xu, Xuan
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 114 (114)
  • [47] A numerical study on the effect of thermal and charge stratification on the HCCI natural gas engine
    Pourfallah, Mohsen
    Armin, Mahbod
    Ranjbar, Ali Akbar
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2021, 42 (12) : 1386 - 1395
  • [48] NUMERICAL STUDY OF THE EFFECT OF INLET GEOMETRY ON STRATIFICATION IN THERMAL-ENERGY STORAGE
    GHAJAR, AJ
    ZURIGAT, YH
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 1991, 19 (01) : 65 - 83
  • [49] Brine-water experimental study on the propagation of stratified smoke flow in tunnel fires under subcritical longitudinal ventilation
    Du, Tao
    Yu, Haoyue
    Lu, Xianyuan
    Yang, Dong
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 138
  • [50] Thermal buoyant smoke back-layering flow length in a longitudinal ventilated tunnel with ceiling extraction at difference distance from heat source
    Chen, L. F.
    Hu, L. H.
    Zhang, X. L.
    Zhang, X. Z.
    Zhang, X. C.
    Yang, L. Z.
    APPLIED THERMAL ENGINEERING, 2015, 78 : 129 - 135