Numerical Investigation of Temperature Distribution in a Water Cooling Tank under Natural Convection

被引:1
|
作者
Kusuma, Mukhsinun Hadi [1 ]
Sundari, Titik [2 ]
Antariksawan, Anhar Riza [1 ]
Ismarwanti, Sri [3 ]
Juarsa, Mulya [1 ]
Putra, Nandy [4 ]
Widodo, Surip [1 ]
Ardiyati, Tanti [5 ]
Subekti, Muhammad [1 ]
Artiani, Pungki Ayu [2 ]
机构
[1] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Nucl Reactor Technol & Safety, Tangerang Selatan 15314, Indonesia
[2] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Radioact Waste Technol, Tangerang Selatan 15314, Indonesia
[3] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Nucl Fuel Technol, Tangerang Selatan 15314, Indonesia
[4] Univ Indonesia, Dept OfMech Engn, Heat Transfer Lab, Kampus UI, Depok 16424, Indonesia
[5] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Nucl Facil Engn, Tangerang Selatan 15314, Indonesia
关键词
HEAT REMOVAL SYSTEM; PERFORMANCE; REACTOR; POOL;
D O I
10.1063/1.5086557
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
In a typical small modular reactor, an emergency cooling tank acts as additional safety feature that is intended to cope with an emergency situation. Water inside the cooling tank absorbs residual heat from the reactor core when an accident occurs through a system designed for that purpose. In the emergency cooling tank, a heat exchanger is used to transfer the heat from the core to the water coolant under natural convection. For studying this emergency cooling system, an experimental facility was designed, namely FASSIP-02. The objective of this study was to investigate the temperature distribution inside the water cooling tank under natural convection. The numerical code Fluent 6.3 and RELAP5 were used to investigate the heat transfer phenomena from the heat exchanger to the water cooling tank. The water cooling tank, which was one of the important components in simulating the emergency cooling tank, was made from carbon steel with length of 3100 nun, width of 1100 mm, and height of 2750 mm. The water with initial temperature of 300 K was tilled into the cooling tank as high as 2000 nun A U-shaped heat exchanger that was made from copper tube with inner diameter of 25.4 mm, outside diameter of 27.4 mm, length of 4200 nun, and thickness of 1 mill was inunersed in the cooling tank. The hot water with various temperatures of 343, 353, and 363 K was assumed to flow inside the heat exchanger, while the velocities of the hot water were varied from 0.05, 0.5, to I m/s. The simulation results obtained show that an increasing of temperature and velocity of the hot water inside the U-shaped heat exchanger resulted in increasing of heat transferred to the water and water temperature in the cooling tank. The natural single-phase convection affected the heat transfer.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Experimental and numerical investigation of the LiFePO4 battery cooling by natural convection
    Kalkan, Orhan
    Celen, Ali
    Bakirci, Kadir
    JOURNAL OF ENERGY STORAGE, 2021, 40 (40):
  • [12] Effect of cooling surface temperature on frosting phenomena under natural convection
    Ohkubo, Hidetoshi
    Matsumura, Masahiro
    Ueno, Masayuki
    Yamashita, Koji
    PROCEEDINGS OF THE ASME/JSME THERMAL ENGINEERING SUMMER HEAT TRANSFER CONFERENCE 2007, VOL 2, 2007, : 621 - 626
  • [13] Numerical study on natural convection in a ship cargo tank
    Sahin, K.
    Ergin, S.
    SUSTAINABLE DEVELOPMENT AND INNOVATIONS IN MARINE TECHNOLOGIES, 2020, 3 : 512 - 519
  • [14] Numerical simulation on natural convection and temperature distribution of supercritical water in a side-wall heated cavity
    Li, Yi
    Wang, Huibo
    Shi, Jinwen
    Cao, Changqing
    Jin, Hui
    JOURNAL OF SUPERCRITICAL FLUIDS, 2022, 181
  • [15] Numerical Simulation of Water Temperature Distribution in the Tank of ASHPWH with a Cylindrical Condenser
    Cai, Wei
    Gong, Xuemei
    Wang, Dandan
    PROCEEDINGS OF FIRST INTERNATIONAL CONFERENCE OF MODELLING AND SIMULATION, VOL I: MODELLING AND SIMULATION IN SCIENCE AND TECHNOLOGY, 2008, : 150 - 153
  • [16] Numerical Investigation Of transient Natural Convection In partitioned cavity filled with water
    Zemani-Kaci, Farah
    Sabeur-Bendehina, Amina
    MATERIALS & ENERGY I (2015) / MATERIALS & ENERGY II (2016), 2017, 139 : 340 - 345
  • [17] Numerical Simulation of WAAM Temperature Field Under Water Cooling
    Chen K.
    Wang X.
    Li Y.
    Chen Y.
    Du Y.
    Cailiao Daobao/Materials Reports, 2021, 35 (04): : 04165 - 04169
  • [18] Experimental and Numerical Investigation of the Effect of Water Cooling on the Temperature Distribution of Photovoltaic Modules Using Copper Pipes
    Shojaeefard, Mohammad Hassan
    Sakran, Noor Barzan
    Sharfabadi, Mohammad Mazidi
    Hussein, Omar A.
    Mohammed, Hussein A.
    ENERGIES, 2023, 16 (10)
  • [19] Numerical investigation of surface evaporation and thermocapillarity effects on natural convection within a contained fluid in cryogenic tank
    Rachedi, Kamel
    Ragueb, Haroun
    Boussaid, Mohammed
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2022, 214
  • [20] Numerical investigation of surface evaporation and thermocapillarity effects on natural convection within a contained fluid in cryogenic tank
    Rachedi, Kamel
    Ragueb, Haroun
    Boussaid, Mohammed
    Journal of Petroleum Science and Engineering, 2022, 214