Considerations on contactless conductivity detection in capillary electrophoresis

被引:1
|
作者
Baltussen, E
Guijt, RM
van der Steen, G
Laugere, F
Baltussen, S
van Dedem, GWK
机构
[1] Delft Univ Technol, Kluyver Inst Biotechnol, Lab Analyt Biotechnol, Fac Sci Appl, NL-2628 BC Delft, Netherlands
[2] Delft Univ Technol, Fac ITS ET, DIMES Elect Instrumentat Lab, NL-2628 BC Delft, Netherlands
[3] Delft Univ Technol, Fac Sci Appl, NL-2628 BC Delft, Netherlands
关键词
capillary electrophoresis; contactless conductivity detection; peptides;
D O I
10.1002/1522-2683(200209)23:17<2888::AID-ELPS2888>3.0.CO;2-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nearly all analyses by capillary electrophoresis (CE) are performed using optical detection, utilizing either absorbance or (laser-induced) fluorescence. Though adequate for many analytical problems, in a large number of cases, e.g., involving non-UV-absorbing compounds, these optical detection methods fall short. Indirect optical detection can then still provide an acceptable means of detection, however, with a strongly reduced sensitivity. During the past few years, contactless conductivity detection (CCD) has been presented as a valuable extension to optical detection techniques. It has been demonstrated that with CCD detection limits comparable, or even superior, to (indirect) optical detection can be obtained. Additionally, construction of the CCD around the CE capillary is straightforward and robust operation is easily obtained. Unfortunately, in the literature a large variety of designs and operating conditions for CCD were described. In this contribution, several important parameters of CCD are identified and their influence on, e.g., detectability and peak shape is described. An optimized setup based on a well-defined detection cell with three detection electrodes is presented. Additionally, simple and commercially available read-out electronics are described. The performance of the CCD-CE system was demonstrated for the analysis of peptides. Detection limits at the mum level were obtained in combination with good peak shapes and an overall good performance and stability.
引用
收藏
页码:2888 / 2893
页数:6
相关论文
共 50 条
  • [31] Determination of salbutamol sulfate in medicaments by capillary electrophoresis with contactless conductivity detection
    Chen Changguo
    Li Hong
    Fan Yujing
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (02) : 137 - 140
  • [32] Pushing the Limits of Capacitively Coupled Contactless Conductivity Detection for Capillary Electrophoresis
    Li, Lin
    Ren, Dou-Dou
    Zhang, Peng-Yu
    Song, Yun-Peng
    Li, Tang-Xiu
    Gao, Ming-Hui
    Xu, Jia-Nan
    Zhou, Lei
    Zeng, Zhi-Cong
    Pu, Qiaosheng
    ANALYTICAL CHEMISTRY, 2024, 96 (25) : 10356 - 10364
  • [33] A miniaturized analysis system based on capillary electrophoresis and contactless conductivity detection
    Lichtenberg, J
    Verpoorte, E
    de Rooij, NF
    TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2001, : 408 - 411
  • [34] Contactless conductivity detector for microchip capillary electrophoresis
    Pumera, M
    Wang, J
    Opekar, F
    Jelínek, I
    Feldman, J
    Löwe, H
    Hardt, S
    ANALYTICAL CHEMISTRY, 2002, 74 (09) : 1968 - 1971
  • [35] Contactless conductivity detector for capillary electrophoresis chip
    Liu, Xiao-Wei
    Zhang, Hai-Feng
    Shao, Xian-Hui
    Li, Ling
    Peng, Zhi-Cheng
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2009, 7 (02): : 123 - 126
  • [36] Contactless conductivity detector array for capillary electrophoresis
    Stojkovic, Marko
    Koenka, Israel Joel
    Thormann, Wolfgang
    Hauser, Peter C.
    ELECTROPHORESIS, 2014, 35 (04) : 482 - 486
  • [38] Quantification of plasma lactate concentrations using capillary electrophoresis with contactless conductivity detection
    Pormsila, Worapan
    Morand, Rejane
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    ELECTROPHORESIS, 2011, 32 (08) : 884 - 889
  • [39] Capillary electrophoresis with contactless conductivity detection for the determination of carnitine and acylcarnitines in clinical samples
    Pormsila, Worapan
    Morand, Rejane
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (13-14): : 921 - 926
  • [40] Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements
    Abad-Villar, EM
    Tanyanyiwa, J
    Fernández-Abedul, MT
    Costa-García, A
    Hauser, PC